Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Number: T03CM03477
Parcel: 122181000

Review Status: Completed

Review Details: RESIDENTIAL BLDG/WWM

Permit Number - T03CM03477
Review Name: RESIDENTIAL BLDG/WWM
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
08/09/2003 DAVE WITT BUILDING-RESIDENTIAL REVIEW Denied PLAN CHECK COMMENTS - PROJECT #T03CM03477

8/9/03 3607 E. FAIRMOUNT ST.

PLAN REVIEW FOR THE ABOVE REFERENCED STRUCTURE HAS BEEN COMPLETED. THIS LETTER REFLECTS COMMENTS TO BE ADDRESSED. IN ORDER TO FACILITATE A SHORTER BACK CHECK TIME, WE REQUEST THAT YOU PLEASE PROVIDE REVISED PLANS AND CALCULATIONS, HIGHLIGHTING ANY CHANGES, ALONG WITH A WRITTEN RESPONSE TO EACH OF THE NOTED ITEMS INDICATING ACTION TAKEN.

SCOPE OF REVIEW:

THE SCOPE OF THIS PLAN REVIEW COVERS ARCHITECTURAL, PLUMBING, MECHANICAL, MODEL ENERGY AND ELECTRICAL CODES. ALL CODE REFERENCES ARE TO THE 2000 IRC AND STATE PLUMBING CODE. ALL FEATURES WERE CHECKED ONLY TO THE EXTENT ALLOWED BY THE SUBMITTALS PROVIDED. ALL PORTIONS OF THIS PROJECT ARE ASSUMED TO MEET OR WILL MEET OTHER DEPARTMENTAL REQUIREMENTS, CONDITIONS AND CONCERNS BEFORE PERMIT APPROVAL.

GENERAL REQUIREMENTS:

1. ALL CORRECTIONS AND REVISIONS SHALL BE MADE ON THE ORIGINAL TRACINGS AND TWO NEW SETS OF PRINTS OR (1) SEPIA & (1) BLUE LINE SHALL BE RETURNED ALONG WITH ALL REDLINE PRINTS.

2. PEN OR PENCIL CORRECTIONS ON FINAL PRINTS WILL NOT BE ACCEPTABLE. TO AVOID DELAYS ENSURE ALL CORRECTIONS HAVE BEEN MADE, ARE COMPLETE AND HAVE BEEN COORDINATED ON ALL APPLICABLE DETAILS AND NOTES.

SITE PLAN:

1. GENERAL NOTES ; THE '94 U.P.C., WITH THE STATE AMENDMENTS, IS THE PLUMBING CODE TO USE AND THE 2000 ed. I.R.C., AS AMENDED, COVERS STRUCTURAL, ARCHITECTURAL, ELECTRICAL, AND MECHANICAL.

FOUNDATION PLAN:

1. PROVIDE "HOLD DOWNS" IN ACCORDANCE WITH R602.10.6 NEAR THE SOUTH EAST CORNER.

2. PROVIDE LANDINGS PER R312.1.2 .

FLOOR PLANS:

1. THE FIRE PLACE'S HEARTH EXTENSION IS REQUIRED TO EXTEND 16" FOR 8" PAST EACH SIDE OF THE FIREBOX OPENING.

STRUCTURAL PLANS:

1. FRAMING NOTES ; TABLE 23-1-Q IS A U.B.C. TABLE . PLEASE CONSIDER I.R.C.'s TABLE R602.3(1).

2. THE ARABESQUE WINDOW AND THE 2014 XO IN THE TUB AREAS REQUIRE SAFETY GLASS IF THE BOTTOM EDGES ARE LESS THAN 60" ABOVE THE STANDING SURFACE. PLEASE CLARIFY.

ELEVATIONS:

1. NOTE AND DIMENSION THAT THE FIREPLACE CHIMNEY MUST TERMINATE A MINIMUM OF 2' ABOVE ANY
POINT OF ROOF WITHIN 10' MEASURED HORIZONTALLY AND NOT LESS THAN 3' ABOVE THE POINT WHERE
THE CHIMNEY PASSES THROUGH THE ROOF, PER R1001.6

SECTIONS - DETAILS - MISC. NOTES:

1. A and B / 4 ; PLEASE SHOW THE FIREBLOCKS AT THE SOFFITS.

2. PLEASE SPECIFY THE CEILING G.W.B. IS REQUIRED TO BE EITHER ½" SAG RESISTANT OR 5/8" PER TABLE R702.3.5 .

3. 1,2 / 5 ; PLEASE SPECIFY THE JOIST HANGERS.



PLUMBING PLANS:

1. PLUMBING NOTES ; REFERENCE SHOULD BE TO THE '94 U.P.C. WITH STATE AMENDMENTS.

2. THE WATER FIXTURE SCHEDULE SHOULD BE IN ACCORD WITH THE U.P.C.

MECHANICAL PLANS:

1. THE MECHANICAL NOTES SHOULD REFER TO THE I.R.C.

2. THE GAS LINE AND THE COMBUSTION AIR SHOULD REFER TO THE U.P.C.

ELECTRICAL PLANS:

1. NOTE ON PLANS: ELECTRICAL WORK SHALL COMPLY WITH CHAPTERS 33 - 42, 2000 IRC.

2. THE LIGHT FIXTURES OVER THE TUB AND SHOWER ARE REQUIRED TO BE LISTED AS APPROVED FOR USE IN WET AREAS.

3. PLEASE NOTE THAT LIGHT FIXTURES IN CLOTHES CLOSETS SHALL BE INSTALLED IN ACCORDANCE WITH E3903.11.

4. THE RECEPTACLES IN THE BATH ROOMS ARE REQUIRED TO BE ON A 20 AMP DEDICATED CIRCUIT.



IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT YOUR ASSIGNED PLANS EXAMINER:
DAVE WITT @ 791-5550 EXT. 1110


NOTE: AS OF 2-02-01 THE CITY OF TUCSON HAS ADOPTED THE 2000 IRC EXCEPT FOR THE PLUMBING PORTION WHICH IS THE STATE PLUMBING CODE. ( '94 UNIFORM PLUMBING CODE WITH STATE AMENDMENTS ) THE AMENDMENTS ARE AVAILABLE ON THE CITY'S WEB-SITE.
08/14/2003 GERRY KOZIOL WWM REVIEW Approved

Final Status

Task End Date Reviewer's Name Type of Review Description
08/15/2003 DELMA ROBEY OUT TO CUSTOMER Completed