Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit Number: T03CM05240
Parcel: 11501155P

Address:
2251 N 6TH AV

Review Status: Completed

Review Details: SITE

Permit Number - T03CM05240
Review Name: SITE
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
11/21/2003 Blanca Espino ENGINEERING REVIEW Denied DATE: November 25, 2003
ACTIVITY NUMBER: T03CM05240
PROJECT NAME: Warehouse Bldg. on 6th Ave.
PROJECT ADDRESS: 2251 N. 6th Ave.
PROJECT REVIEWER: Blanca Espino, Engineering Associate

Resubmittal Required: Site Plan

The following items must be revised or added to the plan. Please include a response letter with the next submittal that states how all comments have been addressed.

Site Plan
1. Indicate property description. D.S. 2-02.2.1.A.2

2. Indicate project address. D.S. 2-02.2.1.A.3

3. Indicate proposed buildings roof slope, downspouts and sidewalk scuppers.. Indicate a dimension detail of downspout and scuppers. D.S. 2-02.2.1.A.6

4. If applicable, indicate location, type, size and height of existing and proposed signage. D.S. 2-02.2.1.A.13

5. Place a note on the plan, "See Grading Plan T03BU02850 Sheet C2.1 for elevation data, cut and fill quantites, drainage patterns, FFE, Basis of Elevation, and Basis of Bearing." D.S. 2-02.2.1.A.16,17,23

6. Indicate if streets are Public or Private. D.S. 2-02.2.1.A.18

7. Dimensioned right-of-way, including any applicable Major Streets and Routes (MS&R) Plan right-of-way. D.S. 2-02.2.1.A.19

8. All easements of record must be graphically shown on the plan together with recording docket and page reference. D.S. 2-02.2.1.A.20

9. A container service area must have an inside clear dimension of ten (10) feet by ten (10) feet. The plan shows a ten foot outside dimension. Steel pipes are required between the container and the enclosures rear and side walls. D.S. 6-01.4.2.C

10. Curb returns are required on all ingress/egress from an MS&R street. Because 6th is an MS&R show curb returns. Minimum radius is 25 ft. Transportation Access Management Guidelines, p. 21,22
12/01/2003 Joseph Linville LANDSCAPE REVIEW Denied 1) City Engineer approval is required in order to locate up to 5' of the required street landscape border within the public in writing. Include written verification of any approvals received
with future submittals.

2) Page 94 of the Stormwater Detention/Retention Manual list Lleucophyllum as a species which should be avoided within the flood zone. Revise the basin planting plan to include a species more compatible with periodic inundation. DS 10-01.0

3) Per DS 10-01.4.3.1 basins three feet and greater are to have slopes no steeper that 4:1. Revise the plans as necessary.

4) Sheets C1.1, C.2.1, and L1.1 do not match regarding the location of the loading zone. Revise as necessary.

5) A native plant preservation plan is required. LUC 3.8
12/03/2003 JOE LINVILLE NPPO REVIEW Denied A native plant preservation plan is required. LUC 3.8
Plans will not be accepted for review without the required plans.
12/05/2003 MICHAEL ST. PAUL ZONING REVIEW Denied SITE PLAN TRANSMITTAL

TO: Development Services Department
Plans Coordination Office

FROM: Michael St.Paul FOR: Patricia Gehlen
Planning Technician Principal Planner

PROJECT:
T03CM05240
Warehouse
2251 North 6th Avenue
TRANSMITTAL: December 5, 2003
DUE DATE: December 3, 2003


COMMENTS: Please attach a response letter with the next submittal, which states how all Zoning Review Section comments regarding the Land Use Code and Development Standards were addressed.
CODE SECTION/
DEVELOPMENT
STANDARD

1. Please provide the legal description of the property and the address for this project on the site plan.
DS 2-02.2.1.2
DS 2-02.2.1.3
2. Please provide the dimension from the front of the building to the property along Sixth Avenue at the shortest point.
DS 2-02.2.1.6
3. The proposed parking calculations are for the Industrial Use Group. None of those uses are allowed within the C-2 zone. Clearly and correctly identify an appropriate proposed use, or use group, for this zone. Provide correct vehicle and bicycle calculations for the identified use.
DS 2-02.2.1.8
DS 2-02.2.1.9
DS 2-02.2.1.31
DS2-02.2.2.4
4. A pedestrian refuge is required between the building and the parking area access lane (PAAL) along the west (rear) side of the building. This pedestrian refuge must be connected to and integrated with the pedestrian circulation for the site.
DS 2-02.2.1.12
DS 2-08.4.1.B
DS 2-08.3.1
5. Please provide the location, type, size and height of any proposed signage.
DS 2-02.2.1.13
6. Please graphically depict all easements of record on the site plan with docket and page recording information.
DS 2-02.2.1.20
7. Please graphically depict any proposed lighting type and layout.
DS 2-02.2.1.25
8. Please note that any and all changes made to this Site Plan must also be made to the Landscape Plan, the Grading Plan and any additional sheet developed for this project.

9. All billboards must be removed prior to the issuance of any C of Os for this property.

10. Landscaping in the right-of-way requires specific approval from the City Engineer.

11. Please more clearly depict the plans for the vacated area, and provide the anticipated date of acquisition.

12. The number handicapped accessible parking until the use and related parking issues have been addressed.










If you have any questions about this transmittal, please call Michael St.Paul, (520) 791-5608 x1184.
12/05/2003 MICHAEL ST. PAUL HANDICAP-SITE REVIEW Denied See zoning comments.
12/08/2003 JIM EGAN FIRE REVIEW Approved

Final Status

Task End Date Reviewer's Name Type of Review Description
12/09/2003 TAMI ACHONG OUT TO CUSTOMER Completed
12/08/2003 ANGIE SHOFFSTALL REJECT SHELF Completed