Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Number: T03CM04782
Parcel: 123070350

Review Status: Completed

Review Details: RESUBMITTAL

Permit Number - T03CM04782
Review Name: RESUBMITTAL
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
01/29/2004 Terry Stevens BUILDING-RESIDENTIAL REVIEW Denied PLAN CHECK COMMENTS - PROJECT #T03CM04782-R

01/30/04

PLAN REVIEW FOR THE ABOVE REFERENCED STRUCTURE HAS BEEN COMPLETED. THIS LETTER REFLECTS COMMENTS TO BE ADDRESSED. IN ORDER TO FACILITATE A SHORTER BACK CHECK TIME, WE REQUEST THAT YOU PLEASE PROVIDE REVISED PLANS AND CALCULATIONS, HIGHLIGHTING ANY CHANGES, ALONG WITH A WRITTEN RESPONSE TO EACH OF THE NOTED ITEMS INDICATING ACTION TAKEN.

GENERAL REQUIREMENTS:

1. ALL CORRECTIONS AND REVISIONS SHALL BE MADE ON THE ORIGINAL TRACINGS AND TWO NEW SETS OF PRINTS OR (1) SEPIA & (1) BLUE LINE SHALL BE RETURNED ALONG WITH ALL REDLINE PRINTS.

2. PEN OR PENCIL CORRECTIONS ON FINAL PRINTS WILL NOT BE ACCEPTABLE. TO AVOID DELAYS ENSURE ALL CORRECTIONS HAVE BEEN MADE, ARE COMPLETE AND HAVE BEEN COORDINATED ON ALL APPLICABLE DETAILS AND NOTES.

FLOOR PLANS:

1. LABEL ALL ROOMS AND SPACES, INCLUDING ROOMS ADJACENT TO NEW CONSTRUCTION.

2. PROVIDE DIMENSIONS ON PLANS.

3. PROVIDE ALL WINDOW AND DOOR SIZES AND TYPES, AND DESIGNATE THE OPERABLE PORTION OF WINDOWS, AS WELL AS THE LOCATIONS OF TEMPERED GLASS PER R308.4.

4. WALL AT KITCHEN IS BEING REMOVED, ARE CABINETS BEING REMOVED OR RELOCATED? WHAT IS HAPPENING TO EXISTING WASTE VENT AND ANY EXISTING ELECTRICAL WIRING.

5. FLOOR PLAN DOES NOT INDICATE KITCHEN WALL AS BEING REMOVED.

STRUCTURAL PLANS:

1. IT APPEARS THAT AN EXISTING PORCH IS REMAINING AND BEING REATTACHED. THE CALCS. FOR THE 31/8X191/2 GLULAM BEAM HAVE NOT TAKEN INTO ACCOUNT THE ADDITIONAL LOADS FROM THE PORCH.

2. PROVIDE CONNECTION DETAILS FOR PORCH TO ADDITION.

3. PROVIDE DETAIL OF BEARING LEDGER TO EXISTING MASONRY WALL

4. HOW ARE LEDGERS ATTACHED TO GLULAM BEAMS? DETAIL 2/A2

5. DETAIL 4/A2 ------HGLT HANGER REQUIRES A 4X LEDGER-----CALCS. ARE REQUIRING 8" OF BEARING FOR 51/8X101/2 GLULAM BEAM, HGLT5 HANGER HAS ONLY 6" OF BEARING.

6. DETAIL 4/A2---------1/2" ANCHOR BOLTS AT 48" OC ARE INADEQUATE FOR POINT LOAD FROM BEAM.

7. NOTE AND SPECIFY ALL ROOF SLOPES APPROPRIATE TO MATERIAL (SEE R905).

8. NOTE AND SIZE ALL ROOF DRAINS OR SCUPPERS ON FLAT-ROOFED AREAS PER R903.4.

SECTIONS - DETAILS - MISC. NOTES:

1. PROVIDE A BUILDING CROSS-SECTION. MORE THAN ONE MAY BE REQUIRED TO CLEARLY ILLUSTRATE HOW
THE STRUCTURE IS BUILT.------------MISSING FOR NEW WALL FROM BEAM TO SLAB.

2. WOOD SILL PLATES SHALL BE FOUNDATION GRADE REDWOOD OR PRESSURE-TREATED WOOD PER R324.

3. NOTE AND SPECIFY THE SIZE, SPACING AND LENGTH OF ANCHOR BOLTS FOR SILL PLATES, TOP PLATES AND
LEDGERS.




MECHANICAL PLANS:

1. THE NEW ROOM MUST BE PROVIDED WITH HEATING CAPABLE OF MAINTAINING A ROOM TEMPERATURE OF
68 DEGREES AT A POINT 3' ABOVE THE FLOOR PER R303.6---------INDICATE EXISTING SOURCE, IF APPLYS.

ELECTRICAL PLANS:

1. PLANS INDICATE ELEC. ON WALL THAT IS BEING REMOVED? CLARIFY.

IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT YOUR ASSIGNED PLANS EXAMINER:
TERRY STEVENS @ 791-5550 EXT. 1112

Final Status

Task End Date Reviewer's Name Type of Review Description
02/02/2004 TAMI ACHONG OUT TO CUSTOMER Completed
01/30/2004 ANGIE SHOFFSTALL REJECT SHELF Completed