Permit Review Detail
Review Status: Completed
Review Details: SITE
Permit Number - T03CM05055
Review Name: SITE
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 10/29/2003 | JIM TATE | ENGINEERING | REVIEW | Denied | DATE: October 29, 2003 ACTIVITY NUMBER: T03CM05055 PROJECT NAME: Southern Arizona Vet Specialist PROJECT ADDRESS: 141 E Fort Lowell PROJECT REVIEWER: James C. Tate, P.E. The following items must be revised or added to the site plan. Please include a response letter with the next submittal that states how all comments have been addressed. Resubmittal Required: Site Plan Comments 1. Sidewalks must be physically separated from any vehicular travel lane by means of curbing, grade separation, barriers, railings or other means. Keynote 22 (?) states that the proposed sidewalk is at grade. Correct. DS 2-08.4.1 2. The new proposed sidewalk is directly in the path of the solid waste vehicle pickup area. Barriers need to be provided to prevent the dumpster from being pushed on to the sidewalk. 3. Place a note on the plan that all roof downspouts will be routed under any adjacent sidewalk. Sidewalks must be flood free for up to the ten year event. 4. Show roof drainage for the proposed addition. 5. A Flood Use Permit is required prior to Site Plan approval. 6. The Finish Floor Elevation shown on the Site Plan must be as high or higher than that specified on the approved Flood Use Permit and Elevation Certificate. If a datum conversion has been used the appropriate conversion calculation must be included on the plan. 7. An Elevation Certificate must be completed and returned to the Engineering Section prior to final inspection, occupancy of the structure, or issuance of Certificate of Occupancy. James C. Tate, P.E. Civil Engineer |
| 10/29/2003 | JIM TATE | SANITATION | REVIEW | Denied | See Engineering comments. |
| 11/21/2003 | Joseph Linville | LANDSCAPE | REVIEW | Approved | prev. dev. site |
| 11/24/2003 | PETER MCLAUGHLIN | HANDICAP-SITE | REVIEW | Approved | |
| 11/24/2003 | Peter McLaughlin | ZONING | REVIEW | Approv-Cond | SITE PLAN TRANSMITTAL TO: Kevin Petrick 11635 E. Tanque Verde Rd Tucson, AZ 85749 (520) 749-2340 FROM: Peter McLaughlin Senior Planner Development Services Dept. FOR: Patricia Gehlen Principal Planner Development Services Dept. PROJECT: T03CM05055 141 E. Ft. Lowell Rd Site Plan Review TRANSMITTAL: November 24, 2003 Upon completion of the following revision/addition, an over the counter review may be arranged to obtain stamped approval by the zoning review section without resubmitting the site plan. The following item must be revised on or added to the site plan: 1. The site plan keynotes do not line up correctly with their corresponding numbers on sheet C.1, making it difficult to read which number applies to the keynotes. Please revise. If you have any questions about this transmittal, please call Peter McLaughlin, (520) 791-5608. |
| 11/24/2003 | JOE LINVILLE | NPPO | REVIEW | Approved | Exception per prev. site plan. |
| 12/05/2003 | JIM EGAN | FIRE | REVIEW | Approved |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 12/09/2003 | TAMI ACHONG | OUT TO CUSTOMER | Completed |
| 12/05/2003 | ANGIE SHOFFSTALL | REJECT SHELF | Completed |