Permit Review Detail
Review Status: Completed
Review Details: RESUBMITTAL
Permit Number - T03CM04293
Review Name: RESUBMITTAL
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 11/26/2003 | Bruce Stevens | BUILDING-RESIDENTIAL | REVIEW | Denied | PLAN CHECK COMMENTS - PROJECT #T02CM04293 11/28/03 2920 E. Ohio St. PLAN RE-REVIEW FOR THE ABOVE REFERENCED STRUCTURE HAS BEEN COMPLETED. THIS LETTER REFLECTS COMMENTS TO BE ADDRESSED. IN ORDER TO FACILITATE A SHORTER BACK CHECK TIME, WE REQUEST THAT YOU PLEASE PROVIDE REVISED PLANS AND CALCULATIONS, HIGHLIGHTING ANY CHANGES, ALONG WITH A WRITTEN RESPONSE TO EACH OF THE NOTED ITEMS INDICATING ACTION TAKEN. SITE PLAN: 1. RE - SUBMITTED PLAN DOES NOT HAVE ZONING OR FLOODPLANE APPROVAL. 2. FIREPLACES: - DETAIL DOES NOT PROVIDE ENOUGH INFORMATION FOR PLAN REVIEW OR CONSTRUCTION. PLEASE PROVIDE DETAILED CROSS SECTION OF FIREPLACE CONSTRUCTION INCLUDING FOUNDATION AND HEARTH. STRUCTURAL PLANS: 1. PROVIDE MANUFACTURER'S CALCULATIONS AND DATA FOR PRE-FAB TRUSSES AND GLULAM BEAMS. TRUSS CALCULATIONS MUST BE SIGNED, DATED AND WET-SEALED BY AN ENGINEER WHO IS REGISTERED IN ARIZONA. TRUSS CALCULATIONS SHALL BE CROSS-REFERENCED TO THE FLOOR PLANS. ALSO, THE ENGINEER OF RECORD SHALL REVIEW AND "SHOP DRAWING" STAMP APPROVAL ON TRUSS CALCULATIONS. 2. SPECIFY LATERAL SUPPORT OF TRUSSES. 3. DETAIL GABLE END BRACING CONNECTIONS. 4. SPECIFY AND DETAIL ALL ROOF OVER FRAMING. IF SOLID SHEATHING IS USED ON THE LOWER TRUSSES, PROVIDE MINIMUM OPENINGS OF 22" BY 30" FOR ACCESS AND VENTILATION INTO OVER FRAMED AREAS (>30 S.F.). IF SOLID SHEATHING IS NOT USED ON LOWER TRUSSES, PROVIDE DETAILS FOR BRACING OF TOP CHORD OF LOWER TRUSSES. 5. SHOW DETAILS FOR ALL BEARING AND CRITICAL NON-BEARING CONDITIONS. THIS INCLUDES THE HEADER AT THE FIREPLACE CHIMNEY FOR TRUSS SUPPORT. SECTIONS - DETAILS - MISC. NOTES: 1. 6X14 GLU-LAM SPECIFIED ON PLAN DOES NOT EXIST. PROVIDE ACTUAL GLU-LAM SPECIFICATIONS AS WELL AS BEARING AND ATTACHMENT DETAILS. PLUMBING PLANS: 1. SHOW SIZES OF WASTE LINES, VENTS AND REQUIRED CLEANOUTS. (VENTS ARE NOT SHOWN ON PLAN) 2. GAS: PROVIDE THE LENGTH OF LINE TO EACH APPLIANCE, BTU DEMAND OF EACH APPLIANCE, SIZE OF EACH BRANCH, TOTAL DEMAND & TOTAL DEVELOPED LENGTH FROM METER TO MOST REMOTE APPLIANCE ON THE SYSTEM PER UPC 1217.2. WILL EXISTING GAS LINE BE UNDER NEW SLAB? IF SO, IT MUST BE RELOCATED PRIOR TO CONSTRUCTION. ELECTRICAL PLANS: 1. PRIVIDE A PANEL SCHEDULE INCLUDING NEW CIRCIUTS TO BE ADDED. 2. A MINIMUM OF TWO CIRCUITS SHALL BE PROVIDED FOR KITCHEN COUNTER RECEPTACLES. THESE OUTLETS SHALL BE PROVIDED AT EACH KITCHEN COUNTER SPACE WIDER THAN 12", AND SHALL BE INSTALLED SO THAT NO POINT ALONG THE WALL LINE IS MORE THAN 24" FROM A RECEPTACLE OUTLET, PER E3801.4.1 3. ISLAND OR PENINSULA COUNTER TOPS SHALL HAVE AT LEAST ONE RECEPTACLE OUTLET AT EACH COUNTER SPACE WITH A LONG DIMENSION OF 24" OR GREATER, AND A SHORT DIMENSION OF 12" OR GREATER, PER E3801.4.2 AND E3802.4.3. ADDITIONAL OUTLET SHALL BE INSTALLED AT THE PENENSULA INTERSECTION WITH WALL. 20. SHOW LOCATIONS OF SMOKE DETECTORS PER R317. THESE ARE DESIGNED FOR INSTALLATION IN BEDROOMS AND ROOMS ADJACENT TO BEDROOMS. IF CEILING FINISH MATERIAL IS TO BE REMOVED, THEY MUST BE INTERCONNECTED WITH A POWER SOURCE FROM THE BUILDING WIRING, AND SHALL BE EQUIPPED WITH BATTERY BACKUP. MODEL ENERGY CODE: 2. CALL OUT ON THE PLANS THE "R" VALUES OF INSULATION, AS WELL AS THE "U" VALUES OF THE WINDOWS AND DOORS IN CONFORMANCE WITH THE ENERGY CALCULATIONS PROVIDED. R-13 IS NOT POSSIBLE WITH 1" FOAM INSULATION. IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT YOUR ASSIGNED PLANS EXAMINER: BRUCE STEVENS @ 791-5550 EXT. 1112 NOTE: AS OF 2-02-01 THE CITY OF TUCSON HAS ADOPTED THE 2000 IRC EXCEPT FOR THE PLUMBING PORTION WHICH HAS BEEN REPLACED WITH THE STATE PLUMBING CODE. ALL MODEL PLANS SHALL REFERENCE THESE CODES. |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 12/05/2003 | MONICA VALDEZ | OUT TO CUSTOMER | Completed |
| 12/03/2003 | ANGIE SHOFFSTALL | REJECT SHELF | Completed |