Permit Number: T03CM03500
Parcel: 12511199B

Review Status: Completed

Review Details: SITE

Permit Number - T03CM03500
Review Name: SITE
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
09/15/2003 Blanca Espino ENGINEERING REVIEW Denied Site Plan
1. Indicate lot bearings along with dimensions. D.S. 2-02.2.1.A.5

2. Indicate all proposed buildings and structures, including location, size, height, overhangs, roof slope and downspouts. D.S. 2-02.2.1.A.6

3. Indicate existing sight visibility triangles from PAAL/street. Near 185', Far 110'. D.S. 2-02.2.1.A.10

4. A 5 foot sidewalk from street to buildings is required and it cannot cross behind parking spaces. D.S. 2-02.2.1.A.12 The sidewalk shall be designed and constructed to convey the 10 year flood flow under the sidewalk. D.S. 3-01.4.4.F

5. Indicate location, type, size and height of existing and proposed signage, if applicable. D.S. 2-02.2.1.A.13

6. Indicate drainage patterns with flow arrows, proposed finish floor elevation(s) and finish grades. D.S. 2-02.2.1.A.16

7. Indicate estimated cut and fill quantities. D.S. 2-02.2.1.A.17

8. Indicate if street is "Public" or "Private". D.S. 2-02.2.1.A.18

9. Indicate dimensioned right-of-way, including any applicable Major Streets and Routes (MS&R) Plan right-of-way. D.S. 2-02.2.1.A.19

10. Indicate, if applicable, all easements of record must be graphically shown on the plan together with recording docket and page reference. D.S. 2-02.2.1.A.20

11. Indicate dimension from street monument lines to all existing and proposed curbs, sidewalks, driveways and utility lines. D.S. 2-02.2.1.A.21

12. Indicate existing topographic contours at intervals not exceeding two (2) feet and/or spot elevations as pertinent and Bench Mark based on City of Tucson Datum, including City Field Book and page number. D.S. 2-02.2.1.A.23

13. An adequate and safe ingress/egress is required for the collection vehicle in each new project. D.S. 6-01.3.1.A Indicate refuse container location, size and access thereto fully dimensioned. D.S. 2-02.2.1.A.32 You may contact John Clark with Solid Waste at 791-5414 ext.1004 for curb side service.

14. A driveway apron is required as per PC/COT Standard Detail 206
09/15/2003 Blanca Espino SANITATION REVIEW Denied 1. An adequate and safe ingress/egress is required for the collection vehicle in each new project. D.S. 6-01.3.1.A Indicate refuse container location, size and access thereto fully dimensioned. D.S. 2-02.2.1.A.32 You may contact John Clark with Solid Waste at 791-5414 ext.1004 for curb side service.
10/14/2003 Joseph Linville LANDSCAPE REVIEW Denied 1) Revise the landscape plan to include the content specified in DS 2-07.0, the landscape plan content and format standard.

A) Include the sizes of plants indicated in boxes, gallon cans, or flats or by height (palms), number of canes (ocotillo), or number of pads (opuntia).

B) Include both the proper and common name of each type of plant material.

C) Identify materials and areas of inert ground cover. Per LUC 3.7.2.7, "All disturbed, grubbed, graded, or bladed areas not otherwise improved shall be landscaped, reseeded, or treated with an inorganic or organic ground cover to help reduce dust pollution."

D) The methods by which water harvesting or storm water runoff is used to benefit the oasis allowance area and other planting areas on the site. LUC 3.7.4.3.B

E) An irrigation plan shall be submitted together with the landscape plan. LUC 3.7.4.5.C
Landscape plans shall incorporate water-conserving designs.
LUC 3.7.4.1

F) Include a legend for the symbols used on the plan. DS 2-07.2.2.

2) The refuse storage area is to be screened from the street. Per LUC Table 3.7.2-I a six-foot high screen is required.

3) Per LUC 3.7.2.4., "Fifty (50) percent or more of the area of the street landscape border must be covered with shrubs or
vegetative ground cover. Revise the landscape plans to show the required groundcover plantings and revise the notes as necessary.

4) An interior landscape border is required between the building on the site and the residentially zoned property to the north. See LUC Table 3.7.2-I and LUC 3.7.2.4.B.3.

5) Provide a pedestrian path from the sidewalks on the site to the refuse storage area that continues to the pickup location on Richey Boulevard.

6) Per DS 3-05.2.2.B.3 A minimum distance of two (2) feet must be maintained between a PAAL and any wall, screen, or other obstruction, provided pedestrian activity is
directed to another location. Revise the plans as necessary to provide the minimum clearance.

7) A native plant preservation plan or application for exception is required. Modifications to the plan may be necessary based on plant preservation requirements.
10/16/2003 JOE LINVILLE NPPO REVIEW Denied A native plant preservation plan or application for exception is required. Plans will not be accepted for an additional review without the required information. LUC 3.8, DS 2-15.0
10/20/2003 David Rivera ZONING REVIEW Denied DSC TRANSMITTAL

FROM: David Rivera
Senior Planner

FOR: Patricia Gehlen
Principal Planner

PROJECT: T03CM03500
808 N Richey Boulevard
Tri-plex Multi-family Residential Use DD - K
Site Plan

Transmittal date: 1st Review October 20, 2003

COMMENTS: Please attach a response letter with the next submittal, which states how all Zoning Review Section comments regarding the Land Use Code and Development Standards were addressed.

1. Per a 1998 aerial which is on line through the City of Tucson Transportation web site it is clear that there are several existing structures on the parcel. Please clarify by response comment if any of the existing structures are to remain or used for this new development. If all existing structures on site are to be removed please add a general note that states " that all existing structures are to be demolished". DS 2-02.2.1.A.6

2. The actual building height could not be verified. Elevation drawings or cross sections were not included with the site plan. In order to verify the building setbacks copies of the drawings as mentioned above must be included with the next site plan submittal packet. The building height must also be listed on the plan. See redlines for comments related to this issue. A calculation with a number (assumed bldg. hgt.) on the plan for the side yard and front yard building setbacks has been listed but the height must be verified by reviewing the elevation drawings. DS 2-02.2.1.A.7

3. Dimension the parking spaces including the garage spaces. Per DS 3-05.2.1.B.3, when the sides of a vehicle parking space abuts a vertical barrier over six (6) inches in height other than a vertical support for a carport the required width for a parking space is ten (10) feet. Parking space #2 must be ten (10) feet wide. Revise as required.

A minimum distance of two (2) feet must be maintained between a PAAL and wall, screen or other obstruction, DS 3-05.2.2.B.3. A 26-foot wide PAAL area, which includes the additional 2 feet separation between the PAAL and the wall, is required. DS 2-02.2.1.A.8

In addition back-up spurs are required at the end of a row of parking spaces if no ingress or egress is provided at that end. Back-up spurs are required at both ends of parking spaces 6 and 7. See DS. 3-05.2.2.D for information regarding the depth and the radius of the back-up spurs. DS 2-02.2.1.A.11

4. The sight visibility triangles at the driveway entrance must be drawn based on the existing curb location. Also, please dimension the driveway entrance. DS 2-02.2.1.A.10, DS 2-02.2.1.A.11

5. Per DS 2-08.4.1.F, Sidewalks or pedestrian refuge areas may not be located between any motor vehicle parking space and the PAAL providing access to that space. The proposed sidewalk location has been placed between the parking space and the PAAL and does not meet the development standard criteria. Unfortunately there is also a requirement for five-foot pedestrian refuge area between a PAAL and an enclosed structure. The two development standards seem to contradict each other but the fact that the garages are also proposed and the location of parking spaces one and two make both standards applicable. In order to allow the sidewalk in the location proposed an application for a DSMR (development standard modification request) will be required. The following items must be addressed. DS 2-02.2.1.A.12

Based on redesign or DSMR, the minimum width of any required pedestrian sidewalk is four feet. The construction of the sidewalk must be concrete, brick pavers set in a bed of cement, or any surface equivalent in smoothness, hardness and durability. DS 2-08.4.1.F

Setbacks from PAALs.
A minimum setback distance of five (5) feet for a pedestrian refuge area must be maintained between any enclosed structure and a PAAL. The refuge area may have a roof for shade, provided it contains a sidewalk and pedestrian access which is unobstructed and is set back one (1) foot from the PAAL. The required pedestrian refuge area must be dimensioned. DS 3-05.2.2.B.2

6. If applicable draw the location; label the size and type of any proposed or existing signage. DS 2-02.2.1.A.13

7. Dimension the existing right-of-way for Richey Boulevard. The curb to property line dimension must be labeled. DS 2-02.2.1.A.19

8. If applicable all easements of record must be drawn on the plan. The location, purpose, width and recordation information must be labeled for each easement. DS 2-02.2.1A.20

9. If applicable, freestanding lighting locations and lighting layout and type must be drawn on the plan. DS 2-02.2.1A.25

10. Revise the zoning classification adjacent to the east property line from R-2 to R-3. DS 2-02.2.1.A.28

11. Revise the proposed use to state the use as Multi-family Residential DD "K" and also state what is the existing use of the property. DS 2-02.2.1.A.31

12. Add an LUC code data table that includes the required and actual lot size in square feet and acreage, allowed and proposed building heights, allowed and actual lot coverage (includes the vehicular use area and building areas), allowed and proposed density, and the number of required and provided parking spaces. I acknowledge that some of the items are on the plan but for clarity please have all LUC data under one table. DS 2-02.2.2.A.1-6

RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Revised site plan and landscape plan and requested documents.
10/21/2003 DAVID RIVERA HANDICAP-SITE REVIEW Approved
10/24/2003 JIM EGAN FIRE REVIEW Approved

Final Status

Task End Date Reviewer's Name Type of Review Description
10/28/2003 LISA LESNY OUT TO CUSTOMER Completed