Permit Review Detail
Review Status: Completed
Review Details: COMMERCIAL TI
Permit Number - T03CM04419
Review Name: COMMERCIAL TI
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 09/12/2003 | JIM EGAN | FIRE | REVIEW | Approved | |
| 09/18/2003 | Robert Sherry | PLUMBING-COMMERCIAL | REVIEW | Denied | 1. Confirm that the existing vitrified clay pipe is listed for use under the building and that the proper separation is maintained between the VCP and the underground water piping. Reference Sections 313.4, 609.2, and 701.1, UPC 1994. 2. Provide calculations showing the water supply piping is sized in accordance with Section 610.4, UPC 1994. Include all existing fixtures when calculating the total demand and determining pipe sizes. 3. Revise the size of the wall cleanout at P2R/P2L to conform with Section 707.11, UPC 1994. 4. Revise specification item 16 to comply with Section 609.3.2, UPC 1994. Joints in underground copper piping are to be brazed not soldered. |
| 09/18/2003 | ROBERT SHERRY | WATER | REVIEW | Approved | |
| 09/18/2003 | ROBERT SHERRY | MECHANICAL-COMMERCIAL | REVIEW | Approved | |
| 09/26/2003 | RAUL PALMA | BUILDING-COMMERCIAL | REVIEW | Approved | |
| 09/30/2003 | DOUG WILLIAMS | ENGINEERING | REVIEW | Denied | Refer to comments under "site" review comments - building plans may not be approved prior to site plan approval. |
| 10/02/2003 | GERRY KOZIOL | WWM | REVIEW | Approved | |
| 10/02/2003 | LINDA BUCZYNSKI | ELECTRICAL-COMMERCIAL | REVIEW | Approved | |
| 10/14/2003 | DAVID RIVERA | ZONING | REVIEW | Denied | Building plans cannot be approved until a copy of the approved development is provided with the building plans and has been stamaped for site plan approval. |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 10/16/2003 | LISA LESNY | OUT TO CUSTOMER | Completed |