Permit Number: T03CM03878
Parcel: 12801003A

Address:
240 S WILMOT RD

Review Status: Completed

Review Details: SITE

Permit Number - T03CM03878
Review Name: SITE
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
01/30/2004 JIM EGAN FIRE REVIEW Approved
03/29/2004 Andrew Connor NPPO REVIEW Approved
04/05/2004 Joseph Linville LANDSCAPE REVIEW Denied 1) Revise the landscape plan to include changes made to the site plan. DS 2-07.2.1.A

2) Revise all plans to eliminate situations where parked vehicles may overhang the required 10' wide street landscape border along Wilmot Road. DS 2-06.3.3.E

3) Revise the plans to identify the property lines and include dimensions for the street landscape borders. The border is required to be a minimum of ten feet wide as measured from the property line or MS&R right of way line. LUC 3.7.2.4.A.1

4) Correctly identify Wilmot Road on the site plans.
DS 2-02.2.1.A.18

5) Revise the site plans to locate screen walls per LUC 3.7.3.2.C.3. Wall encroachment into the street landscape border is limited to three feet.

6) Revise the site and landscape plans to include the same size planters, (sheets A07 & L7). DS 2-07.2.2.A.2.e, DS 2-07.2.1.A

7) Clarify if the LA Fitness building is future as labeled on the revised site plan or included as part of phase one development.

8) Revise sheet note 16 on A02. The landscape materials and other structures are to be less than 30" in height.
DS 3-01.5.1.A.1

9) Revise the site plan to include all required screening elements along Park Place Drive. Refer to sheet L5.
DS 2-07.2.1.A.27
04/05/2004 DAN CASTRO HANDICAP-SITE REVIEW Denied Refer to Zoning review comment one (1).
04/05/2004 DAN CASTRO ZONING REVIEW Denied 1. It appears that the gross floor area has been reduced. Provide all applicable calculations on the revised site plan (i.e. floor area ratio, vehicle, handicap, and bicycle parking, loading).

2. Provide a statement on the revised site plan or by separate letter describing the revisions made.
04/07/2004 Loren Makus ENGINEERING REVIEW Approved

Final Status

Task End Date Reviewer's Name Type of Review Description
04/09/2004 LISA LESNY OUT TO CUSTOMER Completed
04/08/2004 ANGIE SHOFFSTALL REJECT SHELF Completed