Permit Review Detail
Review Status: Completed
Review Details: RESUBMITTAL - SITE
Permit Number - T03CM03116
Review Name: RESUBMITTAL - SITE
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 09/29/2003 | PETER MCLAUGHLIN | ZONING | REVIEW | Denied | SITE PLAN TRANSMITTAL TO: Hudson Design/ Valerie Hudson 439 N. 6th Avenue Tucson, AZ 85705 (520) 624-5115 FROM: Peter McLaughlin Development Services Dept. FOR: PATRICIA GEHLEN Principal Planner Development Services Dept. PROJECT: T03CM03116 Handi-Dogs, Inc. 75 S. Montego Drive Site Plan Review (2nd review) TRANSMITTAL: September 29, 2003 COMMENTS: Upon completion of the following revisions/additions, an over the counter review may be arranged to obtain stamped approval by the zoning review section without resubmitting the site plan. The following items must be revised on or added to the site plan: 1. Correct the abbreviation "Blk" in the legal description to read "Bk" for Book. DS 2-02.1.A.2 2. The Lot Development Option (LDO) must be approved prior to site plan approval. If the LDO is approved, please list as a general note the following: case number; date of approval, and conditions imposed if any. DS 2-05.2.2.B.6 3. The parking calculations read "provided: 19 spaces", but only 18 spaces (14 standard and 4 handicap) are depicted on the drawing. Please revise. DS 2-02.2.2.A.4 If you have any questions about this transmittal, please call Peter McLaughlin, (520) 791-5608. |
| 09/29/2003 | Peter McLaughlin | HANDICAP-SITE | REVIEW | Approved | |
| 09/29/2003 | LOREN MAKUS | ENGINEERING | REVIEW | Approv-Cond | A grading permit is required. The grading plan submitted with the grading permit application must show steel pipes along the sides of the trash enclosure as well as at the back. |
| 10/02/2003 | JOE LINVILLE | LANDSCAPE | REVIEW | Denied | 1) A street landscape border is required along the entire Montego Street frontage. The border must be a minimum of ten feet wide at all points. LUC 3.7.2.4.A The central landscape buffer along Montego Drive measures only 7'6' within the property limits. 2) Provide verification of City Engineer approval, in writing, regarding placement of landscaping within the public right of way. The landscape border as drawn occupies a portion of the public right of way. 3) Clarify what is measured in the sizes listed in the Native Plant Inventory. |
| 10/02/2003 | JOE LINVILLE | NPPO | REVIEW | Approved |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 10/06/2003 | TAMI ACHONG | OUT TO CUSTOMER | Completed |
| 10/06/2003 | CINDY AGUILAR | REJECT SHELF | Completed |