Permit Number: T03CM03070
Parcel: 104090660

Review Status: Completed

Review Details: RESIDENTIAL BLDG/WWM

Permit Number - T03CM03070
Review Name: RESIDENTIAL BLDG/WWM
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
08/28/2003 MELISSA POULIN WWM REVIEW Approved
09/05/2003 Terry Stevens BUILDING-RESIDENTIAL REVIEW Denied PLAN CHECK COMMENTS - PROJECT #T03CM03070
09/06/03
PLAN REVIEW FOR THE ABOVE REFERENCED STRUCTURE HAS BEEN COMPLETED. THIS LETTER REFLECTS COMMENTS TO BE ADDRESSED. IN ORDER TO FACILITATE A SHORTER BACK CHECK TIME, WE REQUEST THAT YOU PLEASE PROVIDE REVISED PLANS AND CALCULATIONS, HIGHLIGHTING ANY CHANGES, ALONG WITH A WRITTEN RESPONSE TO EACH OF THE NOTED ITEMS INDICATING ACTION TAKEN.

GENERAL REQUIREMENTS:

1. ALL CORRECTIONS AND REVISIONS SHALL BE MADE ON THE ORIGINAL TRACINGS AND TWO NEW SETS OF PRINTS OR (1) SEPIA & (1) BLUE LINE SHALL BE RETURNED ALONG WITH ALL REDLINE PRINTS.

2. PEN OR PENCIL CORRECTIONS ON FINAL PRINTS WILL NOT BE ACCEPTABLE. TO AVOID DELAYS ENSURE ALL CORRECTIONS HAVE BEEN MADE, ARE COMPLETE AND HAVE BEEN COORDINATED ON ALL APPLICABLE DETAILS AND NOTES.

SITE PLAN:

1. IF GARAGE IS UNDER SEPARATE PERMIT, CLEARLY INDICATE SO ON SITE PLAN.

FOUNDATION PLANS:

1. INDICATE MIN. 6" CLEARANCE FROM GRADE TO BOTTOM OF SILL PLATE-----DETAIL 1/S-1.

2. LOCATE AND DETAIL ALL FOOTINGS FOR THE FOLLOWING:
- OPTIONAL FIREPLACE

FLOOR PLANS:

1. IF SHOWER IS 12" BELOW SLAB, STEPS WILL BE REQUIRED. MAX. RISE IS 73/4".

2. DETAIL AND SPECIFY STAIR WIDTH (MINIMUM 36"), RISE AND RUN (MINIMUM 10" TREAD DEPTH AND 7 ¾"
MAXIMUM RISER HEIGHT PER R314), LANDING WIDTH (PER R312), HANDRAIL HEIGHTS (PER R315),
GUARDRAIL HEIGHT (PER R316) AND INTERMEDIATE RAIL SPACING (PER R316).

GUARD RAIL INFO. MISSING AT SECOND FLOOR
SEE SEC. R314.4 AND R314.6 FOR MIN. SIZE OF TREADS AT STAIRS

3. FIREPLACES: - INDICATE HEARTH SIZE AND MATERIALS, PER R1003.10 OR R1004.2

STRUCTURAL PLANS:

1. DETAIL 3/A-4 DOES NOT REFLECT CONDITIONS OF I-JOISTS TO BEAM/ TRUSS TO BEAM.

2. PROVIDE DETAIL OF ROOF CONNECTION AT NEW BEAM AT EXISTING BUILDING [OVER KITCHEN AREA]

3. NOTE AND DETAIL TIE STRAPS FRAMING ANCHORS AND JOIST HANGERS BY TYPE, SIZE AND REQUIRED
ATTACHMENT TO FRAMING MEMBERS.

4. AS INDICATED STRUCTURE DOES NOT COMPLY WITH THE BRACED WALL DESIGN OR THE ALTERNATE BRACED WALL DESIGN REQUIREMENTS -- SEE BELOW

PROVIDE BRACING DETAILS AND NOTES FOR EXTERIOR FRAME WALLS AND MAIN CROSS-STUD PARTITIONS,
OR USE FULLY BRACED, PER R602.10.3. A MINIMUM PANEL WIDTH OF 48" IS REQUIRED TO EFFECTIVELY
BRACE THE PARTITION. SEE TABLE R602.10.3, CATEGORY "C". IF BRACING DOES NOT COMPLY, PROVIDE A
LATERAL ANALYSIS OR ALTERNATE DESIGN TO BE REVIEWED BY THE PLANS EXAMINER. WIND FORCES
FOR SINGLE STORY RESIDENCES SHALL USE 90 MPH, EXPOSURE "B". TWO STORY RESIDENCES OR AREAS OF
HIGHER WIND SHALL USE EXPOSURE "C".

5. PROVIDE STAIRWAY CONNECTION DETAILS AND STRINGER SIZES.



PLUMBING PLANS:

1. CLARIFY GAS METER LOCATION. SITE PLAN DIFFERS FROM PLUMBING PLAN.

2. GAS: PROVIDE THE LENGTH OF LINE TO EACH APPLIANCE,

ELECTRICAL PLANS:

1. NOTE THE LOCATION, TYPE AND AMPERAGE OF THE PANEL. NOTE THE GROUNDING AND BONDING METHOD.
IS THIS A NEW SERVICE OR A SUBPANEL FROM EXISTING SERVICE? CLARIFY

2. ISLAND OR PENINSULA COUNTER TOPS SHALL HAVE AT LEAST ONE RECEPTACLE OUTLET AT EACH
COUNTER SPACE WITH A LONG DIMENSION OF 24" OR GREATER, AND A SHORT DIMENSION OF 12" OR
GREATER, PER E3801.4.2 AND E3802.4.3.

3. ALL RECEPTACLE OUTLETS IN BATHROOMS, KITCHENS, UNFINISHED BASEMENTS, GARAGES OR CARPORTS,
AT GRADE LEVEL AND WITHIN 6' OF A WET BAR OR KITCHEN SINK SHALL HAVE GROUND FAULT CIRCUIT
INTERRUPTING PROTECTION. NOTE ON THE DRAWINGS AT EACH OUTLET REQUIRING SUCH PROTECTION,
PER E3802.

4. REMOVE GARAGE ELEC. IF PERMITTED SEPARATELY.

5. SHOW LOCATIONS OF SMOKE DETECTORS PER R317. NOTE THAT ALL SMOKE DETECTORS MUST BE
INTERCONNECTED WITH A POWER SOURCE FROM THE BUILDING WIRING, AND SHALL BE EQUIPPED WITH
BATTERY BACKUP.

REQUIRED AT THE ACCESS TO ALL BEDROOMS AND AT THE TOP AND BOTTOM OF A STAIRCASE.

IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT YOUR ASSIGNED PLANS EXAMINER:
TERRY STEVENS @ 791-5550 EXT. 1112

Final Status

Task End Date Reviewer's Name Type of Review Description
09/08/2003 CINDY AGUILAR OUT TO CUSTOMER Completed
09/08/2003 CINDY AGUILAR REJECT SHELF Completed