Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Number: T03CM03786
Parcel: 113061240

Address:
1630 E LIND RD

Review Status: Completed

Review Details: RESIDENTIAL BLDG/WWM

Permit Number - T03CM03786
Review Name: RESIDENTIAL BLDG/WWM
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
09/16/2003 DAVE WITT BUILDING-RESIDENTIAL REVIEW Denied PLAN CHECK COMMENTS - PROJECT #T03CM03786

9/15/03 1630 E. LIND RD.

PLAN REVIEW FOR THE ABOVE REFERENCED STRUCTURE HAS BEEN COMPLETED. THIS LETTER REFLECTS COMMENTS TO BE ADDRESSED. IN ORDER TO FACILITATE A SHORTER BACK CHECK TIME, WE REQUEST THAT YOU PLEASE PROVIDE REVISED PLANS AND CALCULATIONS, HIGHLIGHTING ANY CHANGES, ALONG WITH A WRITTEN RESPONSE TO EACH OF THE NOTED ITEMS INDICATING ACTION TAKEN.

SCOPE OF REVIEW:

THE SCOPE OF THIS PLAN REVIEW COVERS ARCHITECTURAL, PLUMBING, MECHANICAL, MODEL ENERGY AND ELECTRICAL CODES. ALL CODE REFERENCES ARE TO THE 2000 IRC AND STATE PLUMBING CODE. ALL FEATURES WERE CHECKED ONLY TO THE EXTENT ALLOWED BY THE SUBMITTALS PROVIDED. ALL PORTIONS OF THIS PROJECT ARE ASSUMED TO MEET OR WILL MEET OTHER DEPARTMENTAL REQUIREMENTS, CONDITIONS AND CONCERNS BEFORE PERMIT APPROVAL.

GENERAL REQUIREMENTS:

1. ALL PLANS SHALL BE LEGIBLE AND A SCALE NO SMALLER THAN ΒΌ INCH = 1-FOOT SHALL BE USED
FOR ALL FLOOR PLANS, FRAMING PLANS AND ELEVATIONS. DETAILS &CROSS SECTIONS AT A MINIMUM 3/8 INCH = 1-FOOT SCALE.

2. ALL CORRECTIONS AND REVISIONS SHALL BE MADE ON THE ORIGINAL TRACINGS AND TWO NEW SETS OF PRINTS OR (1) SEPIA & (1) BLUE LINE SHALL BE RETURNED ALONG WITH ALL REDLINE PRINTS.

3. PEN OR PENCIL CORRECTIONS ON FINAL PRINTS WILL NOT BE ACCEPTABLE. TO AVOID DELAYS ENSURE ALL CORRECTIONS HAVE BEEN MADE, ARE COMPLETE AND HAVE BEEN COORDINATED ON ALL APPLICABLE DETAILS AND NOTES.

FOUNDATION PLANS:

1. PROVIDE A FOOTING FOR THE FURNACE ROOM.

2. THE 4' X 10" FOOTING AT THE NORTH END OF THE GLU-LAM APPEARS TO BE INADEQUATE.

FLOOR PLANS:

1. LABEL ALL ROOMS AND SPACES. SHOW ALL DOORS. SHOW ENTIRE FLOOR PLAN.

2. HOW WILL THE 3-2X4's SUPPORT THE FULL WIDTH OF THE GLU-LAM?

3. HOW WILL THE 4' X 10" FOOTING BE USED WITH THE CONTINUOUS FOOTING AT THE SOUTH END OF THE GLU-LAM? JUSTIFY THE .150 IN THE CALCULATIONS.

SECTIONS - DETAILS - MISC. NOTES:

1. DTL. 1 / 2 ; PROVIDE WEEP HOLES. SEE R703.7.6

2. DTL. 1 /2 ; PROVIDE FLASHING . SEE R703.7.5

3. DTL. 2 /2 ; ANCHOR BOLTS REQUIRE 7" MINIMUM PENETRATION.

4. DTL. 2 / 2 ; PLEASE DESCRIBE THE INSIDE WALL COVERING AND OUTSIDE WALL SHEATHING.

5. PLEASE DESCRIBE THE POST TO BEAM CONNECTION.

6. DTL. 1 / 4 ; SHOULD THE FRIEZE BOARDS BE VENTED?

7. DTL. 1 / 5 ; HOW WILL THE SIMPSON H11Z , 2- 9/16" WIDE , ACCOMMODATE THE 3-1/2" WIDE 4 X 6 ?



MECHANICAL PLANS:

1. PLEASE PROVIDE RETURN AIR . SEE M1602 ; M1602.2 FOR MINIMUM SIZE.


ELECTRICAL PLANS:

1. PROVIDE SMOKE DETECTORS FOR THE EXISTING SLEEPING AREAS . SEE R317.1.1 .






IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT YOUR ASSIGNED PLANS EXAMINER:
DAVE WITT @ 791-5550 EXT. 1110

Final Status

Task End Date Reviewer's Name Type of Review Description
09/17/2003 TAMI ACHONG OUT TO CUSTOMER Completed
09/16/2003 ANGIE SHOFFSTALL REJECT SHELF Completed