Permit Review Detail
Review Status: Completed
Review Details: OTHER
Permit Number - T03CM02400
Review Name: OTHER
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 05/22/2003 | GERRY KOZIOL | WWM | REVIEW | Approved | |
| 06/04/2003 | PAUL MACHADO | ENGINEERING | REVIEW | Approved | |
| 06/11/2003 | TERRY STEVENS | BUILDING-RESIDENTIAL | REVIEW | Denied | PLAN CHECK COMMENTS - PROJECT #T03CM02400 06/12/03 PLAN REVIEW FOR THE ABOVE REFERENCED STRUCTURE HAS BEEN COMPLETED. THIS LETTER REFLECTS COMMENTS TO BE ADDRESSED. IN ORDER TO FACILITATE A SHORTER BACK CHECK TIME, WE REQUEST THAT YOU PLEASE PROVIDE REVISED PLANS AND CALCULATIONS, HIGHLIGHTING ANY CHANGES, ALONG WITH A WRITTEN RESPONSE TO EACH OF THE NOTED ITEMS INDICATING ACTION TAKEN. GENERAL REQUIREMENTS: 1. ALL CORRECTIONS AND REVISIONS SHALL BE MADE ON THE ORIGINAL TRACINGS AND TWO NEW SETS OF PRINTS OR (1) SEPIA & (1) BLUE LINE SHALL BE RETURNED ALONG WITH ALL REDLINE PRINTS. 2. PEN OR PENCIL CORRECTIONS ON FINAL PRINTS WILL NOT BE ACCEPTABLE. TO AVOID DELAYS ENSURE ALL CORRECTIONS HAVE BEEN MADE, ARE COMPLETE AND HAVE BEEN COORDINATED ON ALL APPLICABLE DETAILS AND NOTES. FOUNDATION PLANS: 1. DIMENSION REQUIRED DISTANCE FROM THE NATURAL GRADE TO BOTTOM OF SILL PLATE AND POSTS. MIN. DISTANCE IS 6". 2. ALL SLABS AND PADS, INCLUDING LANDINGS AT ALL DOORS, SHALL BE SHOWN AND THEIR THICKNESS SPECIFIED. INDICATE THE SLOPE FOR EXTERIOR SLABS, PER R312. 3. ALL FOUNDATION HOLD-DOWNS AND ANCHOR BOLT SPACING FOR BRACED WALL PANELS SHALL BE SPECIFIED AND LOCATED.-------HOLD DOWN IS REQUIRED AT EACH END OF ALL PANELS LESS THAN FOUR FOOT IN LENGTH-------PAHD42 HOLD DOWNS CANNOT BE USED WITH IN 8" OF A CORNER AND ACHIEVE 1800# OF UPLIFT------AN HPAHD22 MEETS THE REQUIREMENTS FLOOR PLANS: 1. LOCATE AND IDENTIFY BRACED WALL TYPES, LENGTHS, AND LOCATIONS. STRUCTURAL PLANS: 1. COMPLETELY DETAIL ALL CONNECTIONS AND CROSS-REFERENCE TO THE FOUNDATION AND FRAMING PLANS: - LEDGERS TO FRAME, FRAME TO LEDGERS--------MISSING AT PORCHES - JOIST TO LEDGER-------MISSING AT PORCHES - HANGER TYPES--------MISSING AT PORCHES - HOLD DOWN LOCATIONS AND TYPE 2. NOTE AND DETAIL TIE STRAPS FRAMING ANCHORS AND JOIST HANGERS BY TYPE, SIZE AND REQUIRED ATTACHMENT TO FRAMING MEMBERS. 3. NOTE: PLANS AS SUBMITTED DO NOT MEET THE ALTERNATE BRACED WALL DESIGN. PANELS ARE REQUIRED NO FURTHER APART THAN 25'.-------------SEE BELOW PROVIDE BRACING DETAILS AND NOTES FOR EXTERIOR FRAME WALLS AND MAIN CROSS-STUD PARTITIONS, OR USE FULLY BRACED, PER R602.10.3. A MINIMUM PANEL WIDTH OF 48" IS REQUIRED TO EFFECTIVELY BRACE THE PARTITION. SEE TABLE R602.10.3, CATEGORY "C". IF BRACING DOES NOT COMPLY, PROVIDE A LATERAL ANALYSIS OR ALTERNATE DESIGN TO BE REVIEWED BY THE PLANS EXAMINER. WIND FORCES FOR SINGLE STORY RESIDENCES SHALL USE 90 MPH, EXPOSURE "B". TWO STORY RESIDENCES OR AREAS OF HIGHER WIND SHALL USE EXPOSURE "C". ELEVATIONS: 1. SIZE ALL ROOF DRAINS OR SCUPPERS ON FLAT-ROOFED AREAS PER R903.4. 2. NOTE AND DIMENSION THAT THE FIREPLACE CHIMNEY MUST TERMINATE A MINIMUM OF 2' ABOVE ANY POINT OF ROOF WITHIN 10' MEASURED HORIZONTALLY AND NOT LESS THAN 3' ABOVE THE POINT WHERE THE CHIMNEY PASSES THROUGH THE ROOF, PER R1001.6 SECTIONS - DETAILS - MISC. NOTES: 1. WOOD SILL PLATES SHALL BE FOUNDATION GRADE REDWOOD OR PRESSURE-TREATED WOOD PER R324. PLUMBING PLANS: 1. THE CITY OF TUCSON HAS NOT ADOPTED THE PLUMBING SECTION OF THE IRC 2OOO. THE CURRENT CODE BEING USED IS THE 1994 UPC WITH THE STATE AMENDMENTS. ALL PLANS MUST MEET AND REFERENCE THIS CODE. 2. WASTE LINE PLAN AS INDICATED DOES NOT MEET CODE REQUIREMENTS. LOCATION OF VENTS, SIZE OF HORIZ. WASTE LINES, CLEANOUT LOCATIONS, ETC. ARE WRONG. 3. GAS: 3/8" LINE TO FIREPLACE INADEQUATE 4. WATER LINE: PROVIDE TOTAL FIXTURE DEMAND & MAXIMUM DEVELOPED LENGTH---AS PER 1994 UPC ½" COLD WATER LINE TO MASTER BATH INADEQUATE SIZE OF WATER LINE TO HOUSE INADEQUATE MECHANICAL PLANS: 1. NOTE ON PLANS: MECHANICAL SHALL COMPLY WITH CHAPTERS 12 -16 AND18- 24 2000 IRC. CITY HAS NOT ADOPTED CHAPTER 17 2. GAS APPLIANCES SHALL COMPLY WITH 1994 UPC WITH STATE AMENDMENTS FOR COMBUSTION AIR REQUIREMENTS. DETAIL HOW.----------MISSING FOR GARAGE AREA AND INADEQUATE FOR 2ND MECH. ROOM 3. INDICATE SIZE OF ALL SUPPLY AND RETURN AIR DUCTS. ELECTRICAL PLANS: 1. NOTE THAT ALL SMOKE DETECTORS MUST BE INTERCONNECTED WITH A POWER SOURCE FROM THE BUILDING WIRING, AND SHALL BE EQUIPPED WITH BATTERY BACKUP. IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT YOUR ASSIGNED PLANS EXAMINER: TERRY STEVENS @ 791-5550 EXT. 112 |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 06/23/2003 | MONICA VALDEZ | OUT TO CUSTOMER | Completed |
| 06/20/2003 | ANGIE SHOFFSTALL | REJECT SHELF | Completed |