Permit Review Detail
Review Status: Completed
Review Details: 3RD PARTY REVIEW-RESIDENTIAL
Permit Number - T03CM05614
Review Name: 3RD PARTY REVIEW-RESIDENTIAL
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 12/23/2003 | EROSE1 | WWM | REVIEW | Needs Review | |
| 12/23/2003 | ELAINE ROSE | ZONING | REVIEW | Needs Review | |
| 12/23/2003 | GP | 3RD PARTY REVIEW-COMMERCIAL | REVIEW | Denied | ARCHITECTURAL COMMENTS Sheet 2.0 1. Specify safety glazing for the 4020 window in the wall along the stairway. Ref. R308.4.9. 2. Notes at the first floor hall indicate stairs are to be constructed. Show the location of the stairs and handrail. Ref. R315. Sheet 4.0 1. Show where toedown detail 4/4.0 occurs at covered porch and landings. 2. Show the minimum concrete footing width for two story conventional light frame construction. Ref. R403.1. Sheet 6.0 1. Stair framing detail 2/6.0 shows riser dimensions that are not consistent with the plan callouts on Sheet 2.0. Coordinate plan dimensions with the detail. PLUMBING COMMENTS Sheet 7.0 1. HCS location is not consistent with the site plan. Coordinate the HCS location shown on the site plan with the plumbing drawings. MECHANICAL COMMENTS Sheet 8.0 1. Show path and termination of the kitchen exhaust hood. Ref. M1502. ELECTRICAL COMMENTS Sheet 9.0 1. Show the circuit number for the WP motion sensor. 2. The 40 amp water heater requires a #8 conductor. Ref. E3605.1. ENERGY COMMENTS Sheet 2 1. Note 14 states R-13 insulation is provided at exterior walls. Wall section 3/6.0 specifies R-19. Please clarify. |
| 12/23/2003 | EROSE1 | NPPO | REVIEW | Needs Review | |
| 12/23/2003 | EROSE1 | ENGINEERING | REVIEW | Needs Review |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 12/23/2003 | ELAINE ROSE | OUT TO CUSTOMER | Completed |