Permit Review Detail
Review Status: Completed
Review Details: RESIDENTIAL BLDG/WWM
Permit Number - T03CM05223
Review Name: RESIDENTIAL BLDG/WWM
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 11/04/2003 | MELISSA POULIN | WWM | REVIEW | Approved | |
| 12/01/2003 | Bruce Stevens | BUILDING-RESIDENTIAL | REVIEW | Denied | PLAN CHECK COMMENTS - PROJECT #T03CM05223 1-Dec-03 1521 E MANLOVE ST. PLAN REVIEW FOR THE ABOVE REFERENCED STRUCTURE HAS BEEN COMPLETED. THIS LETTER REFLECTS COMMENTS TO BE ADDRESSED. IN ORDER TO FACILITATE A SHORTER BACK CHECK TIME, WE REQUEST THAT YOU PLEASE PROVIDE REVISED PLANS AND CALCULATIONS, HIGHLIGHTING ANY CHANGES, ALONG WITH A WRITTEN RESPONSE TO EACH OF THE NOTED ITEMS INDICATING ACTION TAKEN. FOUNDATION PLANS: 1. ALL SLABS AND PADS, INCLUDING LANDINGS AT ALL DOORS, SHALL BE SHOWN AND THEIR THICKNESS SPECIFIED. INDICATE THE SLOPE FOR EXTERIOR SLABS, PER R312. 2. DETAIL 3 AT INTERIOR DOES NOT FIT CONDITION FOR GARAGE / RESIDENCE TRANSITION. FLOOR PLANS: 1. WHERE DOES NOTE 5 ON FLOOR PLAN APPLY? STRUCTURAL PLANS: 1. ROOF FRAMING PLAN DOES NOT MATCH REAR ELEVATION OR WALL HEIGHT SHOWN ON SHEET 1 2. PROVIDE SIZE OF BEARING BEAMS AT REAR PORCH. 3. PLAN SHOWS CONFLICTING ROOF FRAMING CROSS SECTIONS. 4. PROVIDE DETAIL OF POST TO SLAB CONNECTION. 5. NOTE GLASS IN HAZARDOUS AREAS SHALL BE SAFETY GLASS PER R308.4. WINDOW AT FRONT IS LESS THAN 2 FT FROM THE FRONT DOOR, THEREFORE, IT MUST BE SAFETY GLAZED. PLUMBING PLANS: 1. PLUMBING VENTS SHALL BE A MINIMUM OF 10 FEET AWAY FROM ALL AIR INTAKES. 2. THE CITY OF TUCSON HAS ADOPTED THE 1994 UPC WITH THE STATE AMENDMENTS (ARIZONA STATE PLUMBING CODE). ALL PLANS MUST REFERENCE TO THIS CODE. MECHANICAL PLANS: 1. NOTE ON PLANS: MECHANICAL SHALL COMPLY WITH CHAPTERS 12 -16 AND18- 24 2000 IRC. 2. SHOW EXHAUST FAN LOCATIONS FOR BATHROOMS, WATER CLOSET COMPARTMENTS AND LAUNDRY ROOMS IN LIEU OF OPERABLE WINDOWS, PER R303.3 (IN MASTER BATH, WRONG ITEM IS LABLED "FAN") ELECTRICAL PLANS: 1. NOTE ON PLANS: ELECTRICAL WORK SHALL COMPLY WITH CHAPTERS 33 - 42, 2000 IRC. 2. SUBMIT PANEL SCHEDULE SHOWING CIRCUIT AMPACITY, WIRE SIZES, PANEL SIZE AND CIRCUIT NUMBERS. (RISER DIAGRAM SHOWS 100A PANEL WHILE PANEL SCHEDULE SHOWS 200A - PLEASE CORRECT TO MATCH) 3. SHOW LOCATIONS OF SMOKE DETECTORS PER R317. NOTE THAT ALL SMOKE DETECTORS MUST BE INTERCONNECTED WITH A POWER SOURCE FROM THE BUILDING WIRING, AND SHALL BE EQUIPPED WITH BATTERY BACKUP. SMOKE DETECTOR MUST BE PROVIDED IN HALLWAY LEADING TO BEDROOMS. IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT YOUR ASSIGNED PLANS EXAMINER: BRUCE STEVENS @ 791-5550 EXT. 1174 |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 12/08/2003 | TAMI ACHONG | OUT TO CUSTOMER | Completed |
| 12/03/2003 | ANGIE SHOFFSTALL | REJECT SHELF | Completed |