Permit Review Detail
Review Status: Completed
Review Details: RESUBMITTAL
Permit Number - T03CM04826
Review Name: RESUBMITTAL
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 04/12/2004 | PATRICIA GEHLEN | ZONING | REVIEW | Approved | |
| 04/13/2004 | ELIZABETH EBERBACH | ENGINEERING | REVIEW | Denied | SUBJECT: 2951 W. Salvia Drive REVIEWER: Doug Williams DATE: 13 April 2004 ACTIVITY NUMBERS: T03CM4826/T03BU02601 SUMMARY: Engineering Division has reviewed the grading plan received on March 15, 2004. Approval is not recommended at this time. Please ensure a resubmittal includes reference copies of the approved Tentative Plat and Stormwater Pollution Prevention Plan for this subdivision. Please address the following comments: SITE/GRADING PLAN COMMENTS 1. Please clarify the proposed limits of grading - the plan identifies two separate (eastern) grading limits. 2. Depict appropriate stormwater controls on the plan for this lot development, as discussed in the March 16, 2004 meeting. 3. Provide a basis of elevation with reference to City of Tucson (COT) Field Book and Page, in accordance with Development Standard (DS) 2-02.2.1.23; 4. Provide north-south and east-west cross sections, fully labeled and dimensioned. The cross sections must depict existing and proposed elevations with proposed slopes clearly indicated. 5. Depict overall lot drainage with flow arrows provided on the plan. Include proposed spot elevations and finished grades, any erosion protection, and any proposed walls with openings labeled and dimensioned, or with appropriate notes for opening locations/dimensions. 6. Provide easement dimensioning, and ensure all easements are depicted as indicated on the approved Tentative and/or Final Plats. The Final Plat may be accessed online at: http://tdotmaps.transview.org/mandr/mp/mplist.cfm?plan=MP-56-069 7. Please indicate the proper name of this subdivision in the title block (…Montage Vista II). Resubmittal shall include 2 copies of a revised grading plan, and reference sheets of the approved Tentative Plat and Stormwater Pollution Prevention Plan for Montage Vista II. If you have any questions, I can be reached at 791-5550, extension 1189 or Dwillia1@ci.tucson.az.us. Doug Williams Sr. Engineering Associate Engineering Division Development Services Departmen |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 04/13/2004 | SUE REEVES | OUT TO CUSTOMER | Completed |
| 04/13/2004 | ANGIE SHOFFSTALL | REJECT SHELF | Completed |