| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 04/13/2004 | MELISSA POULIN | WWM | REVIEW | Denied | Needs to show location/methoid of connection to public sewer with all easements and jt. use agreements if applicable. Needs WW 8th floor review. |
| 04/19/2004 | David Witt | BUILDING-RESIDENTIAL | REVIEW | Denied | PLAN CHECK COMMENTS - PROJECT #T03CM005530 4/20/04 3313 E. WATER ST. PLAN REVIEW FOR THE ABOVE REFERENCED STRUCTURE HAS BEEN COMPLETED. THIS LETTER REFLECTS COMMENTS TO BE ADDRESSED. IN ORDER TO FACILITATE A SHORTER BACK CHECK TIME, WE REQUEST THAT YOU PLEASE PROVIDE REVISED PLANS AND CALCULATIONS, HIGHLIGHTING ANY CHANGES, ALONG WITH A WRITTEN RESPONSE TO EACH OF THE NOTED ITEMS INDICATING ACTION TAKEN. SCOPE OF REVIEW: THE SCOPE OF THIS PLAN REVIEW COVERS ARCHITECTURAL, PLUMBING, MECHANICAL, MODEL ENERGY AND ELECTRICAL CODES. ALL CODE REFERENCES ARE TO THE 2000 IRC AND STATE PLUMBING CODE. ALL FEATURES WERE CHECKED ONLY TO THE EXTENT ALLOWED BY THE SUBMITTALS PROVIDED. ALL PORTIONS OF THIS PROJECT ARE ASSUMED TO MEET OR WILL MEET OTHER DEPARTMENTAL REQUIREMENTS, CONDITIONS AND CONCERNS BEFORE PERMIT APPROVAL. GENERAL REQUIREMENTS: 1. ALL PLANS SHALL BE LEGIBLE AND A SCALE NO SMALLER THAN ΒΌ INCH = 1-FOOT SHALL BE USED FOR ALL FLOOR PLANS, FRAMING PLANS AND ELEVATIONS. DETAILS &CROSS SECTIONS AT A MINIMUM 3/8 INCH = 1-FOOT SCALE. 2. ALL CORRECTIONS AND REVISIONS SHALL BE MADE ON THE ORIGINAL TRACINGS AND TWO NEW SETS OF PRINTS OR (1) SEPIA & (1) BLUE LINE SHALL BE RETURNED ALONG WITH ALL REDLINE PRINTS. 3. PEN OR PENCIL CORRECTIONS ON FINAL PRINTS WILL NOT BE ACCEPTABLE. TO AVOID DELAYS ENSURE ALL CORRECTIONS HAVE BEEN MADE, ARE COMPLETE AND HAVE BEEN COORDINATED ON ALL APPLICABLE DETAILS AND NOTES. SITE PLAN: 1. PROVIDE THE TWO APPROVED SITE PLAN AND SHOW THE REQUIRED 6', MAX., WALL ADJACENT 2522 N. EDITH. FOUNDATION PLANS: 1. THE SIMPSON "LSTHD8" HOLD-DOWN REQUIRES A #4 IN THE TOP OF THE FOUNDATION. FLOOR PLANS: 1. LABEL ALL ROOMS AND SPACES. SHOW ALL DOORS. SHOW ENTIRE FLOOR PLAN. STRUCTURAL PLANS: 1. PROVIDE A BEAM OVER LIVING ROOM OF APARTMENT #1 . 2. CO-ORDINATE THE BEAM SIZES, ON THE PLANS, ON THE FRAMING PLAN AND DETAIL C / 6 . 3. SPECIFY COMBINATION SYMBOL FOR THE GLULAMS. SECTIONS - DETAILS - MISC. NOTES: 1. SECTION A / 4 ; ILLUSTRATE THE WALLS SEPARATING THE TWO UNITS FROM EACH OTHER EXTENDING TO THE ROOF DECK. 2. 2 / 3 ; SHOULD THE "ABU44" BE AN "ABU66" FOR A 6 X 6 POST? 3. A / 6 ; R-13 IS THE LOWEST R-VALUE USED IN THE I.R.C.'s ENERGY CHAPTER 11 FOR OUR 2100 HEATING DEGREE DAY HERE IN TUCSON. THE "ENERGY CALCULATION" FORM SUBMITTED IS FOR ADDITIONS, NOT NEW PROJECTS. YOU MIGHT CONSIDER I.R.C.'s TABLE N1102.1 IN LIEU OF THE LONG FORM ENERGY CALCULATIONS. 4. PROVIDE A CROSS SECTION OF THE SITE WALL ADJACENT 2522 N. EDITH . 5. A / 6 ; PROVIDE 1-1/2" OF BEARING FOR THE RAFTER AND AN H2.5 OR A LEDGER WITH A JOIST HANGER. PLUMBING PLANS: 1. THE NEW FIXTURE CHART DIFFERS FROM THE RISER DIAGRAM. THE RISER DIAGRAM DIFFERS FROM THE PLAN. PLEASE CO-ORDINATE. WHAT IS "P5" ON THE RISER DIAGRAM? 2. THE PLUMBING NOTES SHOULD REFER TO THE UNIFORM PLUMBING CODE, NOT THE I.R.C. . MECHANICAL PLANS: 1. ANY EVAPORATIVE COOLERS OR A/C ? ELECTRICAL PLANS: 1. THE BASE BOARD HEATERS SHOULD BE ADDED TO THE LOAD CALCULATIONS AT 100% AFTER THE 40% REDUCTION OF THE OTHER LOADS. 2. THE WATER HEATERS ARE ON 30 AMP CIRCUITS BUT ONLY 3000 WATTS ARE USED ON THE LOAD CALCULATIONS. PLEASE CO-ORDINATE. 3. NOTE THAT LIGHT FIXTURES IN CLOTHES CLOSETS SHALL BE INSTALLED IN ACCORDANCE WITH E3903.11. MODEL ENERGY CODE: 1. PROVIDE ENERGY CALCULATIONS PER THE 1998 IECC, OR COMPLY WITH IRC CHAPTER 11. I.R.C.TABLE N1102.1 IS A TABLE THAT MAY BE USED INSTEAD OF THE LONG FORM ENERGY CALCULATIONS. TUCSON USES 2100 HDD. 2. CALL OUT ON THE PLANS THE "R" VALUES OF INSULATION, AS WELL AS THE "U" VALUES OF THE WINDOWS AND DOORS IN CONFORMANCE WITH THE ENERGY CALCULATIONS PROVIDED. IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT YOUR ASSIGNED PLANS EXAMINER: DAVE WITT @ 791-5550 EXT. 1110 NOTE: AS OF 2-02-01 THE CITY OF TUCSON HAS ADOPTED THE 2000 IRC EXCEPT FOR THE PLUMBING PORTION WHICH IS THE STATE PLUMBING CODE. ALL MODEL PLANS SHALL BE REFERENCE TO THE PREVIOUSLY MENTIONED CODES. |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 04/26/2004 | EGRANT1 | OUT TO CUSTOMER | Completed |
| 04/21/2004 | ANGIE SHOFFSTALL | REJECT SHELF | Completed |