Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

PRO is currently experiencing an outage. Some documents and records may not be available on PRO momentarily. We apologize for the inconvenience and are working to restore full access.

Permit Number: T03CM04140
Parcel: 125100730

Review Status: Completed

Review Details: OTHER

Permit Number - T03CM04140
Review Name: OTHER
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
09/10/2003 MELISSA POULIN WWM REVIEW Approved
09/17/2003 DAVE WITT BUILDING-RESIDENTIAL REVIEW Denied PLAN CHECK COMMENTS - PROJECT #T03CM04140

9/21/03 3744 E. CALLE BARCELONA

PLAN REVIEW FOR THE ABOVE REFERENCED STRUCTURE HAS BEEN COMPLETED. THIS LETTER REFLECTS COMMENTS TO BE ADDRESSED. IN ORDER TO FACILITATE A SHORTER BACK CHECK TIME, WE REQUEST THAT YOU PLEASE PROVIDE REVISED PLANS AND CALCULATIONS, HIGHLIGHTING ANY CHANGES, ALONG WITH A WRITTEN RESPONSE TO EACH OF THE NOTED ITEMS INDICATING ACTION TAKEN.

SCOPE OF REVIEW:

THE SCOPE OF THIS PLAN REVIEW COVERS ARCHITECTURAL, PLUMBING, MECHANICAL, MODEL ENERGY AND ELECTRICAL CODES. ALL CODE REFERENCES ARE TO THE 2000 IRC AND STATE PLUMBING CODE. ALL FEATURES WERE CHECKED ONLY TO THE EXTENT ALLOWED BY THE SUBMITTALS PROVIDED. ALL PORTIONS OF THIS PROJECT ARE ASSUMED TO MEET OR WILL MEET OTHER DEPARTMENTAL REQUIREMENTS, CONDITIONS AND CONCERNS BEFORE PERMIT APPROVAL.

GENERAL REQUIREMENTS:

1. ALL PLANS SHALL BE LEGIBLE AND A SCALE NO SMALLER THAN ¼ INCH = 1-FOOT SHALL BE USED
FOR ALL FLOOR PLANS, FRAMING PLANS AND ELEVATIONS. DETAILS &CROSS SECTIONS AT A MINIMUM 3/8 INCH = 1-FOOT SCALE.

2. ALL CORRECTIONS AND REVISIONS SHALL BE MADE ON THE ORIGINAL TRACINGS AND TWO NEW SETS OF PRINTS OR (1) SEPIA & (1) BLUE LINE SHALL BE RETURNED ALONG WITH ALL REDLINE PRINTS.

3. PEN OR PENCIL CORRECTIONS ON FINAL PRINTS WILL NOT BE ACCEPTABLE. TO AVOID DELAYS ENSURE ALL CORRECTIONS HAVE BEEN MADE, ARE COMPLETE AND HAVE BEEN COORDINATED ON ALL APPLICABLE DETAILS AND NOTES.

FOUNDATION PLANS:

1. DTL. D/2 ; THE MINIMUM FOOTING WIDTH FOR A MASONRY WALL IS 19". I COULDN'T FIND THE ENGINEER'S JUSTIFICATION FOR THE 16" FOOTING.

FLOOR PLANS:

1. HOW DOES THE DEN/STUDIO COMPLY WITH R303.1 EXCEPTION #1 ? VENTILATION IN LIEU OF WINDOWS.

2. PLEASE IDENTIFY THE HEIGHT OF THE EQUIPMENT PLATFORM IN THE GARAGE.

STRUCTURAL PLANS:

1. ROOF FRAMING / 4 ; PLEASE CLARIFY THE "(1) 1 ½"X8"X18" L-ANGLE" AT THE #2 BATHROOM WINDOW.

2. ROOF FRAMING / 4 ; THE ENGINEER'S CALC'S, PAGE 13, SPECIFY 16 GA. BETWEEN THE GREAT ROOM AND THE MASTER BEDROOMBUT THE PLANS CALL FOR 18 GA. PLEASE CLARIFY.

3. ROOF FRAMING / ENGINEER'S CALC'S. ; THE THICKNESS OF THE#7 ANGLE IRON LINTEL WAS CUT OFF.

SECTIONS - DETAILS - MISC. NOTES:

1. PLEASE JUSTIFY THE UNREINFORCED PARAPET.

2. DTL. A / 4 ; PLEASE SPECIFY THE LENGTH OF THE EXPANSION BOLTS. …….3/8"?

PLUMBING PLANS:

1. PLEASE INCLUDE THE LOG LIGHTER IN THE "BTU REQUIREMENTS" CHART.

2. JUSTIFY THE 1 ¼" GAS SERVICE LINE IN ACCORD WITH U.P.C. TABLE 12-3 .

3. JUSTIFY THE ¾" GAS TO THEFURNACE.

4. JUSTIFY ½" GAS TO THE DRYER.

5. PLEASE SIZE THE GAS LINE BETWEEN THE FIRST "T" AND THE APPLIANCES BOTH WAYS. DON'T FORGET THE OPTIONAL OVEN.

6. THE TOTAL DEVELOPED LENGTH OF THE WATER DISTRIBUTION IS REQUIRED TO BE MEASURED TO THE MOST REMOTE APPLIANCE. SEE U.P.C. 610.7,ITEM (2). PLEASE DOUBLE CHECK THE PIPE SIZES.

7. PLEASE SPEC. THE WATER METER SIZE.

MECHANICAL PLANS:

1. THE RETURN AIR IS REQUIRED TO BE SIZED PER M1602 MINIMUM. DUCTS AND GRILLS ARE TO BE NET SIZES.

ELECTRICAL PLANS:

1. PLEASE PROVIDE SMOKE DETECTORS IMMEDIATELY OUTSIDE THE SLEEPING ROOMS. SEE R317.1, ITEM 2.



IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT YOUR ASSIGNED PLANS EXAMINER:
DAVE WITT @ 791-5550 EXT. 110

Final Status

Task End Date Reviewer's Name Type of Review Description
09/22/2003 CINDY AGUILAR OUT TO CUSTOMER Completed
09/22/2003 ANGIE SHOFFSTALL REJECT SHELF Completed