Permit Number: T03CM04917
Parcel: 123061120

Address:
2200 E ADAMS ST

Review Status: Completed

Review Details: 3RD PARTY REVIEW-RESIDENTIAL

Permit Number - T03CM04917
Review Name: 3RD PARTY REVIEW-RESIDENTIAL
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
12/19/2003 STANTEC 3RD PARTY REVIEW-COMMERCIAL REVIEW Denied SCOPE OF REVIEW:

The scope of this review covers Architectural, Structural, Plumbing, Mechanical, Model Energy and Electrical codes. All code references are to the 2000 International Residential Code (IRC) except for plumbing, which is to the 1994 Arizona Uniform Plumbing Code. All features were checked only to the extent allowed by the submittals provided. All portions of this project are assumed to meet or will meet other departmental requirements, conditions and concerns before permit approval.

GENERAL REQUIREMENTS:

q There are no general comments to be addressed.

ARCHITECTURAL:

q Detail and specify stair width (minimum 36"), rise and run (minimum 10" tread depth and 7-3/4" maximum riser height), landing width (a landing is required), and handrail heights (only required if 2 or more risers) [2000 IRC Sec. R312 through R316]. This previous comment has been partially addressed. The door swing change has eliminated the landing requirement, but the other items still need to be addressed.
STRUCTURAL:

q What size is the steel shown in the footing of Detail 4 on Sheet A3? Is the concrete stem wall reinforced? Grouted? Also, is it steel in the footing continuous? Please clarify. This previous comment is partially addressed. The steel in the footing has still not been noted. There is a new note regarding 2 bars of continuous steel but the leader goes to the stem wall and not the footing.

PLUMBING PLANS:

q There are no plumbing comments to be addressed.

MECHANICAL PLANS:

q There are no mechanical comments to be addressed.

ELECTRICAL PLANS:

q Receptacles shall be installed so that no point along a wall space in no more than 6 feet measured horizontally from an outlet in that space [2000 IBC Sec. R3801.2.1]. Any wall space that is 2 feet long or more requires at least one receptacle [2000 IRC Sec. R3801.2.2]. Specifically check both bedrooms and the wall behind the front door. This previous comment has been partially addressed. All the new receptacles need to be circuited.

q Hallways of 10 feet or more in length shall have at least one receptacle [2000 IBC Sec. E3801.10]. This previous comment has been partially addressed. All the new receptacles need to be circuited.

ENERGY:

q There are no energy comments to be addressed.

-End of Review-