Permit Review Detail
Review Status: Completed
Review Details: RESIDENTIAL BLDG/WWM
Permit Number - T03CM04416
Review Name: RESIDENTIAL BLDG/WWM
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 10/16/2003 | GERRY KOZIOL | WWM | REVIEW | Denied | Needs 8th Floor credit evaluation Needs to review location of connection to public sewer (fronts 15" line) Are you connecting to an existing HCS? |
| 10/31/2003 | DAVE WITT | BUILDING-RESIDENTIAL | REVIEW | Denied | PLAN CHECK COMMENTS - PROJECT #T03CM04416 10/30/03 719 S. 11TH AVE. PLAN REVIEW FOR THE ABOVE REFERENCED STRUCTURE HAS BEEN COMPLETED. THIS LETTER REFLECTS COMMENTS TO BE ADDRESSED. IN ORDER TO FACILITATE A SHORTER BACK CHECK TIME, WE REQUEST THAT YOU PLEASE PROVIDE REVISED PLANS AND CALCULATIONS, HIGHLIGHTING ANY CHANGES, ALONG WITH A WRITTEN RESPONSE TO EACH OF THE NOTED ITEMS INDICATING ACTION TAKEN. SCOPE OF REVIEW: THE SCOPE OF THIS PLAN REVIEW COVERS ARCHITECTURAL, PLUMBING, MECHANICAL, MODEL ENERGY AND ELECTRICAL CODES. ALL CODE REFERENCES ARE TO THE 2000 IRC AND STATE PLUMBING CODE. ALL FEATURES WERE CHECKED ONLY TO THE EXTENT ALLOWED BY THE SUBMITTALS PROVIDED. ALL PORTIONS OF THIS PROJECT ARE ASSUMED TO MEET OR WILL MEET OTHER DEPARTMENTAL REQUIREMENTS, CONDITIONS AND CONCERNS BEFORE PERMIT APPROVAL. GENERAL REQUIREMENTS: 1. ALL CORRECTIONS AND REVISIONS SHALL BE MADE ON THE ORIGINAL TRACINGS AND TWO NEW SETS OF PRINTS OR (1) SEPIA & (1) BLUE LINE SHALL BE RETURNED ALONG WITH ALL REDLINE PRINTS. 3. PEN OR PENCIL CORRECTIONS ON FINAL PRINTS WILL NOT BE ACCEPTABLE. TO AVOID DELAYS ENSURE ALL CORRECTIONS HAVE BEEN MADE, ARE COMPLETE AND HAVE BEEN COORDINATED ON ALL APPLICABLE DETAILS AND NOTES. SITE PLAN: 1. THE 1-HR. FIRE WALL IS REQUIRED IF THE WALL IS LESS THAN 3' FROM THE PROPERTY LINE. I' VE NOT HEARD OF A FIRE WALL LISTING WITH FOAM BETWEEN THE 3-COAT STUCCO AND THE FRAMING. ALSO, THE WINDOWS WOULD HAVE TO BE LISTED AS APPROVED FOR USE IN A FIRE RATED WALL. STRUCTURAL PLANS: 1. PLEASE SPECIFY THE HEADERS FOR THE FAMILY ROOM AND BED ROOMS. 2. PROVIDE MANUFACTURER'S CALCULATIONS AND DATA FOR PRE-FAB TRUSSES. TRUSS CALCULATIONS MUST BE SIGNED, DATED AND WET-SEALED BY AN ENGINEER WHO IS REGISTERED IN ARIZONA. 3. PLEASE SPEC THE GRADE AND SPECIES OF LUMBER TO BE USED. SECTIONS - DETAILS - MISC. NOTES: 1. DTLS. 1and 3 / 4 ; PLEASE SPEC THE SHEATHING. 2. 4 / 3 ; PLEASE SPEC THE ANCHOR BOLT DIAMETER AND LENGTH. 3. 6 / 3 ; IF THIS IS A FIRE WALL, THE FOAM IS REQUIRED TO HAVE AN EQUIVILENT FIRE RATING. PLEASE PROVIDE A LISTING OR DELETE THE FOAM. 4. 1and 2 / 3 ; NOTE AND SPECIFY THE SIZE, SPACING AND LENGTH OF ANCHOR BOLTS FOR SILL PLATES. 5. BRACED PANEL NOTES / 1 ; ANCHOR BOLTS ARE REQUIRED AT QUARTER POINTS FOR BRACED PANEL B. SEE R602.10.6 . PLUMBING PLANS: 1. THE TRAP ARM OF THE KITCHEN SINK APPEARS TO BE OVER 5' FROM THE VENT. SEE U.P.C. TABLE 10-1 . ELECTRICAL PLANS: 1. A RECEPTACLE IS REQUIRED BETWEEN THE FAMILY ROOM DOOR TO THE PORCH AND THE FAMILY ROOM DOORWAY TO THE LAUNDRY AREA IF IT IS OVER 2' WIDE. 2 . PROVIDE AN EXTERIOR OUTLET AT GRADE LEVEL LOCATED AT BOTH THE FRONT AND BACK OF THE DWELLING, PER E3801.7. THESE OUTLETS SHALL BE GFI PROTECTED PER E3802.3. 3. THE LIGHT FIXTURE IN THE SHOWER AREA IS REQUIRED TO BE LISTED AS APPROVED FOR USE IN A WET AREA. 4. WHERE CEILING FANS ARE SHOWN ON THE PLANS, PROVIDE A NOTE INDICATING ONLY APPROVED OUTLET BOXES SHALL BE USED, PER E4001.6. 5. NOTE THAT LIGHT FIXTURES IN CLOTHES CLOSETS SHALL BE INSTALLED IN ACCORDANCE WITH E3903.11. ENERGY CODE: 1. TUCSON HAS ADOPTED 2100 AS THE "DEGREE DAYS HEATING". I.R.C. TABLE N1102.1's "HDD" COLUMN SHOULD BE USED AS 2100 WHICH INDICATES A MAXIMUM GLAZING U-FACTOR OF .65 . ( SEE THE ENERGY CODE MODIFICATIONS ON THE CITY WEB SITE ) . 2. JUSTIFY TWO DIFFERENT U-VALUES FOR GLAZING ( SINGLE HUNG vs. HORIZ. SLIDER ) . IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT YOUR ASSIGNED PLANS EXAMINER: DAVE WITT @ 791-5550 EXT. 1110 |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 11/03/2003 | CINDY AGUILAR | OUT TO CUSTOMER | Completed |
| 11/03/2003 | ANGIE SHOFFSTALL | REJECT SHELF | Completed |