Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

PRO is currently experiencing an outage. Some documents and records may not be available on PRO momentarily. We apologize for the inconvenience and are working to restore full access.

Permit Number: T03CM02594
Parcel: 116272140

Review Status: Completed

Review Details: RESIDENTIAL BLDG/ZONING/ENGINE/WWM

Permit Number - T03CM02594
Review Name: RESIDENTIAL BLDG/ZONING/ENGINE/WWM
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
06/04/2003 GERRY KOZIOL WWM REVIEW Denied Needs Wastewater design review of rejector system - Bob Buecher 617-8206
06/04/2003 JIM EGAN FIRE REVIEW Approved
06/16/2003 LOREN MAKUS ENGINEERING REVIEW Approved
06/26/2003 JOE LINVILLE NPPO REVIEW Denied Native Plant Preservation, and revegetation is required for this project. The plans for the revised building envelope approved April 7, 2003 requires a minimum of 11 replacement trees; more if additional trees are removed and preservation or relocation of all saguaros. Provide plans that demonstrate compliance with these requirements.

Add a note to the site and grading plans that states "An inspection of the grading limits by the City Landscape Inspector is required prior to any site disturbance or grading."
06/30/2003 PATRICIA GEHLEN ZONING REVIEW Approved
07/02/2003 DAVE WITT BUILDING-RESIDENTIAL REVIEW Denied PLAN CHECK COMMENTS - PROJECT #T02CM02594

7/8/03 3611 W. EAGLES VIEW PL.

PLAN REVIEW FOR THE ABOVE REFERENCED STRUCTURE HAS BEEN COMPLETED. THIS LETTER REFLECTS COMMENTS TO BE ADDRESSED. IN ORDER TO FACILITATE A SHORTER BACK CHECK TIME, WE REQUEST THAT YOU PLEASE PROVIDE REVISED PLANS AND CALCULATIONS, HIGHLIGHTING ANY CHANGES, ALONG WITH A WRITTEN RESPONSE TO EACH OF THE NOTED ITEMS INDICATING ACTION TAKEN.

SCOPE OF REVIEW:

THE SCOPE OF THIS PLAN REVIEW COVERS ARCHITECTURAL, PLUMBING, MECHANICAL, MODEL ENERGY AND ELECTRICAL CODES. ALL CODE REFERENCES ARE TO THE 2000 IRC AND STATE PLUMBING CODE. ALL FEATURES WERE CHECKED ONLY TO THE EXTENT ALLOWED BY THE SUBMITTALS PROVIDED. ALL PORTIONS OF THIS PROJECT ARE ASSUMED TO MEET OR WILL MEET OTHER DEPARTMENTAL REQUIREMENTS, CONDITIONS AND CONCERNS BEFORE PERMIT APPROVAL.

GENERAL REQUIREMENTS:

1. ALL PLANS SHALL BE LEGIBLE AND A SCALE NO SMALLER THAN ¼ INCH = 1-FOOT SHALL BE USED
FOR ALL FLOOR PLANS, FRAMING PLANS AND ELEVATIONS. DETAILS &CROSS SECTIONS AT A MINIMUM 3/8 INCH = 1-FOOT SCALE.

2. ALL CORRECTIONS AND REVISIONS SHALL BE MADE ON THE ORIGINAL TRACINGS AND TWO NEW SETS OF PRINTS OR (1) SEPIA & (1) BLUE LINE SHALL BE RETURNED ALONG WITH ALL REDLINE PRINTS.

3. PEN OR PENCIL CORRECTIONS ON FINAL PRINTS WILL NOT BE ACCEPTABLE. TO AVOID DELAYS ENSURE ALL CORRECTIONS HAVE BEEN MADE, ARE COMPLETE AND HAVE BEEN COORDINATED ON ALL APPLICABLE DETAILS AND NOTES.

4. ALL ENGINEERS AND ARCHITECTS INVOLVED IN THE DESIGN OF THE STRUCTURE ARE TO SEAL THE
RELATED SHEETS OF PLANS, DETAILS AND CALCULATIONS. THIS IS IN ACCORDANCE WITH THE RULES OF
THE STATE BOARD OF TECHNICAL REGISTRATION.





FLOOR PLANS:

1. PROVIDE HANDRAILS FOR STEPS WITH 2 OR MORE RISERS. PLEASE PROVIDE DETAIL.

2. WILL THE GREENHOUSE BE A DEFERRED SUBMITTAL?

STRUCTURAL PLANS:

1. ROOF FRAMING / S-2 ; HOW WILL THE RAFTER/WALL CONNECTION BE MADE OVER THE DINING ROOM BAY WINDOW? BEAM, LINTEL,….WILL THE RAFTERS SPAN THE INCREASED SPAN ?

2. FRAME CONSTRUCTION NOTE #5 / S-0 ; AN 8" ANCHOR BOLT WON'T PROVIDE 7" EMBEDMENT UNDER A 2X PLATE.

3. FRAME CONSTRUCTION NOTE #5 / S-0 ; PLEASE PROVIDE DETAIL 213 .

PLUMBING PLANS:

1. EJECTOR SUMP / MP1.1 ; PLEASE JUSTIFY THE 2" VENT IN ACCORDANCE WITH U.P.C. 710.10

2. PLEASE SPECIFY THE SIZE AND LOCATION OF THE COMBUSTION AND RELIEF AIRS.

3.RESIDENTIAL FIXTURE CONNECTION SCHEDULE / P1.1 ; THE SCHEDULE SHOULD BE IN ACCORD WITH THE '94 U.P.C. NOT THE I.R.C. HOW DOES THIS AFFECT THE DISTRIBUTION SIZES FOR THIS HOUSE ?


ELECTRICAL PLANS:

1. RECEPTACLES ARE REQUIRED ON WALLS 2' WIDE AND WIDER. IS A RECEPTACLE REQUIRED IN THE NORTH EAST CORNER OF THE GREAT ROOM ?






IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT YOUR ASSIGNED PLANS EXAMINER:
DAVE WITT @ 791-5550 EXT. 1110


NOTE: AS OF 2-02-01 THE CITY OF TUCSON HAS ADOPTED THE 2000 IRC EXCEPT FOR THE PLUMBING PORTION WHICH IS THE STATE PLUMBING CODE. ALL MODEL PLANS SHALL BE REFERENCE TO THE PREVIOUSLY MENTIONED CODES.

Final Status

Task End Date Reviewer's Name Type of Review Description
07/21/2003 LISA LESNY OUT TO CUSTOMER Completed