Permit Review Detail
Review Status: Completed
Review Details: COMMERCIAL-BLDG/FIRE ONLY
Permit Number - T03CM04053
Review Name: COMMERCIAL-BLDG/FIRE ONLY
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 08/15/2003 | ANY | BUILDING-COMMERCIAL | REVIEW | Denied | .. T03CM04053 .. 6310 E TANQUE VERDE RD .. DGL .. 8/15 .. S1) PROVIDE DOCUMENTS WITH A MINIMUM OF 10 POINT FONT, FOR REVIEW AND RECORD PURPOSES. ...... . S2) PROVIDE A SITE PLAN BY THE ARCHITECT OF RECORD ADDRESSING BUILDING CODE REQUIREMENTS. .. S3) LOCATE WORK COVERED BY THIS PERMIT AND CUT SECTIONS/DETAILS ON PLAN. ......................................... . S4) PROVIDE SPECIFICATIONS, CALCULATIONS AND DETAILS FOR CONNECTION OF CANVAS TO FRAMING. ..... .. S5) CLARIFY PROTECTION TO PREVENT DETERIORATION OF STRUCTURAL MEMBERS. ................. .. S6) PROVIDE DETAILS AND CALCULATIONS FOR TWO AWNINGS ON NORTH SIDE OF BUILDING. ........................ .. S7) SPECIAL INSPECTION REQUIRED : .................... ........ 1. FIELD WELDING .................... ........ 2. LOCATION OF REINFORCING IN EXISTING CMU WALLS, DETAILS 1/1 AND 4/1. ........................................ ........ 3. EPOXY ANCHORS ..................... ........ 4. EXPANSION ANCHORS .................... .. S8)CLARIFY EXITING FROM BUILDING W/ ADDITION IN PLACE,IBC SEC 10. ......................................................... .. S9) CLARIFY EXIT ILLUMINATION, IBC SEC 10. ............ . ..S10) CLARIFY HOW ACCESSIBILITY IS IMPROVED WITH THIS ADDITION PER IBC SEC 11 & 34. .............................. ..S11) NOTE ON PLAN SIGNS MUST BE SUBMITTED SEPARATELY. ............................ ..S12) PROVIDE COMPLETED CODE REVIEW CHECKLIST, SEE ATTACHMENT. ............................. ..S13) SHOW ADDRESS PER IBC SEC 501. ........... ..S14) PROVIDE ADDRESSING PER PIMA COUNTY ADDRESSING ORDINANCE, SEE ATTACHMENT. ............... ..S15) SHOW AND JUSTIFY MINIMUM PLUMBING FIXTURES. IBC SEC 29. .................................................. ..S16) PROVIDE COMPLETED COMMERCIAL PLAN SUBMITTAL CHECKLIST, SEE ATTACHMENT. |
| 08/15/2003 | DAN CASTRO | ZONING | REVIEW | Approved | |
| 08/18/2003 | JIM EGAN | FIRE | REVIEW | Approv-Cond | Fire sprinklers required under exterior canopy. separate permits/submittals required. |
| 08/25/2003 | Robert Sherry | MECHANICAL-COMMERCIAL | REVIEW | Passed | |
| 08/27/2003 | Linda Buczynski | ELECTRICAL-COMMERCIAL | REVIEW | Passed |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 08/28/2003 | DELMA ROBEY | OUT TO CUSTOMER | Completed |