Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Number: T03CM02451
Parcel: 128102930

Review Status: Completed

Review Details: 3RD PARTY REVIEW-COMMERCIAL

Permit Number - T03CM02451
Review Name: 3RD PARTY REVIEW-COMMERCIAL
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
07/07/2003 EROSE1 WWM REVIEW Needs Review
07/07/2003 EROSE1 ENGINEERING REVIEW Needs Review
07/07/2003 WILDAN 3RD PARTY REVIEW-COMMERCIAL REVIEW Denied GENERAL COMMENTS:

1. This project has been reviewed for conformance with the 2000 IBC, 1997 UAC, 2000 IMC, 1998 IECC, 1999 NEC codes with local modifications, and the 1994 UPC with State of Arizona amendments. Any revisions to this plan will require an additional review and approval by Willdan.

ARCHITECTURAL COMMENTS:

1. The accessible elevator must be able to run on emergency power. Reference IBC Sections 1003.2.13.1.1 and 1003.2.13.3.

2. Specify interior finish class or other requirements for walls, ceilings, floors, and trim. Reference IBC Sections 803, 804, and 805.

3. Blown-in insulation must be noted to have qualifying fire tests for approval as fire-blocking material. Reference IBC Section 716.2.1.


STRUCTURAL COMMENTS:

1. We received two copies of "Additional Structural Calculation" dated June 16, 2003, but we did not receive the required two copies of the revised structural calculations. Back-check of structural is on hold until receipt of all required structural documents.

2. Structural responses such as, "See revised structural drawings and calculations" are rather vague. Response to review comments should contain more text detail and bolstered with notations having specificity, such as detail number, calculation page, and structural design methodology, etc.


PLUMBING COMMENTS:

1. Corrosion-resistant drip pans under hot water tanks on the second floor. Reference UPC 510.7.


ELECTRICAL COMMENTS:

1. Two copies of catalog cuts of outdoor lighting fixtures and lamps.
07/07/2003 ELAINE ROSE ZONING REVIEW Needs Review
07/07/2003 EROSE1 WATER REVIEW Needs Review
07/07/2003 EROSE1 FIRE REVIEW Needs Review

Final Status

Task End Date Reviewer's Name Type of Review Description
07/03/2003 ELAINE ROSE OUT TO CUSTOMER Completed