Permit Number: T03CM02487
Parcel: 12709001E

Review Status: Completed

Review Details: 3RD PARTY REVIEW-COMMERCIAL TI

Permit Number - T03CM02487
Review Name: 3RD PARTY REVIEW-COMMERCIAL TI
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
06/03/2003 STANTEC 3RD PARTY REVIEW-COMMERCIAL REVIEW Denied GENERAL:

q There are no general comments to be addressed.

ARCHITECTURAL:

q Are there any accessible restrooms in this facility? The restrooms shown do not appear to be accessible. If there are currently no accessible restrooms, then they will need to be provided.

q Because the building is being altered, those areas of primary function (i.e. the exam rooms) need to be made accessible [2000 IBC Sec. 3408.6]. The door swings to these rooms do not allow for access [ANSI A117.1-1998 Sec. 404.2.4.1]. The cost of these modifications can be limited to 20% of the cost of the alteration [2000 IBC Sec. 3408.6 Exception 1].

q There are two doors connecting Corridor 1072 to Corridors 1067 and 1073. These doors are part of an accessible rout but are not accessible [ANSI A117.1-1998 Sec. 404.2.4.1]. As part of an accessible rout to an area of primary function, these doors need to be made accessible [2000 IBC Sec. 3408.6].

STRUCTURAL:

q There are no structural comments to be addressed.

MECHANICAL:

q There are no mechanical comments to be addressed.

PLUMBING:

q There are no plumbing comments to be addressed.

ELECTRICAL:

q There are no electrical comments to be addressed.

-End of Review-
06/04/2003 EROSE1 WWM REVIEW Needs Review
06/04/2003 EROSE1 FIRE REVIEW Needs Review
06/04/2003 EROSE1 WATER REVIEW Needs Review

Final Status

Task End Date Reviewer's Name Type of Review Description
06/04/2003 ELAINE ROSE OUT TO CUSTOMER Completed