Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Number: T03CM02616
Parcel: 10511061R

Review Status: Completed

Review Details: 3RD PARTY REVIEW-REVISION/OTHER

Permit Number - T03CM02616
Review Name: 3RD PARTY REVIEW-REVISION/OTHER
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
06/12/2003 STANTEC 3RD PARTY REVIEW-COMMERCIAL REVIEW Denied GENERAL:

q Sheet SP1 in the bound bond copy needs to be reprinted. Only half of the sheet is present do to the printer improperly feeding the page. Please provide a replacement for this sheet.

ARCHITECTURAL:

q Indicate the type of construction in the code information on Sheet A101. Currently the code study indicates that the construction type is "II-N" which is incorrect. Type II-N is the same as type II-B for the IBC.
q Sheet A101: The space is required to have at least two means of egress. The plans do not clearly show the second means of egress, including the path to an 'exit' as well as a hardware description for any doors in the exit access.


q Sheet A101: Plans shall clearly detail compliance with IBC Section 402.11, items 1 through 3.

STRUCTURAL:

q There are no structural comments to be addressed.

MECHANICAL:

q There are no mechanical comments to be addressed.

PLUMBING:

q There are no plumbing comments to be addressed.

ELECTRICAL:

q The plans shall clearly show exit signs for the two required means of egress in compliance with IBC Section 1003.2.9, including locations and emergency power.
q The plans shall clearly show emergency egress illumination for the sales room and for the two required means of egress in compliance with IBC Sections 1003.2.11.2 and 1002.2.11.3.

-End of Review-

Final Status

Task End Date Reviewer's Name Type of Review Description
06/12/2003 ELAINE ROSE OUT TO CUSTOMER Completed