Permit Review Detail
Review Status: Completed
Review Details: SITE
Permit Number - T03CM04567
Review Name: SITE
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 10/31/2003 | Patricia Gilbert | ENGINEERING | REVIEW | Denied | DATE: November 5, 2003 ACTIVITY NUMBER: T03CM04567 PROJECT NAME: Ezrre Gardener Apartments PROJECT ADDRESS: 3022 North Gernimo Apartments PROJECT REVIEWER: Patricia Gilbert The following items must be revised or added to the site plan. Please include a response letter with the next submittal that states how all comments have been addressed. RESUBMITTAL REQUIRED: SITE PLAN 1. Each service area is required to have a clear approach of fourteen (14) feet by forty (40) feet for the collection vehicle. The maximum back-up distance for the collection vehicle shall be forty (40) feet. The solid waste vehicle can not back up safely. Contact John Clark from Environmental Services for direction and approval on the solid waste location, 791-5414 ext. 1004. 2. Retention and/or detention is not required on this site. Rename the retention basin to "Water Harvesting Area." 3. Sidewalks shall be flood free for all storm discharges of up to a ten (10) year flood event. Place a note on the plan, "All roof down spouts on all new structures must be routed under any adjacent sidewalks." Revise plan as necessary. DS 2-08.4.1.E. 4. Sidewalks are required as part of new development of all properties. All new applications for building permits shall provide four (5) foot wide sidewalks along the entire length of street frontage, whether public or private, of the property in question. Currently the proposed location of the new sidewalk is 4' and in the driveway. Revise the plan to show 5' sidewalks and place the sidewalk out of the driveway. DS 3-01.3.3.A. 5. A minimum setback distance of five (5) feet for a pedestrian refuge area must be maintained between any enclosed structure and a PAAL. Revise the plan to show 5' sidewalks when a structure is adjacent to a PAAL. DS 3-05.2.2.B.1. |
| 11/24/2003 | Joseph Linville | LANDSCAPE | REVIEW | Denied | 1) Include the legal decription of the property on the Landscape Plan/NPP Plan. DS 2-07.2.1.B Lot dimensions on the landscape plan differ from those indicate on the site plan. 2) Per DS 2-15.3.1.A.3 an aerial photo is required. Refer to the standard for plan requirements. 3) Clarify dust control treatments proposed for the adjacent right of way area. LUC 3.7.2.4.A.3 In areas where no sidewalk is required/provided a minimum 4' wide clear pedestrian path is to be maintained. 1/4 DG may be used if compacted to the City Engineer's standards. |
| 11/25/2003 | Peter McLaughlin | ZONING | REVIEW | Denied | SITE PLAN TRANSMITTAL TO: Ruben Ezzre 1120 W. Glenn Tucson, AZ 85705 FROM: Peter McLaughlin Senior Planner FOR: Patricia Gehlen Principal Planner PROJECT: T03CM04567 Ezzre Gardner Apartments 3022 N. Geronimo Ave TRANSMITTAL: November 26, 2003 COMMENTS: Upon completion of the following revision/addition, an over the counter review may be arranged to obtain stamped approval by the zoning review section without resubmitting the site plan. The following item must be revised on or added to the site plan: 1. The Assessor record indicates the site is made up of a portion of a lot. Please provide a copy of the approved lot split documentation of the property to the zoning review section. DS 2-02.2.1.A.2 2. If easements exist on the site, please show their location, type, width and provide recordation information. DS 2-02.2.1.A.10 3. If free-standing outdoor lighting is proposed for this site, please detail on the site plan. DS 2-02.2.1.A.25 4. The location, type, size and height of any proposed free-standing signage must be shown. DS 2-02.2.1.A.13 5. The title of the landscape plan reads RWG Apartments and has a different zip code. Please revise title to be consistent to be consistent with the site plan. LUC 2.3.5 If you have any questions about this transmittal, please call Peter McLaughlin, (520) 791-5608. |
| 11/26/2003 | PETER MCLAUGHLIN | HANDICAP-SITE | REVIEW | Approved | |
| 11/28/2003 | JOE LINVILLE | NPPO | REVIEW | Denied | 1) Include the legal decription of the property on the Landscape Plan/NPP Plan. DS 2-07.2.1.B Lot dimensions on the landscape plan differ from those indicate on the site plan. 2) Per DS 2-15.3.1.A.3 an aerial photo is required. Refer to the standard for plan requirements. 3) Clarify dust control treatments proposed for the adjacent right of way area. LUC 3.7.2.4.A.3 In areas where no sidewalk is required/provided a minimum 4' wide clear pedestrian path is to be maintained. 1/4 DG may be used if compacted to the City Engineer's standards. |
| 12/01/2003 | JIM EGAN | FIRE | REVIEW | Denied | Fire apparatus access roadway must be provided and extended to within 150 feet of all portions of exterior walls of all structures. |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 12/04/2003 | LISA LESNY | OUT TO CUSTOMER | Completed |
| 12/03/2003 | ANGIE SHOFFSTALL | REJECT SHELF | Completed |