Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Number: T03CM04912
Parcel: 127121470

Address:
5714 E 6TH ST

Review Status: Completed

Review Details: 3RD PARTY REVIEW-RESIDENTIAL

Permit Number - T03CM04912
Review Name: 3RD PARTY REVIEW-RESIDENTIAL
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
11/03/2003 EROSE1 WWM REVIEW Needs Review
11/03/2003 STANTEC 3RD PARTY REVIEW-COMMERCIAL REVIEW Denied SCOPE OF REVIEW:

The scope of this review covers Architectural, Structural, Plumbing, Mechanical, Model Energy and Electrical codes. All code references are to the 2000 International Residential Code (IRC) except for plumbing, which is to the 1994 Arizona Uniform Plumbing Code. All features were checked only to the extent allowed by the submittals provided. All portions of this project are assumed to meet or will meet other departmental requirements, conditions and concerns before permit approval.

GENERAL REQUIREMENTS:

q There are no general comments to be addressed.

ARCHITECTURAL:

q Note that bathtub and shower enclosures shall be finished [2000 IRC Sec. P2710] with ceramic tile [2000 IRC Sec. R702.4], or a listed enclosure, to a height of 72" above the drain [2000 IRC Sec. R307.2].

STRUCTURAL:

q Completely detail all connections and cross-reference to the foundation and framing plans:
· Rafter to top plate
· Beam to post
· Post to slab
· Sill to slab, anchor bolt sizes and spacing, post to sill plate
· Hanger types
· Straps

q Note and detail tie straps, framing anchors and joist hangers by type, size and required attachment to framing members.

q Wood sill plates shall be foundation grade redwood or pressure-treated wood [2000 IRC Sec. R324].

PLUMBING PLANS:

q Is the developmental length truly 125 feet? Adding up the dimension given on the plans the developmental length is 126 feet. Scaling the plans and assuming the 48 feet for the first leg from the meter is correct the dimension is 132 feet. The site plan on Sheet C-1 scales at 60 feet making the developmental length 144 feet. If the developmental length is over 125 feet then the main gas pipe between the gas dryer and the existing furnace needs to be increased from 1¼" to 1½ (based on a developmental length under 150 feet and a gas demand of 349 c.f.h.)[1994 AzUPC Chapter 12].

q Note and specify all piping materials (water, waste, and gas piping) [1994 AzUPC Sec. 1210, 604, and 715]. Water and waste piping are specified, but not the gas.

q Showers and tub-shower combinations shall be provided with individual control valves of the pressure balance type or of the thermostatic mixing valve type [1994 AzUPC Sec. 410.7].

MECHANICAL PLANS:

q Specify that the exhaust fan in the new restroom needs to be a minimum of 50 c.f.m. [2000 IRC Sec. R303.3 Exception].

ELECTRICAL PLANS:

q The main 200 amp panel is shown, but where is the 100 amp sub-panel? Please indicate.

q Any wall space that is 2 feet long or more requires at least one receptacle [2000 IRC Sec. R3801.2.2]. Two additional receptacles are required in the Arizona Room and one additional receptacle is required in the Guest Room based on this requirement.

q A receptacle outlet shall be provided adjacent to the basin in each bathroom [2000 IRC Sec. E3801.6]. Bathroom outlets shall be on a separate 20-amp circuit with no other outlets [2000 IRC Sec. E3603.4].

q Please indicate the electrical service on the plans for the evaporative cooler and the new air conditioner.

q Show locations of smoke detectors. Note that all smoke detectors must be interconnected with a power source from the building wiring, and shall be equipped with battery backup [2000 IRC Sec. R317]. One is require in the Guest Bedroom and one is required in the Arizona Room that serves as access.

ENERGY:

q Provide Energy Calculations per the 1998 International Energy Conservation Code (IECC), or comply with the 2000 IRC Chapter 11.

q Call out on the plans the "R" values of insulation, as well as the "U" values of the windows and doors in conformance with the energy calculations provided.

-End of Review-
11/03/2003 EROSE1 NPPO REVIEW Needs Review

Final Status

Task End Date Reviewer's Name Type of Review Description
11/03/2003 ELAINE ROSE OUT TO CUSTOMER Completed