02/26/2004 Patricia Gilbert ENGINEERING REVIEW Denied DATE: February 26, 2004
ACTIVITY NUMBER: T03CM04567
PROJECT NAME: Ezrre Gardener Apartments
PROJECT ADDRESS: 3022 North Gernimo Apartments
PROJECT REVIEWER: Patricia Gilbert

The following items must be revised or added to the site plan. Please include a response letter with the next submittal that states how all comments have been addressed.

RESUBMITTAL REQUIRED: SITE PLAN

1. Each service area is required to have a clear approach of fourteen (14) feet by forty (40) feet for the collection vehicle. The maximum back-up distance for the collection vehicle shall be forty (40) feet. The solid waste vehicle can not back up safely. For the current location to be approvable a Development Standard Modification Request (DSMR) process needs to take place. Contact Marilyn Kalthoff at 791-5550 ext. 1117 for assistance with the DSMR process.

2. A minimum setback distance of five (5) feet for a pedestrian refuge area must be maintained between any enclosed structure and a PAAL. Revise the plan to show 4' sidewalks and a 5' pedestrian refuge area when a structure is adjacent to a PAAL. It is not clear if there is a 5' setback on both sides of the backup area for the solid waste vehicle. It is unclear what is attached to both proposed structures that obstructs 5' of clear space. Please clarify, label or remove the lines. DS 3-05.2.2.B.1.
03/01/2004 JIM EGAN FIRE REVIEW Approv-Cond Rsesidential fire sprinklers required for Apartment Units #5 and #6.
03/17/2004 Andrew Connor LANDSCAPE REVIEW Denied 1) Refuse enclosure wall is required to be 6' per LUC Table 3.7.2-I revise keynote #3 and indicate on site and landscape plans

2) The parking lot / vehicular use area is required to be screened with a 5' masonry wall from all residential zoned properties per LUC Table 3.7.2-I. Revise landscape and site plans.

3) Provide a 5'screen for the vehicular use area along Geronimo Ave per LUC Table 3.7.2-I.

4) Screens may be located in the landscape border if the criteria indicated in LUC3.7.3.2 are met.

5) Any screen higher than thirty (30) inches must be located outside of the sight visibility triangle per LUC 3.7.3.4

6) Provide curbing or alternative protection for landscaping within or adjacent to vehicle use area per LUC 3.7.2.3.B

7) Identify tree in Keynote #14 per LUC 3.8.4.2

8) Interior landscape borders are required along all property lines excluding Multi-use residences per LUC 3.7.2-I

9) One (1) canopy tree must be provided for every thirty-three (33) linear feet of the interior landscape border per LUC 3.7.2.4


10) All disturbed areas shall be treated with ground cover such as Decomposed Granite, indicate on landscape plan per LUC 3.7.2.7

11) Landscape plan shall include irrigation specification design and layout per DS 2-07.5.4.A & DS 2-07.5.4.B included sleeves for driveways and sidewalks, locations of valves, low-flow bubblers or drip irrigation.

12) Indicate methods by which water harvesting or storm water runoff is used to benefit all planting areas on the site per DS 2-07.2.2.B.6

13) Submit NPPO plan or Application for Exception including pictures of vegetation on site per DS 2-15.2.0
03/17/2004 Andrew Connor NPPO REVIEW Denied Submit NPPO plan or Application for Exception including pictures of vegetation on site per DS 2-15.2.0
03/22/2004 Peter McLaughlin ZONING REVIEW Denied SITE PLAN TRANSMITTAL

TO: Ruben Ezzre
1120 W. Glenn
Tucson, AZ 85705

FROM: Peter McLaughlin
Senior Planner

FOR: Patricia Gehlen
Principal Planner

PROJECT:
T03CM04567
Ezzre Gardner Apartments
3022 N. Geronimo Ave

TRANSMITTAL: March 23, 2004

COMMENTS: Upon completion of the following revision/addition, an over the counter review may be arranged to obtain stamped approval by the zoning review section without resubmitting the site plan. The following item must be revised on or added to the site plan:

1. The Assessor record indicates the site is made up of a portion of a lot. Please provide a copy of the approved lot split documentation of the property to the zoning review section.
DS 2-02.2.1.A.2

2. If easements exist on the site, please show their location, type, width and provide recordation information.
DS 2-02.2.1.A.10

3. If free-standing outdoor lighting is proposed for this site, please detail on the site plan.
DS 2-02.2.1.A.25

4. A minimum setback of 5 feet for pedestrian refuge, including the 4-foot sidewalk, must be maintained between the building and the PAAL/turnaround. DS 3-05.2.2.B.1

5. Revisions may not be made using white out. On the final plan sets make all changes without erasures or white out.

6. The location, type, size and height of any proposed free-standing signage must be shown.
DS 2-02.2.1.A.13

If you have any questions about this transmittal, please call Peter McLaughlin, (520) 791-5608.

Final Status

Task End Date Reviewer's Name Type of Review Description
03/25/2004 TAMI ACHONG OUT TO CUSTOMER Completed
03/23/2004 TAMI ACHONG REJECT SHELF Completed