Permit Review Detail
Review Status: Completed
Review Details: OTHER
Permit Number - T03CM02035
Review Name: OTHER
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 04/30/2003 | GERRY KOZIOL | WWM | REVIEW | Denied | Needs WasteWater review for credit. |
| 05/22/2003 | DAVE WITT | BUILDING-RESIDENTIAL | REVIEW | Denied | PLAN CHECK COMMENTS - PROJECT #T02CM02035 5/23/03 2103 E. 5TH PLAN REVIEW FOR THE ABOVE REFERENCED STRUCTURE HAS BEEN COMPLETED. THIS LETTER REFLECTS COMMENTS TO BE ADDRESSED. IN ORDER TO FACILITATE A SHORTER BACK CHECK TIME, WE REQUEST THAT YOU PLEASE PROVIDE REVISED PLANS AND CALCULATIONS, HIGHLIGHTING ANY CHANGES, ALONG WITH A WRITTEN RESPONSE TO EACH OF THE NOTED ITEMS INDICATING ACTION TAKEN. SCOPE OF REVIEW: THE SCOPE OF THIS PLAN REVIEW COVERS ARCHITECTURAL, PLUMBING, MECHANICAL, MODEL ENERGY AND ELECTRICAL CODES. ALL CODE REFERENCES ARE TO THE 2000 IRC AND STATE PLUMBING CODE. ALL FEATURES WERE CHECKED ONLY TO THE EXTENT ALLOWED BY THE SUBMITTALS PROVIDED. ALL PORTIONS OF THIS PROJECT ARE ASSUMED TO MEET OR WILL MEET OTHER DEPARTMENTAL REQUIREMENTS, CONDITIONS AND CONCERNS BEFORE PERMIT APPROVAL. GENERAL REQUIREMENTS: 1. ALL PLANS SHALL BE LEGIBLE AND A SCALE NO SMALLER THAN ¼ INCH = 1-FOOT SHALL BE USED FOR ALL FLOOR PLANS, FRAMING PLANS AND ELEVATIONS. DETAILS &CROSS SECTIONS AT A MINIMUM 3/8 INCH = 1-FOOT SCALE. 2. ALL CORRECTIONS AND REVISIONS SHALL BE MADE ON THE ORIGINAL TRACINGS AND TWO NEW SETS OF PRINTS OR (1) SEPIA & (1) BLUE LINE SHALL BE RETURNED ALONG WITH ALL REDLINE PRINTS. 3. PEN OR PENCIL CORRECTIONS ON FINAL PRINTS WILL NOT BE ACCEPTABLE. TO AVOID DELAYS ENSURE ALL CORRECTIONS HAVE BEEN MADE, ARE COMPLETE AND HAVE BEEN COORDINATED ON ALL APPLICABLE DETAILS AND NOTES. 4. LIST THE SQUARE FOOTAGES FOR ALL THE FOLLOWING AREAS SEPARATELY ON THE DRAWINGS: - LIVABLE AREA - GARAGE - PORCH/PATIO COVERS - DECKS 5. ALL ENGINEERS AND ARCHITECTS INVOLVED IN THE DESIGN OF THE STRUCTURE ARE TO SEAL THE RELATED SHEETS OF PLANS, DETAILS AND CALCULATIONS. THIS IS IN ACCORDANCE WITH THE RULES OF THE STATE BOARD OF TECHNICAL REGISTRATION. FOUNDATION PLANS: 1. NOTE ON THE DRAWINGS THE ALLOWABLE SOIL BEARING PRESSURE USED IN THE DESIGN OF THE FOOTINGS, OR STATE THAT THE ASSUMED VALUE OF 1500 PSF IS BEING USED, PER TABLE R401.4.1, A SOILS REPORT IS NOT REQUIRED. IT IS UP TO THE DESIGNER/HOMEBUILDER TO BE AWARE OF THE SOIL AND CONDITIONS OF THE SITE. IF SOIL TESTING HAS BEEN DONE, A COPY OF THE SOILS REPORT SHALL BE SUBMITTED WITH THE CONSTRUCTION PLANS, AND THE FOUNDATION DESIGN SHALL REFLECT THE SOILS REPORTS RECOMMENDATIONS. 2. THE MINIMUM FOOTING WIDTH, PER R403, IS 19" (SEE ALSO B&C/6). 3.PROVIDE A LANDING OUTSIDE THE LAUNDRY EXIT DOOR. FLOOR PLANS: 1. PROVIDE HANDRAILS AT STEPS WITH MORE THAN ONE RISER. 2. NOTE THAT BATHTUB AND SHOWER ENCLOSURES SHALL BE FINISHED PER p2710 WITH CERAMIC TILE, OR A LISTED ENCLOSURE, TO A HEIGHT OF 72" ABOVE THE DRAIN PER R702.4 AND R307.2 3. THE 32" O.C. VERTICALS DOWELED INTO THE EXISTING WALL SHOULD BE AT 24" O.C. TO ACCOMMODATE THE TECH-BLOCK. 4. IDENTIFY CEILING HEIGHTS IN ALL AREAS ON FLOOR PLAN. IF SLOPED CEILING, NOTE AVERAGE HEIGHT. STRUCTURAL PLANS: 1. SPECIFY DESIGN CRITERIA ON PLANS. VALUES FOR FLOOR DEAD LOAD AND LIVE LOAD, ROOF DEAD LOAD AND LIVE LOAD. 2. PROVIDE MANUFACTURER'S CALCULATIONS AND DATA FOR PRE-FAB TRUSSES. TRUSS CALCULATIONS MUST BE SIGNED, DATED AND WET-SEALED BY AN ENGINEER WHO IS REGISTERED IN ARIZONA. TRUSS CALCULATIONS SHALL BE CROSS-REFERENCED TO THE FLOOR PLANS. 3. PROVIDE LINTEL SCHEDULE. 4. PROVIDE TWO COPIES OF THE "TECH-BLOCK" LISTING AND IF MORE THAN ONE THICKNESS IS OFFERED, PLEASE SPECIFY A THICKNESS. IS "TECH-BLOCK" SCREEN GRID OR WAFFLE GRID ? SECTIONS - DETAILS - MISC. NOTES: 1. A&B/6, LEDGER BOLTS NOT IN CONFORMANCE WITH R611.8.2. SEE ALSO FIGURE R606.10(1) 2. PROVIDE ROOF VENTILATION CALCULATIONS AND ILLUSTRATE. PLUMBING PLANS: 1. PROVIDE A PLUMBING FIXTURE SCHEDULE AND TOTAL DEVELOPED LENGTH, INCLUDING BOTH EXISTING AND PROPOSED WATER DISTRIBUTION SYSTEMS. 2. PROVIDE THE SIZE OF THE EXISTING WATER SERVICE LINE AND METER. 3. NOTE ON PLANS THAT TUB / SHOWER COMBINATIONS THAT HAVE INDIVIDUAL CONTROL VALVES SHALL BE OF THE PRESSURE BALANCE OR THERMOSTATIC MIXING VALVE TYPE. ELECTRICAL PLANS: 1. NOTE THAT AT LEAST ONE 20-AMP BRANCH CIRCUIT SHALL BE INSTALLED TO SERVE THE LAUNDRY ROOM, AND THIS CIRCUIT SHALL HAVE NO OTHER OUTLETS, PER E3603.3. 2. WHERE CEILING FANS ARE SHOWN ON THE PLANS, PROVIDE A NOTE INDICATING ONLY APPROVED OUTLET BOXES SHALL BE USED, PER E4001.6. 3. NOTE 8/9, SMOKE DETECTORS SHOULD BE NOT OVER 12" FROM THE CEILING AND NOT LESS THAN 3' FROM A DUCT OPENING. 4. ELECTRICAL SUB-PANELS ARE NOT PERMITTED IN CLOSETS AND REQUIRE WORKING CLEARANCE OF 30" WIDE , 36" DEEP, AND 6'-6" HIGH. 5. ELECTRICAL LOAD CALCULATIONS ARE REQUIRED FOR THE SUB-PANEL. 6. SUBMIT PANEL SCHEDULE SHOWING CIRCUIT AMPACITY, WIRE SIZES, PANEL SIZE AND CIRCUIT NUMBERS. 7. PROVIDE A SMOKE DETECTOR IMMEDIATELY OUTSIDE THE BEDROOM. 8. THE FRONT AND BACK OF DWELLINGS ARE TO HAVE AN EXTERIOR RECEPTACAL. EXISTING? MODEL ENERGY CODE: (REQUIRED FOR THE GUEST HOUSE ADDITION) 1. PROVIDE ENERGY CALCULATIONS PER THE 1998 IECC, OR COMPLY WITH IRC CHAPTER 11. 2. CALL OUT ON THE PLANS THE "R" VALUES OF INSULATION, AS WELL AS THE "U" VALUES OF THE WINDOWS AND DOORS IN CONFORMANCE WITH THE ENERGY CALCULATIONS PROVIDED. IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT YOUR ASSIGNED PLANS EXAMINER: DAVE WITT @ 791-5550 EXT. 1110 I PUT A "SHORT FORM " FOR ADDITIONS IN THE APPLICATION TO MAKE THE ENERGY CALC'S EASIER. |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 06/06/2003 | TAMI ACHONG | OUT TO CUSTOMER | Completed |
| 05/23/2003 | ANGIE SHOFFSTALL | REJECT SHELF | Completed |