Permit Review Detail
Review Status: Completed
Review Details: COMMERCIAL NEW
Permit Number - T03CM04068
Review Name: COMMERCIAL NEW
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 08/28/2003 | Robert Sherry | MECHANICAL-COMMERCIAL | REVIEW | Passed | |
| 08/28/2003 | ROBERT SHERRY | PLUMBING-COMMERCIAL | REVIEW | Denied | 1. Provide specifications for backflow preventer noted on Sheet 16 2. Provide shut-off valve for water supply to modular restroom. Reference Section 605.0, UPC 1994. 3. Label size of water supply pipe feeding modular restroom (Sheet 16). |
| 08/28/2003 | ROBERT SHERRY | WATER | REVIEW | Approved | |
| 09/04/2003 | DOUG LAAKSO | BUILDING-COMMERCIAL | REVIEW | Denied | 1. PROVIDE DETAILS ON DRAWINGS FOR ACCESSIBILITY AT PARKING, ACCESS RAMPS, LANDINGS, WITH SLOPES, ELEVATIONS, AND LOCATIONS, REF. DRAWING #14 AND #15, PER IBC SEC #11. ........................................... ...... 2. PROVIDE COPY OF STRUCTURAL CALCULATIONS FOR FOUNDATIONS. .................................................. .......... 3. PROVIDE TWO SETS OF APPROVED SHOP DRAWINGS FOR : 1. RESTROOMS ...................................................... 2. CHAINLINK FENCING .......................................... 4. PROVIDE INSPECTION PROGRAM PER 1997 UAC SEC 302.5. ............................................................................. 5. SPECIAL INSPECTION REQUIRED FOR : . 1. FOUNDATION EXCAVATIONS . 2. CONCRETE . 3. BOLTS IN CONCRETE . 4. REINFORCING. |
| 09/16/2003 | JIM EGAN | FIRE | REVIEW | Approved | |
| 09/16/2003 | LOREN MAKUS | ENGINEERING | REVIEW | Denied | DATE: September 22, 2003 TO: Mr. Walt Rogers, The Acacia Group SUBJECT: Udall Park Improvements Site and Grading Plan Review REVIEWER: Loren Makus ACTIVITY NUMBER: T03CM04068 and T03BU02138 SUMMARY: The Site Plan and Grading Plan were reviewed by Development Services Department, Engineering Division. The Site Plan and Grading Plan were not approved at this time. Please address the following comments. Site Plan and Grading Plan Comments: 1) Provide a site plan with lot dimensions and bearings (including basis of bearing), sight visibility triangles and points of egress and ingress. (Per Development Standard 2-02.2.1.A) 2) Revise the sheet index on page 13 to be consistent with the page numbers of the plan set. Revise the site plan so that all of the type is 12 point or larger. 3) Clarify the extent of the disturbed area. Give the area in acres or square feet. SWPPP Comments: 4) Show how the undisturbed protected areas will be marked to prevent inadvertent disturbance. 5) Clarify the extent of the disturbed area. Give the area in acres or square feet. Ensure that this number matches the information on the Site Plan Revise the site plan to address all of these comments and resubmit two copies for review. Include a letter explaining how each comment has been addressed. Loren Makus Senior Engineering Associate Engineering Division Development Services |
| 09/22/2003 | Linda Buczynski | ELECTRICAL-COMMERCIAL | REVIEW | Approved | |
| 09/23/2003 | GERRY KOZIOL | WWM | REVIEW | Approved | |
| 10/02/2003 | PETER MCLAUGHLIN | ZONING | REVIEW | Denied | Site plan approval required |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 10/20/2003 | TAMI ACHONG | OUT TO CUSTOMER | Completed |
| 10/20/2003 | ANGIE SHOFFSTALL | REJECT SHELF | Completed |