Permit Number: T03CM03116
Parcel: 134190830

Address:
75 S MONTEGO DR

Review Status: Completed

Review Details: REVISION

Permit Number - T03CM03116
Review Name: REVISION
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
02/14/2005 ANDREW CONNOR LANDSCAPE REVIEW Denied 1. Plants not listed on the Drought Tolerant Plant List may be used as follows per LUC 3.7.2.2.C

· Used in an oasis area and if the plants are grouped in separately programmed irrigation areas according to their water requirements

· Oasis area equal to, but not more than, two and one-half (2.5) percent of the site.

· The oasis is placed on the site near main buildings or assembly areas where pedestrian activities are designed to occur or in an active use area per DS 2-06.3.2.B

· The oasis is located in an area of relatively low evaporation potential from wind and heat per DS 2-06.3.2.B.

· Revise landscapes plan(s) to include plants not listed on the Drought Tolerant Plant List in an oasis area and provide oasis calculations.

2. According to approved site and landscape plan a 6' CMU wall is indicated to south, as-built conditions and Foundation Details Sheet S3.1 includes a wall in excess of 12':

· The maximum height of a wall or fence within a perimeter yard is six (6) feet; however, the wall or fence may be higher than six (6) feet, but no higher than ten (10) feet per LUC 3.2.5.2.H. A variance is needed to wave this requirement.

3. Provide a 30" continuous screen for vehicle use area within landscape border along Montego Dr per LUC 3.7.2-I. Screen is indicated on approved landscape plan.
02/15/2005 LOREN MAKUS ENGINEERING REVIEW Approved
03/04/2005 PETER MCLAUGHLIN ZONING REVIEW Denied Provide a copy of LDO approval letter. It is unclear if the LDO was approved for the building setback to the south property line (required 1-1/2 x H. to adjacent R-1 zoning) or for the wall height (also required 1-1/2 x H. to adjacent R-2 zoning, or both. At 5 feet from the west property line, the wall (1-1/2 x 12 feet high = 18 foot required setback) does not meet the required perimeter yard setback and an LDO is required for the wall height.
LUC 3.2.5.2.I
LUC 3.2.6.4

Final Status

Task End Date Reviewer's Name Type of Review Description
03/23/2005 BETH GRANT OUT TO CUSTOMER Completed
03/23/2005 ANGIE SHOFFSTALL REJECT SHELF Completed