Permit Review Detail
Review Status: Completed
Review Details: 3RD PARTY REVIEW-REVISION/OTHER
Permit Number - T03CM04430
Review Name: 3RD PARTY REVIEW-REVISION/OTHER
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 10/24/2003 | GP | 3RD PARTY REVIEW-COMMERCIAL | REVIEW | Denied | ARCHITECTURAL COMMENTS Sheet A-2 1. Provide minimum fixture clearance in typical detail 1/A-2. Ref. ANSI A117.1, 604.3.1. Comment restated. Sheet A-3 1. Provide a valuation report number for the sand finish stucco system referenced in keynote number 4. Comment restated. Response indicated was simply the word "RESPONSE:". STRUCTURAL COMMENTS GSN 1. Add to the list of Special Inspections earthwork, grading and filling and epoxy bolts as used. Sheet S1 1. Provide masonry pier design due to out-of-plane wind loads by accounting for the adjacent openings plus combined with axial compression for the 12" thick piers at South wall. Ref. ACI 530-99/ASCE 5-99/ TMS 402-99 Section 2.3.3. Please see masonry piers P1 and undefined piers at front canopy with footing mark "F4". Provide cross section and reinforcement detailing of masonry piers at front canopy, not found addressed on plans. PLUMBING COMMENTS Sheet P-1 1. Show the hose bibbs referenced in the fixture schedule on the plan and provide cross connection control. Ref. UPC 603. Comment restated. MECHANICAL COMMENTS Sheet M-1 1. Provide outside ventilation air calculations. Ref. INC 403. The air conditioned space appears to be ready to lease. Comment restated. ELECTRICAL COMMENTS Sheet E-1 1. Provide fixture cut sheets for exterior lighting to determine compliance with outdoor lighting code requirements. Comment restated. ENERGY COMMENTS General 1. Include building envelope criteria for energy code compliance. Ref. IECC 701. Comment restated. |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 10/24/2003 | ELAINE ROSE | OUT TO CUSTOMER | Completed |