Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit Number: T03CM04263
Parcel: 13339795A

Address:
260 S SEWELL PL

Review Status: Completed

Review Details: 3RD PARTY REVIEW-RESIDENTIAL

Permit Number - T03CM04263
Review Name: 3RD PARTY REVIEW-RESIDENTIAL
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
09/15/2003 TACHONG1 WWM REVIEW Needs Review
09/15/2003 WILDAN 3RD PARTY REVIEW-COMMERCIAL REVIEW Denied The initial review for the above project has been completed. This letter reflects comments which need to be addressed by a written response to each, indicating action taken. In order to facilitate a shorter back-check time, we request that you please provide two (2) sets revised plans and calculations, highlighting any changes with appropriate revision number, revision date and "cloud bubbles." Please return redline drawings with your resubmittal.


Occupancy
Occup. Load
Construction
Area S.F.
Sprinklered
Alarms









GENERAL COMMENTS:

1. This project has been reviewed for conformance with the 2000 IBC, 2000 IRC, 1997 UAC, 2000 IMC, 1998 IECC, 1999 NEC codes with local modifications, and the 1994 UPC with State of Arizona Amendments. Any revisions to this plan will require an additional review and approval by Willdan.

2. Provide truss calculations signed and sealed by a licensed registrant in the State of Arizona. Reference IRC R802.10.2.

3. Design of rainwater piping shall be in accordance with IRC R903. Please provide details and calculations.

Sheet 5

1. Provide details of handrails at stairs. Reference IRC R315.

2. Provide details of guards at stairs. Reference IRC R316.

3. Note on plan that Special Inspection is required for the installation of bolt with epoxy. Reference IBC Section 1704.13.

Sheet 7

1. Provide location of electric sub panel. Reference IRC R106.1.

2. Provide smoke alarms complying with IRC R317.1.1.

Sheet 8

1. Provide venting details for gas appliances. Reference IRC R106.1.

2. Provide manufacturer's specifications for cooking appliances. Cooking appliances designed, tested, and labeled for use in commercial occupancies shall not be installed within dwelling units or within any area where domestic cooking operations occur. Reference IMC Section 917.2.
09/15/2003 TACHONG1 NPPO REVIEW Needs Review

Final Status

Task End Date Reviewer's Name Type of Review Description
09/15/2003 TAMI ACHONG OUT TO CUSTOMER Completed