Permit Number: T03CM02588
Parcel: 141110300

Review Status: Completed

Review Details: COMMERCIAL TI

Permit Number - T03CM02588
Review Name: COMMERCIAL TI
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
05/28/2003 JIM EGAN FIRE REVIEW Approved
05/28/2003 PATRICIA GEHLEN ZONING REVIEW Approved
06/02/2003 DOUG LAAKSO BUILDING-COMMERCIAL REVIEW Denied .. T03CM02588 .. 8500 E OLD VAIL ROAD .. 6/3/03 .. DGL .. S1. PROVIDE COMPLETED COMMERCIAL PLAN SUBMITTAL CHECKLIST BY ARCHITECT OR ENGINEER OF RECORD. ....................................................................... . S2. PROVIDE COMPLETED ' CODE REVIEW CHECKLIST ' BY ARCHITECT OR ENGINEER OF RECORD. ............... ..... S3. PROVIDE 2nd SITE PLAN. ........................... .......... ... S4. REVISE SITE PLAN TO CONFORM WITH INTERNATIONAL BUILDING CODE. .................. ............ ... S5. PROVIDE COPY OF PLANS FOR EX. BUILDING AND SITE , FOR REVIEW. ....................... .................... ... ....... S6. ADDRESS ACCESSIBILITY PER IBC CHAPTER 11 AND 34. ...................................... ................................ .......... S7. PROVIDE FLOOR PLAN SHOWING IBC : .. OCCUPANCY OF STRUCTURE PER IBC CHAP 3, SPECIAL OCCUPANCIES ETC CHAP 4, ALLOWABLE AREA CALC CHAP 5, CONSTRUCTION TYPE CHAP 6, FIRE RATED WALLS CHAP 7 , EXITING PER CHAP 10. ................. ....... S8. PROVIDE ADEQUATE FINISH GRADE ELEVATIONS ON SITE PLAN TO SHOW CONFORMANCE WITH IBC CHAP 10, 11 AND 34. ........................... ................... ............ ....... . S9. PROVIDE SPEC ON SHADE CLOTH AND ATTACHMENT TO STRUCTURE ( DETAILS ) AND NON-COMBUSTIBLE OR FLAME-RESISTANT, PER IBC SEC 3102 AND 3105. .... .... .. S10. SHOW PROTECTION , ON PLANS, FOR STRUCTURAL MEMBERS PER IBC SEC 3105. ....................... ............ ..... S11. PROVIDE FLOOR PLANS FOR EXISTING BUILDING AND NEW STRUCTURE SHOWING OCCUPANCY OF ALL ROOMS AND SPACES, ON DRAWINGS. ........................ .... S12. PROVIDE SPECIFICATIONS ON CLEVIS AND RODS, REF DET 4, VERIFY WELDING COMPATIBILITY. .... .... ..... . S13. SPECIAL INSPECTION REQUIRED : FIELD WELDING , SHOP WELDING, AND INSTALLATIONS OF RODS. .... ...... S14. PROVIDE PREMISES IDENTIFICATION PER IBC SEC 501.2, SHOW LOCATION ON DRAWINGS. ................ .... ... S15. PROVIDE ADDRESSING ON SITE AND STRUCTURE/S PER PIMA COUNTY ADDRESSING ORDINANCE, SEE ATTACHMENT, SHOW ON DRAWINGS. .............. ........... ... S16. SEPARATE PERMIT REQUIRED FOR SIGNS.
06/10/2003 ROBERT SHERRY PLUMBING-COMMERCIAL REVIEW Passed
06/10/2003 ROBERT SHERRY WATER REVIEW Passed
06/10/2003 ROBERT SHERRY MECHANICAL-COMMERCIAL REVIEW Passed
06/23/2003 LOREN MAKUS ENGINEERING REVIEW Approved
06/24/2003 GERRY KOZIOL WWM REVIEW Passed
06/26/2003 LINDA BUCZYNSKI ELECTRICAL-COMMERCIAL REVIEW Passed

Final Status

Task End Date Reviewer's Name Type of Review Description
09/04/2003 MONICA VALDEZ OUT TO CUSTOMER Completed
06/27/2003 ANGIE SHOFFSTALL REJECT SHELF Completed