Review Details: 3RD PARTY REVIEW-COMMERCIAL
Permit Number - T03CM04916
Review Name: 3RD PARTY REVIEW-COMMERCIAL
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 11/04/2003 | EROSE1 | WWM | REVIEW | Needs Review | |
| 11/04/2003 | GP | 3RD PARTY REVIEW-COMMERCIAL | REVIEW | Denied | ARCHITECTURAL COMMENTS Sheet 1 1. Please provide the item number of the dwelling unit separation wall from IBC Table 719.1(2) or the listing number from an approved testing agency. Ref. R321. Provide a detail of this wall. 2. Specify penetrations of the fire resistive wall to be fire resistance rated. Ref. R321.1. STRUCTURAL COMMENTS Sheet 2 1. Please specify the steel reinforcement for the post footing. PLUMBING COMMENTS Sheet 3 1. Please note 1994 UPC as amended by the City of Tucson as the governing plumbing code. Sheet 7 1. Revise section VII plumbing notes to reference the UPC. The City of Tucson local amendments eliminate Chapters 25 through 32 of the IRC and portions of Chapter 24. MECHANICAL COMMENTS Sheet 4 1. Please specify material, size and path for condensate disposal. Ref. M1411. ELECTRICAL COMMENTS Sheet 4 1. Distribute convenience receptacles so that no point along the wall is more than 6 feet from an outlet. Ref. E3801.2. 2. Provide a receptacle for the hallway which is greater than 10 feet in length. Ref. E3801.10. 3. Please show circuits 14 and 16 as spares in the panel schedule. ENERGY COMMENTS General 1. Please provide the SEER rating for the mechanical equipment. |
| 11/04/2003 | EROSE1 | WATER | REVIEW | Needs Review | |
| 11/04/2003 | EROSE1 | FIRE | REVIEW | Needs Review |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 11/04/2003 | ELAINE ROSE | OUT TO CUSTOMER | Completed |