Review Details: COMMERCIAL TI
Permit Number - T03CM03572
Review Name: COMMERCIAL TI
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 07/21/2003 | JIM EGAN | FIRE | REVIEW | Approved | |
| 07/21/2003 | DAN CASTRO | ZONING | REVIEW | Approved | |
| 07/21/2003 | PATRICIA GILBERT | ENGINEERING | REVIEW | Approved | |
| 07/22/2003 | ROBERT SHERRY | PLUMBING-COMMERCIAL | REVIEW | Denied | 1. Clarify the difference between P-6 in the Nurse's room and P-6 in the break room. A 2-compartment sink will have 3 waste fixture units and 4 water fixture units. 2. A service sink with a 3" trap (P-4) has 6 waste fixture units. 3. Coordinate the riser diagram (detail 4/P1) with the floor plans. 4. Include all of the fixtures in the fixture unit calculations (e.g. existing hose bibb). 5. Coordinate the riser diagram in detail 2/P1 with the floor plans. 6. Based on your calculations, the CW pipe at keynote 2, and the CW and HW pipes downstream of the WH-1 connection are undersized. 7. The mop sink, P-4, is not an approved termination point for the excess pressure relief for the water heater. |
| 07/22/2003 | MARTIN HAEBERLE | BUILDING-COMMERCIAL | REVIEW | Approved | |
| 07/22/2003 | ROBERT SHERRY | WATER | REVIEW | Approved | |
| 07/22/2003 | LINDA BUCZYNSKI | ELECTRICAL-COMMERCIAL | REVIEW | Approved | 072203 denied |
| 07/22/2003 | ROBERT SHERRY | MECHANICAL-COMMERCIAL | REVIEW | Denied | 1. Provide ventilation calculations conforming to able 403-3, IMC 2000. Exception to Section 403.3 can apply only if a statistical study of the conditions is presented. Indicate the occupancy classification and estimatyed maximum occupancy used for each space on your calculation table. 2. Provide ventilation for the janitor's room (Utility Space). 3. Indicate which a/c units are serving specific areas on the Chapter 4 compliance chart. |
| 07/23/2003 | MELISSA POULIN | WWM | REVIEW | Approved |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 07/23/2003 | MONICA VALDEZ | REJECT SHELF | Completed |
| 07/23/2003 | MONICA VALDEZ | OUT TO CUSTOMER | Completed |