Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

PRO is currently experiencing an outage. Some documents and records may not be available on PRO momentarily. We apologize for the inconvenience and are working to restore full access.

Permit Number: T03CM04172
Parcel: 13322471B

Review Status: Completed

Review Details: 3RD PARTY REVIEW-COMMERCIAL TI

Permit Number - T03CM04172
Review Name: 3RD PARTY REVIEW-COMMERCIAL TI
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
08/27/2003 EROSE1 WWM REVIEW Needs Review
08/27/2003 WILDAN 3RD PARTY REVIEW-COMMERCIAL REVIEW Denied GENERAL COMMENTS:

1. This project has been reviewed for conformance with the 2000 IBC, 1997 UAC, 2000 IMC, 1998 IECC, 1999 NEC codes with local modifications, and the 1994 UPC with State of Arizona Amendments. Any revisions to this plan will require an additional review and approval by Willdan.


ARCHITECTURAL COMMENTS:

Sheet A2.1

1. Guardrail construction at elevated surfaces and stairs requires special construction and edge protection. Review and clarify proposed guardrail. Reference IBC Sections 1003.2.12 and 1003.3.4.8.

2. Handrail shall have not less than 1.5 inches clearance. Provide clearance dimension. Reference IBC Section 1003.3.3.11.6.

Sheet A4.0

1. Coordinate hardware schedule numbers with itemization list. Reference IBC Section 106.1.1.

2. EIFS systems without a weather resistive barrier require special inspection. Review and clarify EIFS construction, and coordinate all drawings and details. Reference IBC Sections 1704.12 and 1404.2.

3. Exit doors shall be openable from the inside without the use of a key, special knowledge, or effort. The main entrance may be provided with a cylinder lock provided that an applicable designated sign is provided: "This Door To Remain Unlocked When Building Is Occupied." Clarify compliance for egress at all exit doors. Reference IBC Section 1003.3.1.8.

4. Designate each pane, which is required to be safety-glazed. Reference IBC Section 2406.


STRUCTURAL COMMENTS:

Sheet S0.1

1. Special Inspections are called-out for field welding. Provide the City of Tucson required documentation. Reference IBC Section 1704.


PLUMBING COMMENTS:

The plumbing portion was not a part of this review.


MECHANICAL COMMENTS:

The mechanical portion was not a part of this review.


ELECTRICAL COMMENTS:

The electrical portion was not a part of this review.


ENERGY CODE COMMENTS:

The energy code portion was reviewed and accepted.


ACCESSIBILITY COMMENTS:

The accessibility portion was reviewed and accepted.
08/27/2003 EROSE1 WATER REVIEW Needs Review
08/27/2003 EROSE1 FIRE REVIEW Needs Review

Final Status

Task End Date Reviewer's Name Type of Review Description
08/27/2003 ELAINE ROSE OUT TO CUSTOMER Completed