Permit Review Detail
Review Status: Completed
Review Details: 3RD PARTY REVIEW-COMMERCIAL TI
Permit Number - T03CM05654
Review Name: 3RD PARTY REVIEW-COMMERCIAL TI
Review Status: Completed
Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
---|---|---|---|---|---|
12/18/2003 | EROSE1 | WWM | REVIEW | Needs Review | |
12/18/2003 | STANTEC | 3RD PARTY REVIEW-COMMERCIAL | REVIEW | Denied | SCOPE OF REVIEW: The scope of this review covers Architectural, Structural, Plumbing, Mechanical and Electrical. All features were checked only to the extent allowed by the submittal provided. All portions of the project are assumed to meet or will meet other departmental requirements, conditions and concerns before permit approval. ARCHITECTURAL: q Verify and correct the type of construction in the code information on Sheet AO. Currently the plan indicates that the construction type is "IB" which may be incorrect. City records indicate Type VB is the correct type of construction classification. q Sheet A1: The space is required to have separate restrooms for each sex. See IBC Section 2902.2 and revise plans accordingly. q Sheet A1: Provide description as to how accessibility is provided for each type of service provided. Are chairs at each station fixed or movable? If fixed, detail accessibility per ADA and ANSI A117.1-98. q Sheet A1: Dimension the side clearance from the water closet to the lavatory as 5' measured from the side wall to the lavatory. See ANSI A117.1-98, Figure 604.3.1. q Detail 3/A3: Position toilet paper dispenser in compliance with ANSI A117.1-98, Figure 604.7(a). Detail grab bar anchoring and structural support for the load requirements of ANSI A117.1-98 and ADA. STRUCTURAL: q Provide structural evaluation of roof structure for adequacy to support new roof mounted equipment. If modifications are required, provide calculations and details. MECHANICAL: q There are no mechanical comments to be addressed. PLUMBING: q There are no plumbing comments to be addressed. ELECTRICAL: q Sheet E1: Revise the smoke detection note on the floor plan to include compliance with the 2000 IMC Section 606. -End of Review- |
12/18/2003 | EROSE1 | WATER | REVIEW | Needs Review |
Final Status
Task End Date | Reviewer's Name | Type of Review | Description |
---|---|---|---|
12/18/2003 | ELAINE ROSE | OUT TO CUSTOMER | Completed |