Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Permit Review Detail
Review Status: Completed
Review Details: SITE
Permit Number - T03CM04419
Review Name: SITE
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 09/12/2003 | JIM EGAN | FIRE | REVIEW | Approved | |
| 09/29/2003 | DOUG WILLIAMS | ENGINEERING | REVIEW | Denied | SUBJECT: Tucson Federal Credit Union REVIEWER: Doug Williams DATE: 30 September 2003 ACTIVITY NUMBER: T03CM04419 T14S, R13E, Sec.27 SUMMARY: Engineering Division has reviewed the site plan received September 29, 2003. Approval is not recommended at this time. The following comments are offered: SITE PLAN COMMENTS: 1. Depict the Major Streets and Routes (MS&R) sight visibility triangles on sheet "RS" (Development Standard - DS 2-02.2.1.10 and 3-01.5.1 B 2 - see penciled depictions on plan); 2. Provide a basis of elevation based on City of Tucson datum, with City field book and page number (DS 2-02.2.1.23); 3. Please revise the screen wall details and keynote # 6, or provide a note to ensure wall heights will not exceed 30" within the MS&R sight visibility triangles, in accordance with DS 3-01.5.0; 4. Depict and label minimum 18' curb return radii at all locations (keynotes 11 and 12) where parking area access lanes (paal's) intersect another paal, where the solid waste, fire and loading vehicles must maneuver (DS 2-02.2.1.32, 6-01.0, 3-01.10, Figure 6 and 3-05.2.1 C 3 a); 5. Depict roof drainage directions on sheet "RS" and provide scuppers for conveyance of 10-year flows under sidewalk areas where the additions are proposed, as applicable, per DS 2-08.4.1 and 5.1 E. Please revise any pertinent details on referenced sheets - 1/A4.1, for example; 6. Revise the proposed new sidewalk connecting the site to Mission Road (keynote # 54) to conform to a maximum of 3 longitudinal to 1 lateral (3:1) transition (DS 3-01.3.3 B 1 d); If you have any questions, I can be reached at 791-5550, extension 1189 or Dwillia1@ci.tucson.az.us. Doug Williams Sr. Engineering Associate Engineering Division Development Services Department |
| 09/30/2003 | DOUG WILLIAMS | SANITATION | REVIEW | Denied | The proposed new curbing (keynote # 32) south of the structure appears to prohibit an unobstructed 14' by 40' clear approach for the solid waste vehicles servicing the existing dumpster to the south. The site plan must demonstrate and depict vehicle maneuverability in accordance with DS 6-01.4.1C and 6-01.10 Figure 1 (Turning Radii For Service Vehicles). |
| 10/07/2003 | Joseph Linville | LANDSCAPE | REVIEW | Denied | Submit the approved development plans and landscape/NPPO plans with the site review application after CDRC approval. |
| 10/13/2003 | David Rivera | HANDICAP-SITE | REVIEW | Denied | see zoning comments. |
| 10/13/2003 | David Rivera | ZONING | REVIEW | Denied | This plan will not be reviewed by the Zoning Review Section for zoning or for handicap compliance. A revised Development Plan is under review and waiting for approval stamps and signatures. The approved revised development plan must be submitted with the building plans and approved as a site plan. Before submittal of any subsequent plans please ensure that the approved development plan has been inserted with the building plans. |
| 10/13/2003 | JOE LINVILLE | NPPO | REVIEW | Denied | Submit the approved development plans and landscape/NPPO plans with the site review application after CDRC approval. |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 10/16/2003 | LISA LESNY | OUT TO CUSTOMER | Completed |
| 10/14/2003 | ANGIE SHOFFSTALL | REJECT SHELF | Completed |