Permit Review Detail
Review Status: Completed
Review Details: RESIDENTIAL BLDG/WWM
Permit Number - T03CM04728
Review Name: RESIDENTIAL BLDG/WWM
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 02/27/2004 | David Witt | BUILDING-RESIDENTIAL | REVIEW | Denied | PLAN CHECK COMMENTS - PROJECT #T03CM04728 3/1/04 2241 E. 7th St. PLAN REVIEW FOR THE ABOVE REFERENCED STRUCTURE HAS BEEN COMPLETED. THIS LETTER REFLECTS COMMENTS TO BE ADDRESSED. IN ORDER TO FACILITATE A SHORTER BACK CHECK TIME, WE REQUEST THAT YOU PLEASE PROVIDE REVISED PLANS AND CALCULATIONS, HIGHLIGHTING ANY CHANGES, ALONG WITH A WRITTEN RESPONSE TO EACH OF THE NOTED ITEMS INDICATING ACTION TAKEN. SCOPE OF REVIEW: THE SCOPE OF THIS PLAN REVIEW COVERS ARCHITECTURAL, PLUMBING, MECHANICAL, MODEL ENERGY AND ELECTRICAL CODES. ALL CODE REFERENCES ARE TO THE 2000 IRC AND STATE PLUMBING CODE. ALL FEATURES WERE CHECKED ONLY TO THE EXTENT ALLOWED BY THE SUBMITTALS PROVIDED. ALL PORTIONS OF THIS PROJECT ARE ASSUMED TO MEET OR WILL MEET OTHER DEPARTMENTAL REQUIREMENTS, CONDITIONS AND CONCERNS BEFORE PERMIT APPROVAL. GENERAL REQUIREMENTS: 1. ALL PLANS SHALL BE LEGIBLE AND A SCALE NO SMALLER THAN ¼ INCH = 1-FOOT SHALL BE USED FOR ALL FLOOR PLANS, FRAMING PLANS AND ELEVATIONS. DETAILS &CROSS SECTIONS AT A MINIMUM 3/8 INCH = 1-FOOT SCALE. 2. ALL CORRECTIONS AND REVISIONS SHALL BE MADE ON THE ORIGINAL TRACINGS AND TWO NEW SETS OF PRINTS OR (1) SEPIA & (1) BLUE LINE SHALL BE RETURNED ALONG WITH ALL REDLINE PRINTS. 3. PEN OR PENCIL CORRECTIONS ON FINAL PRINTS WILL NOT BE ACCEPTABLE. TO AVOID DELAYS ENSURE ALL CORRECTIONS HAVE BEEN MADE, ARE COMPLETE AND HAVE BEEN COORDINATED ON ALL APPLICABLE DETAILS AND NOTES. SITE PLAN: 1. INDICATE THE LOCATION OF THE SEWER OR SEPTIC LINE ON THE PROPERTY, AND WHERE IT ENTERS THE BUILDING. FOUNDATION: 1. DIMENSION THE LOCATIONS OF THE PORCH AND BALCONY STAIR FOOTINGS. FLOOR PLANS: 1. PLEASE DESCRIBE THE GLASS IN THE DINING ROOM / PORCH DOOR'S SIDELITE. 2. PROVIDE HANDRAILS FOR STAIRS, I/S AND O/S. 3. PROVIDE A 1-HOUR FIRE WALL AT THE CARPORT THAT IS LESS THAN 3-FT. FROM THE PROPERTY LINE. 4. DIMENSION THE LOCATIONS OF THE INTERIOR PARTITIONS. 5. THE WALLS AND SOFFITS OF THE ENCLOSED SPACE UNDER STAIRS SHALL BE PROTECTED ON THE ENCLOSED SIDE WITH ½" GYPSUM BOARD PER R314.8. IS THERE AN ENCLOSED SPACE UNDER THE INSIDE STAIRS? 6. HOW DO THE OPEN TREADS OF THE BALCONY STAIRS, SD-19 / 4, COMPLY WITH R314.2.1 ? 7. SHOW THAT EACH WATER CLOSET IS LOCATED IN A CLEAR SPACE NOT LESS THAN 30" WIDE AND HAS A CLEAR SPACE IN FRONT OF NOT LESS THAN 24" PER R307.2 (FIGURE). 8. PLEASE PROVIDE A NON-ABSORBENT WALL 72" MINIMUM ABOVE THE FLOOR PER R307.2 . 9. THE WATER HEATER IS REQUIRED TO BE ACCESSIBLE WITHOUT REMOVING THE REFRIGERATOR. STRUCTURAL PLANS: 1. SPECIFY DESIGN CRITERIA ON PLANS. VALUES FOR FLOOR DEAD LOAD AND LIVE LOAD, ROOF DEAD LOAD AND LIVE LOAD. 2. PROVIDE STAIRWAY CONNECTION DETAILS. ELEVATIONS: 1. NOTE AND SIZE ALL ROOF DRAINS OR SCUPPERS ON FLAT-ROOFED AREAS PER R903.4. 2. SHOW CALCULATION OF ATTIC VENTILATION AREA IN COMPLIANCE WITH R806.2. NOTE LOCATION OF ALL VENTS NEEDED TO COMPLY. SECTIONS - DETAILS - MISC. NOTES: 1. PROVIDE A CROSS-SECTION OF THE INTERIOR STAIRS. 2. PROVIDE A CROSS-SECTION OF THE PLANTER (?) ON THE SECOND FLOOR. 3. PROVIDE A CROSS-SECTION OF AN INTERIOR WALL. 4. HOW DOES THE DRYWALL ON THE CEILING COMPLY WITH TABLE R702.3.5 FOOTNOTE D ? 5. SD-19 ; PLEASE SPECIFY THE SCREWS FOR THE L-70 AND L-50 CONNECTIONS TO STEEL AND TO CONCRETE. 6. I COULDN'T FIND A LISTING FOR "HTT-14" IN SIMPSON. PLEASE HELP. 7. SD-17 / 4 ; PROVIDE A JOIST / BEAM CONNECTION. 8. SD-17 / 4 ; DESCRIBE THE LEDGER AND THE LEDGER BOLTS. 9. S-3 / 2 ; CLARIFY THE "C-1" AT THE LEFT END, MASONRY WALL, OF THE "B-1" AT THE STAIRS. PLUMBING PLANS: 1. NOTE AND SPECIFY ALL PIPING MATERIALS. 2. PROVIDE AN ISOMETRIC DRAWING OF WASTE LINES. SHOW SIZES OF WASTE LINES, VENTS AND REQUIRED CLEANOUTS. 3. JUSTIFY THE EXISTING GAS AND WATER SYSTEMS ABILITY TO HANDLE THE NEW LOADS. MECHANICAL PLANS: 1. NOTE ON PLANS: MECHANICAL SHALL COMPLY WITH CHAPTERS 12 - 24 2000 IRC. 2. PROVIDE A RETURN AIR SIZED IN ACCORD WITH R M1602 . 3. SHOW EXHAUST FAN LOCATIONS FOR THE LAUNDRY ROOM AND BATHROOM IN LIEU OF OPERABLE WINDOWS, PER R303.3 ELECTRICAL PLANS: 1. PROVIDE A SMOKE DETECTOR AT THE TOP OF THE STAIRS AND FOR THE BEDROOM. PROVIDE A NOTE THAT THE EXISTING SLEEPING AREAS ARE TO BE PROVIDED WITH SMOKE DETECTORS PER R317.1.1 . 2. WHERE CEILING FANS ARE SHOWN ON THE PLANS, PROVIDE A NOTE INDICATING ONLY APPROVED OUTLET BOXES SHALL BE USED, PER E4001.6. IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT YOUR ASSIGNED PLANS EXAMINER: DAVE WITT @ 791-5550 EXT. 1110 |
| 03/09/2004 | GERRY KOZIOL | WWM | REVIEW | Approved |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 03/10/2004 | EGRANT1 | OUT TO CUSTOMER | Completed |