Permit Review Detail
Review Status: Completed
Review Details: RESIDENTIAL BLDG/WWM
Permit Number - T03CM05458
Review Name: RESIDENTIAL BLDG/WWM
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 11/19/2003 | GERRY KOZIOL | WWM | REVIEW | Approved | |
| 12/15/2003 | David Witt | BUILDING-RESIDENTIAL | REVIEW | Denied | PLAN CHECK COMMENTS - PROJECT #T03CM05458 12/16/03 801 N. JERRIE AVE. PLAN REVIEW FOR THE ABOVE REFERENCED STRUCTURE HAS BEEN COMPLETED. THIS LETTER REFLECTS COMMENTS TO BE ADDRESSED. IN ORDER TO FACILITATE A SHORTER BACK CHECK TIME, WE REQUEST THAT YOU PLEASE PROVIDE REVISED PLANS AND CALCULATIONS, HIGHLIGHTING ANY CHANGES, ALONG WITH A WRITTEN RESPONSE TO EACH OF THE NOTED ITEMS INDICATING ACTION TAKEN. SCOPE OF REVIEW: THE SCOPE OF THIS PLAN REVIEW COVERS ARCHITECTURAL, PLUMBING, MECHANICAL, MODEL ENERGY AND ELECTRICAL CODES. ALL CODE REFERENCES ARE TO THE 2000 IRC AND STATE PLUMBING CODE. ALL FEATURES WERE CHECKED ONLY TO THE EXTENT ALLOWED BY THE SUBMITTALS PROVIDED. ALL PORTIONS OF THIS PROJECT ARE ASSUMED TO MEET OR WILL MEET OTHER DEPARTMENTAL REQUIREMENTS, CONDITIONS AND CONCERNS BEFORE PERMIT APPROVAL. GENERAL REQUIREMENTS: 1. ALL PLANS SHALL BE LEGIBLE AND A SCALE NO SMALLER THAN ¼ INCH = 1-FOOT SHALL BE USED FOR ALL FLOOR PLANS, FRAMING PLANS AND ELEVATIONS. DETAILS &CROSS SECTIONS AT A MINIMUM 3/8 INCH = 1-FOOT SCALE. 2. ALL CORRECTIONS AND REVISIONS SHALL BE MADE ON THE ORIGINAL TRACINGS AND TWO NEW SETS OF PRINTS OR (1) SEPIA & (1) BLUE LINE SHALL BE RETURNED ALONG WITH ALL REDLINE PRINTS. 3. PEN OR PENCIL CORRECTIONS ON FINAL PRINTS WILL NOT BE ACCEPTABLE. TO AVOID DELAYS ENSURE ALL CORRECTIONS HAVE BEEN MADE, ARE COMPLETE AND HAVE BEEN COORDINATED ON ALL APPLICABLE DETAILS AND NOTES. FOUNDATION PLANS: 1. PROVIDE HOLD DOWNS RATED AT 3000 LBS. TENSILE STRENGTH AT BOTH LOWER CORNERS OF BRACED WALL PANELS LESS THAN 4 FT. WIDE FOR TWO STORY CONDITIONS PER R610.10.6 AND PLEASE SPECIFY THE SIZE AND LOCATION OF THE PANEL'S ANCHOR BOLTS. 2. THE MINIMUM FOOTING WIDTH IS 19" FOR A TWO STORY WITH OUT A SOIL REPORT TO JUSTIFY A SOIL BEARING CAPACITY GREATER THAN 1500 PSF PER TABLE R403.1. FLOOR PLANS: 1. PLEASE PROVIDE THE FLOOR PLAN OF THE ADJACENT ROOM UPSTAIRS. ( DOORS & WINDOWS ) 2. SAFETY GLASS IS REQUIRED WITHIN 24" OF THE DOOR AND ADJACENT THE STAIRS. SEE R308. 3. NOTE THAT BATHTUB AND SHOWER ENCLOSURES SHALL BE FINISHED PER p2710 WITH CERAMIC TILE, OR A LISTED ENCLOSURE, TO A HEIGHT OF 72" ABOVE THE DRAIN PER R702.4 AND R307.2 4. LOCATE AND IDENTIFY SHEAR WALL TYPES AND LOCATIONS. PROVIDE NAILING SCHEDULE. STRUCTURAL PLANS: 1. DETAIL ALL SHEAR CONNECTIONS FROM THE FOUNDATION TO THE ROOF PLYWOOD. 2. PROVIDE STAIRWAY CONNECTION DETAILS AND STRINGER SIZES. PRE-FABRICATED METAL STAIR SHALL HAVE MANUFACTURER'S SPECIFICATIONS ATTACHED TO PLANS. ELEVATIONS: 1. SHOW CALCULATION OF ATTIC VENTILATION AREA IN COMPLIANCE WITH R806.2. NOTE LOCATION OF ALL VENTS NEEDED TO COMPLY. 2. NOTE GLASS IN HAZARDOUS AREAS SHALL BE SAFETY GLASS PER R308.4. SECTIONS - DETAILS - MISC. NOTES: 1. SECTION A / 4 NOTES A RAFTER THAT DIFFERS FROM THE ROOF FRAMING PLAN. 2. 1,3,/ 5 ; PLEASE REFER TO TABLE 403.1 FOR THE MINIMUM FOOTING WIDTH. 3. 2/5 ; PROVIDE THE FOOTING WIDTH. 4. PLEASE ILLUSTRATE THE EXTERIOR SHEATHING. 5. T.J.I. PRO 250'S HAVE A 1 ¾" FLANGE. PLEASE SPECIFY A JOIST HANGER TO ACCOMMODATE THE DOUBLE T.J.I. 6. PLEASE NOTE THAT ½" G.W.B. ON CEILINGS FRAMED AT 24" IS REQUIRED TO BE SAG-RESISTANT. SEE TABLE R702.3.5 . 7. PROVIDE A DETAIL OR NOTE TO SHOW THE WALL SHEATHING ON A BRACED WALL PANEL ON THE FIRST FLOOR OF A TWO STORY IS REQUIRED ON BOTH SIDES OF THE WALL. SEE R602.10..6 . PLUMBING PLANS: 1. THE WATER SUPPLY AND DRAINAGE FIXTURE UNIT TABLES SHOULD BE IN ACCORD WITH THE U.P.C. 2. PLEASE SIZE THE DWV . 3. THE TUB DOESN'T APPEAR TO BE VENTED IN ACCORD WITH THE U.P.C. . PLEASE CLARIFY. SEE U.P.C. 905.2 & 905.3 . 4. PROVIDE THE SOURCE OF THE WATER. IF THE EXISTING DISTRIBUTION SYSTEM IS INVOLVED, PLEASE JUSTIFY THE DISTRIBUTION SYSTEM FROM THE POINT OF CONNECTION BACK TO THE METER. 5. PLUMBING PLAN NOTES / 8 ; THE UNIFORM PLUMBING CODE WITH STATE AMENDMENTS SHOULD BE THE CODE OF REFERENCE. 6. PLUMBING NOTE #24 ; PLEASE USE THE LENGTHS FROM THE U.P.C. MECHANICAL PLANS: 1. THE ADDITION MUST BE PROVIDED WITH HEATING CAPABLE OF MAINTAINING A ROOM TEMPERATURE OF 68 DEGREES AT A POINT 3' ABOVE THE FLOOR PER R303.6. ELECTRICAL PLANS: 1. NOTE ON PLANS: ELECTRICAL WORK SHALL COMPLY WITH CHAPTERS 33 - 42, 2000 IRC. PLEASE CORRECT THE CHAPTER 33 REFERENCE. 2. THE RECEPTACLE OUTLET PROVIDED ADJACENT TO THE BASIN IN EACH BATHROOM, PER E3801.6, IS REQUIREDTO BE ON A SEPARATE 20 AMP CIRCUIT, PER E3603.4. 3. NOTE THAT LIGHT FIXTURES IN CLOTHES CLOSETS SHALL BE INSTALLED IN ACCORDANCE WITH E3903.11. IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT YOUR ASSIGNED PLANS EXAMINER: DAVE WITT @ 791-5550 EXT. 1110 NOTE: AS OF 2-02-01 THE CITY OF TUCSON HAS ADOPTED THE 2000 IRC EXCEPT FOR THE PLUMBING PORTION WHICH IS THE STATE PLUMBING CODE. ALL MODEL PLANS SHALL BE REFERENCE TO THE PREVIOUSLY MENTIONED CODES. ADDITIONAL PLAN CHECK COMMENTS PLEASE PROVIDE THE SHOP DRAWINGS FOR THE CIRCULAR STAIRS. |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 12/17/2003 | LISA LESNY | OUT TO CUSTOMER | Completed |
| 12/16/2003 | ANGIE SHOFFSTALL | REJECT SHELF | Completed |