Permit Number: T03CM03722
Parcel: 10409001C

Address:
4365 N ORACLE RD

Review Status: Completed

Review Details: SITE

Permit Number - T03CM03722
Review Name: SITE
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
07/28/2003 JIM EGAN FIRE REVIEW Approved
08/20/2003 Paul Machado SANITATION REVIEW Denied Approved development plan required.
08/20/2003 Paul Machado ENGINEERING REVIEW Denied To: Skyline Consultants
Jason Allen
111 W. Monroe St., Ste. 1122
Phoenix, Arizona 95003

SUBJECT: 4365 N. Oracle Road
Site Plan T03CM03722 (First Review)
T13S, R13E, Section 23

RESUBMITTAL REQUIRED: Site Plan and Drainage Report.

The Site Plan (SP) and Drainage Report (DR) cannot be approved as submitted. Please address the following review comments prior to the next submittal.

Site Plan:

1. Please include a response letter to the comments along with the corrected copies with re-submittal.
2. The comments for the SP are the identical comments for the Development plan (First review). The comments for the SP will be satisfied when the Development plan has been revised per these comments. Submit copies of the approved Development plan as the Site plan for approval.
3. The comments for the DR should also be satisfied when the Development plan is approved.
4. An approved Development Plan is required prior to the approval of the Site plan.
5. Label existing and future sight visibility triangles per D.S. 2-02.2.1.10.
6. A grading plan will be required.
7. Show all points of egress and ingress including locations and width of driveways and parking area access lanes (P.A.A.L.) per D.S. 2-02.2.1.11. Dimension ingress at the SE corner of the site.
8. Please provide Drainage patterns and finished grades per D.S. 2-02.2.1.16.
9. Please list estimated cut & fill quantities per D.S. 2-02.2.1.17.
10. Please show dimensioned right-of-way, including any applicable Major Streets and Routes (MS&R) Plan right-of-way per D.S. 2-02.2.1.19. The future right-of-way width for Wetmore Road is 120'. Please correct.
11. Add the basin(s) maintenance responsibility note per S.M.D.D.F.M. 2.3.1.6 C 1 and 2 to the SP.
12. Dimension from street monument lines to existing and proposed curbs, sidewalks, driveways, and utility lines per D.S. 2-02.2.1.21.
13. Please provide existing topographic contours at intervals not exceeding two (2) feet and/or spot elevations as pertinent and Bench Mark based on City of Tucson Datum, including City Field Book and page number per D.S. 2-02.2.1.23.
14. A private improvement agreement will be necessary for the deceleration lane proposed within the Right-of-way. Contact Permits and Codes at (520) 791-5100 for PIA information. An approval from ADOT concerning the deceleration lane is required prior Development plan approval.
15. Please show the proposed roof drainage patterns, 100% of the 10-year flow must be conveyed under the sidewalks. Please provide supporting calculations to demonstrate compliance with D.S. 3-01.4.4. If the location(s) of the roof scuppers have not yet been decided, a general note indicating sidewalk scuppers will be used when the roof scuppers locations have been designed and located will suffice.
16. Add note: "Depress all landscaped areas 6" maximum for water harvesting".
17. A Stormwater pollution prevention plan is required. Contact Paul P. Machado at 791-5550 x1193 for additional information.

Drainage Report:
1. Please include a comment letter along with the next submittal.
2. It must be shown that the remainder of the basin will sufficiently retain the 5 year threshold amount of storm water.
3. The Drainage report was reviewed for Development plan purposes only.
4. The Drainage report cannot be accepted as is. Content and format of Drainage report should follow the requirements per S.M.D.D.F.M., chap. II, 2.3.1. A S.M.D.D.F.M is available through this web site: http://tdotmaps.transview.org/mandr/Download/
5. A $150.00 review fee for the Drainage Report is required.
6. Please show the project address on the cover of the Drainage report.
7. Add the basin(s) maintenance responsibility note per S.M.D.D.F.M. 2.3.1.6 C 1 and 2 to the DR.

If you have any questions, I can be reached at 791-5550 x1193 or pmachad2@ci.tucson.az.us
Paul Machado
Senior Engineering Associate
08/25/2003 PETER MCLAUGHLIN HANDICAP-SITE REVIEW Denied See zoning review comments.
08/25/2003 PETER MCLAUGHLIN ZONING REVIEW Denied SITE PLAN TRANSMITTAL

TO: Jason Allen, Skyline Consultants
111 W. Monroe Street, #1122
Phoenix, AZ 85003
(602) 324-5330

FROM: Peter McLaughlin
Senior Planner
Development Services Dept.

FOR: Patricia Gehlen
Principal Planner
Development Services Dept.

PROJECT:
T03CM03722
Eckerd Drugstore
4365 N. Oracle Road
Site Plan Review

TRANSMITTAL: August 25, 2003

COMMENTS:


1. A development plan (D03-021) for this project is currently under review and must be approved prior to site plan approval.

If you have any questions about this transmittal, please call Dan Castro or Peter McLaughlin, (520) 791-5608.
09/15/2003 MVALDEZ1 NPPO REVIEW Needs Review
09/15/2003 MVALDEZ1 LANDSCAPE REVIEW Needs Review

Final Status

Task End Date Reviewer's Name Type of Review Description
09/15/2003 MONICA VALDEZ OUT TO CUSTOMER Completed