Permit Review Detail
Review Status: Completed
Review Details: 3RD PARTY REVIEW-REVISION/OTHER
Permit Number - T03CM04891
Review Name: 3RD PARTY REVIEW-REVISION/OTHER
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 11/15/2003 | GP | 3RD PARTY REVIEW-COMMERCIAL | REVIEW | Denied | ARCHITECTURAL COMMENTS Sheet C.1 1. Please provide a dimension between the existing B occupancy office building and the proposed S-1 occupancy warehouse. 2. Clarify fire resistive construction provisions between the new and existing structures. Ref. IBC 602, IBC 302.3. STRUCTURAL COMMENTS General 1. Clarify if Metal Building is part of this permit. Structural Calculations for Metal Building are missing and the submitted plans from Steel Manufacturer contain note "Not for Approval". Please clarify and submit complete set of design and updated plans for the proposed Steel Building. 2. Engineer of Record, prepared Foundations Plan and Details shall include development and indicate on plans anchor bolt requirements at base of steel columns. Typical. Ref. IBC 1912 and complete structural information providing type and anchor bolt diameter and anchor bolt embedment. 3. Add to the list of Special Inspections, high strength bolts and field welding as noted at Steel Manufacturing Plans. |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 11/15/2003 | ELAINE ROSE | OUT TO CUSTOMER | Completed |