Permit Review Detail
Review Status: Completed
Review Details: SITE
Permit Number - T03CM03374
Review Name: SITE
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 07/14/2003 | BLANCA ESPINO | ENGINEERING | REVIEW | Denied | Site Plan 1. Indicate roof slope, downspouts and splash guards. Indicate a detail of downspout, scupper and splash guard. D.S. 2-02.2.1.A.6 2. Indicate existing and future sight visibility triangles of PAAL/Grant Road. D.S. 2-02.2.1.A.10 3. Indicate location, type, size and height of existing and proposed signage, if applicable. D.S. 2-02.2.1.A.13 4. Indicate fully dimensioned loading space, maneuvering area and demonstrate mobility. D.S. 2-02.2.1.A.14 5. Indicate if streets are Public or Private. D.S. 2-02.2.1.A.18 6. Dimensioned right-of-way, including any applicable Major Streets and Routes (MS&R) Plan right-of-way. Grant Road has a Future 60'-1/2 ROW. D.S. 2-02.2.1.A.19 7. Indicate all easements of record (Cross access easement) must be graphically shown on the plan together with recording docket and page reference. D.S. 2-02.2.1.A.20 8. Indicate dimensions from street monument lines to existing and proposed curbs, sidewalks, driveways and utility lines. D.S. 2-02.2.1.A.21 9. Indicate topographic contour intervals used in legend. D.S. 2-02.2.1.A.23 10. Relocate refuse container location and indicate access thereto fully dimensioned. Demonstrate maneuvering mobility. Indicate a detail of refuse enclosure as per D.S. 2-02.2.1.A.32 |
| 07/17/2003 | BLANCA ESPINO | SANITATION | REVIEW | Denied | SEE ENGINEERING FOLDER FOR COMMENTS |
| 07/18/2003 | JIM EGAN | FIRE | REVIEW | Denied | 1. An approved fire apparatus access roadway must be provided and extended to within 150 feet of all portions of exterior walls. An approved turnaround must be provided for dead-end roadways. 2. Indicate location of existing fire hydrants on plan. 3. Submit complete code review checklist. Indicate fire protection rating for west exterior wall. |
| 08/01/2003 | DAN CASTRO | HANDICAP-SITE | REVIEW | Approved | |
| 08/01/2003 | Daniel Castro | ZONING | REVIEW | Denied | COMMENTS: Please attach a response letter with the next submittal, which states how all Zoning Review Section comments regarding the Land Use Code and Development Standards were addressed. CODE SECTION/ DEVELOPMENT STANDARD 1. Note the project address on the site plan. (D.S. 2-02.2.1.A.3) 2. In the location map and title block, the township, range, and section in bold is not correct, please delete. (D.S. 2-02.2.1.A.4) 3. Provide as a note, the number and class type of bicycle parking spaces required and provided. Per LUC 3.3.4, a minimum of four (4) Class II spaces are required based on the 45 vehicle parking spaces provided. (D.S. 2-02.2.1.A.9) (D.S. 2-02.2.2.A.4) 4. Label and dimension the existing and future sight visibility triangles. (D.S. 2-02.2.1.A.10) 5. Dimension the PAAL width located east of the building. (D.S. 2-02.2.1.A.11) 6. Dimension the width of the ingress/egress off of Grant Road. (D.S. 2-02.2.1.A.11) 7. Per Development Standards 3-05.2.2.B.1, a minimum five (5) feet for a pedestrian refuge area must be maintained between the building and the PAAL east of the building. You may provide either a four (4) foot or five (5) foot wide sidewalk within the required five (5) pedestrian refuge area. (D.S. 2-02.2.1.A.12) 8. If applicable, provide a detail of existing and/or proposed free-standing signs or billboard on the site plan. (D.S. 2-02.2.1.A.13) 9. Dimension the wheelstop location on the site plan or vehicle parking space detail. Per D.S. 3-05.2.3.C.2, it is to be located two and one-half (2½) feet from the front of the parking space. (D.S. 2-02.2.1.A.8) 10. Dimension the existing and future right-of-way for Grant Road. Per the Major Streets and Routes (MS&R) Plan, Grant Road is shown as having a future right-of-way of 120 feet. (D.S. 2-02.2.1.A.19) 11. It appears that this site will share access with the adjacent lot to the west. Please provide a copy of the recorded vehicular cross access agreement. (D.S. 2-02.2.1.A.12) 12. If applicable, all existing or proposed easements must be shown on the plan including width, type, and recording docket and page reference. (D.S. 2-02.2.1.A.20) 13. Note the proposed use as follows: "General Merchandise Sales, development designator "31", subject to: LUC Section 3.5.9.2.A." Revise general note three (3) as required. (D.S. 2-02.2.1.A.31) 14. Dimension the future curb location along Grant Road. The face of future curb is located nine (9) feet from the future property line. (D.S. 2-02.2.1.A.21) 15. All requested changes must be made to the site and landscape plans. (D.S. 2-07.2.1.A) If you have any questions about this transmittal, please call Dan Castro, (520) 791-5608. |
| 08/07/2003 | JOE LINVILLE | NPPO | REVIEW | Denied | Submit a Native Plant Preservation Plan or completed application for exception including the documentation listed in the instructions. |
| 08/07/2003 | JOE LINVILLE | LANDSCAPE | REVIEW | Denied | 1) Trees required for the vehicular use area must be evenly distribute. Revise the plans to locate a tree within the parking area along the east property boundary. LUC 3.7.2.3.A.1.a 2) The loading zone must be screened with a 6' high wall along the north property line. LUC Tabel 3.7.2-I 3) The refuse storage area must be located behind a screen six feet in height. LUC Table 3.7.2-I 4) Revise tha plans as requested by other agencies. DS 2-07.2.0 |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 08/08/2003 | MONICA VALDEZ | OUT TO CUSTOMER | Completed |
| 08/08/2003 | ANGIE SHOFFSTALL | REJECT SHELF | Completed |