Permit Review Detail
Review Status: Completed
Review Details: RESUBMITTAL
Permit Number - T03CM03375
Review Name: RESUBMITTAL
Review Status: Completed
Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
---|---|---|---|---|---|
02/18/2004 | JIM TATE | ENGINEERING | REVIEW | Denied | Development Plan approval is required. |
02/20/2004 | Robert Sherry | PLUMBING-COMMERCIAL | REVIEW | Denied | 1. Revise floor drains FD-1 and FD-2, floor sink FS-1, and their trap arms as required to comply with Section 1003.3 and Table 10-1, UPC 1994 with AZ State amendments. Note: floor drains FD-1 and FD-2 along with floor sink FS-1 are scheduled with 2" waste connections on Sheet P-2. The trap and the trap arm must be the same size. Section 1003.3 allows the trap and trap arm to be increased by only one pipe size larger than listed in Table 7-3 to avoid losing the self-scouring action of the trap arm. 2. Comment not addressed. Appliances to be directly connected to the water supply system that do not have listed, integral backflow preventers or integral air gaps may require reduced pressure principle backflow preventers. Please submit equipment sheets for determination. Reference Section 603.0, UPC 1994. |
02/20/2004 | ROBERT SHERRY | MECHANICAL-COMMERCIAL | REVIEW | Denied | 1. Comment not completely addressed. Provide signatures for ALL compliance sections of the energy code compliance calculations. Reference Section 302.3, Uniform Administrative Code 1997. 2. Comment not addressed. Provide Listing information of the Type I hoods (1 - 7) to show that the exhaust volumes shown on the drawings are adequate for the intended applications. Reference Section 302.3, Uniform Administrative Code 1997. As stated on the submitted cut sheet for the Model CG3-BDL Hood: "The amount of exhaust volume required is dependent upon the type of cooking equipment and the type and volume of cooking. Refer to the Master Engineering Data Sheet in the Engineering Data section of the Gaylord catalog for the charts on determining exhaust volume, duct sizes, static pressure, water consumption, hot water requirements, and drain sizes." 3. Comment not completely addressed. Coordinate the revised hood information for K-93 (only one hood) with the equipment schedule shown on sheet M-1. Revise the Building Air Balance & Pressurization Data schedule to show only one hood. 4. Documentation not received with submittal. Provide listing information for EF-3. Reference Section 302.3, Uniform Administrative Code 1997. |
03/03/2004 | Martin Haeberle | BUILDING-COMMERCIAL | REVIEW | Approv-Cond | Shop drawings to be reviewed and approved prior to installation |
03/09/2004 | PATRICIA GEHLEN | ZONING | REVIEW | Denied | Zoning 3/9/2004 The building plans may not be reveiwed and approved until copies of the approved development and landscape plans are included in each set of the building plans. |
03/10/2004 | Linda Buczynski | ELECTRICAL-COMMERCIAL | REVIEW | Approved | |
03/10/2004 | GERRY KOZIOL | WWM | REVIEW | Approved |
Final Status
Task End Date | Reviewer's Name | Type of Review | Description |
---|---|---|---|
03/24/2004 | TAMI ACHONG | OUT TO CUSTOMER | Completed |
03/11/2004 | ANGIE SHOFFSTALL | REJECT SHELF | Completed |