Permit Number: T03CM02166
Parcel: 122184310

Review Status: Completed

Review Details: RESUBMITTAL - SITE

Permit Number - T03CM02166
Review Name: RESUBMITTAL - SITE
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
07/24/2003 James Tate ENGINEERING REVIEW Denied DATE: July 24, 2003
ACTIVITY NUMBER: T03CM02166
PROJECT NAME: Richey-Cody Development
PROJECT ADDRESS: 3565 E. Speedway Blvd.
PROJECT REVIEWER: James C. Tate, P.E.

Resubmittal Required: Site Plan

The following items must be revised or added to the site plan. Please include a response letter with the next submittal that states how all comments have been addressed.

1. Development Services Engineering staff will not accept landscaping in the public right-of-way. Written approval from Andy Dinauer (City Engineer for Public Improvements) is required. Provide.

2. Sidewalks must be flood free for up to the ten year event. The building roof overhangs to the north and roof drainage is being allowed to flood the sidewalk (building to Cody Street). Correct.
08/19/2003 DAN CASTRO HANDICAP-SITE REVIEW Approved
08/19/2003 Daniel Castro ZONING REVIEW Denied COMMENTS: Please attach a response letter with the next
submittal, which states how all Zoning Review Section comments regarding the Land Use Code and Development Standards were addressed.
CODE SECTION/ DEVELOPMENT STANDARD

1. A copy of the covenant and tax combination form were not found in the resubmittal package.
Previous comment: Per Pima County Assessors Records, the site is comprised of two separate parcels which must be combined by providing a copy of the recorded City of Tucson lot combination covenant and a copy of the approved Pima County Assessors Tax Combination form. Attached is a copy of the City of Tucson lot combination covenant. Contact the Pima County Assessors office to obtain the Tax Combination form. (D.S. 2-02.2.1.A.2)

2. Dimension the existing right-of-way for Richey Blvd. and Cody Avenue on sheet D-1. (D.S. 2-02.2.1.A.19

3. All requested changes must be made to the site and landscape plans. (D.S. 2-07.2.1.A)

If you have any questions about this transmittal, please call Dan Castro, (520) 791-5608.