Review Status: Completed
Review Details: RESIDENTIAL BLDG/ZONING/ENGINE/WWM
Permit Number - T03CM04777
Review Name: RESIDENTIAL BLDG/ZONING/ENGINE/WWM
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 10/20/2003 | GERRY KOZIOL | WWM | REVIEW | Denied | Spoke to Matthew. Perc and design will be brought in as soon as possible - 10/20/03 |
| 11/04/2003 | Terry Stevens | BUILDING-RESIDENTIAL | REVIEW | Denied | PLAN CHECK COMMENTS - PROJECT #T03CM04777 11/7/03 PLAN REVIEW FOR THE ABOVE REFERENCED STRUCTURE HAS BEEN COMPLETED. THIS LETTER REFLECTS COMMENTS TO BE ADDRESSED. IN ORDER TO FACILITATE A SHORTER BACK CHECK TIME, WE REQUEST THAT YOU PLEASE PROVIDE REVISED PLANS AND CALCULATIONS, HIGHLIGHTING ANY CHANGES, ALONG WITH A WRITTEN RESPONSE TO EACH OF THE NOTED ITEMS INDICATING ACTION TAKEN. GENERAL REQUIREMENTS: 1. ALL CORRECTIONS AND REVISIONS SHALL BE MADE ON THE ORIGINAL TRACINGS AND TWO NEW SETS OF PRINTS OR (1) SEPIA & (1) BLUE LINE SHALL BE RETURNED ALONG WITH ALL REDLINE PRINTS. 2. PEN OR PENCIL CORRECTIONS ON FINAL PRINTS WILL NOT BE ACCEPTABLE. TO AVOID DELAYS ENSURE ALL CORRECTIONS HAVE BEEN MADE, ARE COMPLETE AND HAVE BEEN COORDINATED ON ALL APPLICABLE DETAILS AND NOTES. 3. ALL ENGINEERS AND ARCHITECTS INVOLVED IN THE DESIGN OF THE STRUCTURE ARE TO SEAL THE RELATED SHEETS OF PLANS, DETAILS AND CALCULATIONS. THIS IS IN ACCORDANCE WITH THE RULES OF THE STATE BOARD OF TECHNICAL REGISTRATION. FLOOR PLANS: 1. PROVIDE THE LOCATIONS OF TEMPERED GLASS PER R308.4. REQUIRED AT WINDOW "A" AT FOYER AND STAIR LANDING 2. PROVIDE ACCESS TO EACH SEPARATE ATTIC AND CRAWL SPACE THAT EXCEEDS 30SF. DESIGNATE LOCATIONS ON THE DRAWINGS. OPENINGS SHALL NOT BE LESS THAN 22" BY 30". THE ATTIC ACCESS SHALL PROVIDE A MINIMUM OF 30" OF HEADROOM, AND SHALL BE LOCATED IN A HALLWAY OR READILY ACCESSIBLE SPACE PER R807. 3. COMPLY WITH R309.2. PROVIDE ½" GYPSUM BOARD ON ALL WALLS COMMON TO THE GARAGE AND HOUSE. WHERE SEPARATION IS A FLOOR-CEILING ASSEMBLY, THE STRUCTURE SUPPORTING THE SEPARATION SHALL ALSO BE PROTECTED BY A MINIMUM ½" GYPSUM BOARD OR EQUIVALENT. STRUCTURAL PLANS: 1. STRUCTURAL PLANS PAGES 10, 11, AND 12 HAVE DUPLICATE PAGES. ONE SET HAS ENGINEERS STAMPS AND ONE SET DOES NOT. REMOVE THE COUNTY APPROVED SET AND SUBMITT ENGINEERED APPROVED [STAMPED] PAGES. ELEVATIONS: 1. NOTE AND DIMENSION THAT THE FIREPLACE CHIMNEY MUST TERMINATE A MINIMUM OF 2' ABOVE ANY POINT OF ROOF WITHIN 10' MEASURED HORIZONTALLY AND NOT LESS THAN 3' ABOVE THE POINT WHERE THE CHIMNEY PASSES THROUGH THE ROOF, PER R1001.6 PLUMBING PLANS: 1. WATER LINE: PROVIDE TOTAL FIXTURE DEMAND & MAXIMUM DEVELOPED LENGTH CALCS. APPEAR TO BE INCORRECT, 570' ? NO. OF UNITS? NO WATER PRESSURE INDICATED--------SEE ATTACHED-------CLEARLY INIDCATE SIZE OF REQUIRED WATER METER 2. NOTE ON PLAN COMPLIANCE WITH WATER CONSERVATION; WATER CLOSETS 1.6 GALLONS PER FLUSH, SINKS AND SHOWERHEADS 3 GALLONS PER MINUTE. 3. NOTE ON PLANS THAT SHOWER AND TUB / SHOWER COMBINATIONS THAT HAVE INDIVIDUAL CONTROL VALVES SHALL BE OF THE PRESSURE BALANCE OR THERMOSTATIC MIXING VALVE TYPE. MECHANICAL PLANS: 1. GAS APPLIANCES SHALL COMPLY WITH 1994 UPC WITH STATE AMENDMENTS FOR COMBUSTION AIR REQUIREMENTS. DETAIL HOW. NOTE: THE CITY HAS NOT ADOPTED CHAPTER 17 OF THE IRC 2000 ELECTRICAL PLANS: 1. NOTE THE LOCATIONS OF THE SUBPANELS. INIDCATE SIZE OF FEEDER WIRES. IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT YOUR ASSIGNED PLANS EXAMINER: TERRY STEVENS @ 791-5550 EXT. 1112 Residential Fixture Unit Calculations Water Hot Water Waste Description Quantity Fixture Units Extension Fixture Units Extension Fixture Units Extension Bidet Clotheswasher 1 6 6 4.5 4.5 2 2 Floor Drain Floor Sink Hose Bibb 6 3 18 Lavatory 4 1 4 0.75 3.0 1 4 Ice Maker (3/8") Shower/Bathtub 4 2 8 1.5 6.0 2 8 Sink (Bar) 1 1 1 0.75 0.8 1 1 Sink (Kitchen) 1 2 2 1.5 1.5 2 2 Sink (Laundry) 1 2 2 1.5 1.5 2 2 Water Closet (Tank) 3 3 9 4 12 Water Supply 3/8" Water Supply 1/2" Water Supply 3/4" Water Supply 1" Totals 21 Fixtures 50 F.U. 17.3 F.U. 31 F.U. Total Demand 29 GPM 12 GPM Water Pipe Sizing - Section 610.4, UPC 1994 Length 400 Design Pressure 60 PSI Meter Size Pipe Size Fixture Units Meter 4 3/4 1/2 0 Minimum Pressure 15 PSI 3/4 3/4 4 Lift (Feet) 40 0.43 17 PSI 3/4 1 10 1 1 12 Design Pressure Range 30-45 PSI 3/4 1 1/4 17 Developed Length 350 FT 1 1 1/4 19 6.9 PSI/100 FT 1 1/2 1 1/4 21 Max. Fixture Units 1 1 1/2 32 Pipe Size Area (Sq In.) Waste Vent 1 1/2 1 1/2 36 1 1/2 2.0 1 8* 2 1 1/2 38 2 3.4 8* 24 1 2 66 2 1/2 4.8 14* 48 1 1/2 2 104 3 7.4 35** 84 2 2 124 4 12.7 216*** 256 2 2 1/2 240 * Except 6-unit traps or water closets ** Not to exceed 3 W.C. or 6-unit traps *** 173 fixture units at 1/8" slope |
| 11/14/2003 | PATRICIA GEHLEN | ZONING | REVIEW | Denied | see comments on card. |
| 12/04/2003 | RSCHULE1 | ENGINEERING | REVIEW | Needs Review | |
| 12/04/2003 | RSCHULE1 | NPPO | REVIEW | Needs Review |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 12/08/2003 | LISA LESNY | OUT TO CUSTOMER | Completed |
| 12/04/2003 | LISA LESNY | REJECT SHELF | Completed |