Permit Review Detail
Review Status: Completed
Review Details: RESUBMITTAL
Permit Number - T03CM02031
Review Name: RESUBMITTAL
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 08/06/2003 | Robert Sherry | PLUMBING-COMMERCIAL | REVIEW | Denied | 1. Please provide all drawings to scale. Reference Section 302.3, Uniform Administrative Code 1997. Second Request. 2. Provide design to show how the utility services being covered by the new building will be modified. Include information on the materials to be used in this work. Reference Section 302.3, Uniform Administrative Code 1997. 3. Provide calculations to show that the minimum plumbing facilities are provided for the school. Reference Section 2902.1, IBC 2000. 4. Provide dimensions of the scuppers and overflow scuppers along with the supporting calculations. Reference Appendix D, UPC 1994. Second request. |
| 08/06/2003 | ROBERT SHERRY | MECHANICAL-COMMERCIAL | REVIEW | Approved | |
| 08/12/2003 | JIM EGAN | FIRE | REVIEW | Denied | 1. PROVIDE COMPLETE, CORRECT CODE REVIEW CHECKLIST.(OCCUPANCY IS A-2, OCCUPANT LOAD BASED ON 7 SQ. FT. PER OCCUPANT, PANIC HARDWARE REQUIRED, ETC.) 2. SEE SITE COMMENTS. |
| 08/15/2003 | Doug Laakso | BUILDING-COMMERCIAL | REVIEW | Denied | .. T03CM02031 .. 3302 N FLOWING WELLS RD .. 2ND REVIEW .. DGL .. 8/25/03 . ............. .. S1) SEE PRIOR COMMENT #1. PLEASE PROVIDE COMPLETE AND PROPER INFORMATION. ........... .. S2) SEE PRIOR COMMENT #2. ADDRESS UTILITIES NOTED ON #A00 UNDER PLUMBING , EXPLAIN. ALSO PROVIDE COPY OF GEOTECNICAL /SOILS REPORT NOTED ON DWG #A00. ..................... .. S3) SEE PRIOR COMMENT #3. COMPLY WITH ITEMS #1-10 ON SEALED AND SIGNED DRAWING. ............. .. S4) SEE PRIOR COMMENT #5. SHOW CLASSIFICATION OF EXISTING BUILDINGS ON SITE. TYPE I CONSTRUCTION REQUIRES FIRE RATINGS, PER TABLE 601 & 602, SHOW HOW THIS IS ACCOMPLISHED , PROVIDE DETAIL AND COPIES OF FIRE LISTINGS , ON DRAWINGS. ........................................... ................ .. S5) SEE PRIOR COMMENT #6. PROVIDE COPY OF OFFICIAL ADDRESS SLIP FROM PIMA COUNTY ADDRESSING, FOR THIS BUILDING. SHOW ,ON DRAWINGS , WHERE COMPLYING ADDRESS IS PLACED ON BUILDING. PROVIDE IBC CODE SUMMARY OF INFORMATION ON THE DRAWINGS. ................................ ..S6) SEE PRIOR COMMENT #7 . CLARIFY TYPE OF CONSTRUCTION I-A OR I-B. SHOW HOW FIRE RATINGS ARE ACCOMPLISHED AND MAINTAINED PER TABLES 601 & 602. PROVIDE FIRE -RATED DETAILS AND FIRE LISTINGS ON DRAWINGS. ............................................................. .. S7) SEE PRIOR COMMENT #8. CAFETERIA ( DINING ) = ONE OCCUPANT / 15 SF, MEETING ROOM W/O FIXED SEATING = ONE OCCUPANT / 7 SF : ............................. . ....... 1466 SF BUILDING AS CAFETERIA : OL = 97 ............ ....... 1466 SF BUILDING AS MTG ROOM : OL 205 ............ .. S8) SEE PRIOR COMMENT #9. CLARIFY AND JUSTIFY AREA AND TYPE OF CONSTRUCTION. ............................. .. S9) SEE PRIOR COMMENT #10. EXPLAIN EXTERIOR WALL FIRE-RATING ON DRAWINGS. ................................ .. S10) SEE PRIOR COMMENT #11 . PLEASE INDICATE ON DRAWINGS. ................................................................... .. S11) SEE PRIOR COMMENT #12. EXPLAIN ON DRAWINGS ACCESSIBILITY TO PUBLIC WAY AND PARKING. ....................................................................... .. S12) SEE PRIOR COMMENT #13. PROVIDE INFORMATION REQUESTED ON DRAWINGS. ................... .. S13) SEE PRIOR COMMENT #14. VERIFY EXIT DOORS ARE NOT PROVIDED WITH ALOCK OR LATCH OTHER THAN PANIC HARDWARE PER IBC SEC 1003.3.1.9. .......... .. S14) SEE PRIOR COMMENT #15. THE LOCATION OF THE ACCESSIBILE PARKING SPACES DOES NOT APPEAR TO COMPLY WITH IBC SEC 1106.5, PLEASE RELOCATE AND FULLY DETAIL TO SHOW COMPLIANCE . ALSO ADDRESS REMAINDER OF ACCESSIBILE ITEMS LISTED IN SECTION #11 OF IBC. .................................................... .. ..... .. .. S15) SEE PRIOR COMMENT #16. PROVIDE SHOP DRAWINGS FOR WALL SYSTEM PER NOTE #25 OF PRIOR COMMENTS. .................................................................. .. S16) SEE PRIOR COMMENT #17. WHERE ARE CALCULATIONS? ............................................................ .. S17) SEE PRIOR COMMENT #18. PROVIDE CALCULATIONS FOR MINIMUM PLUMBING FIXTURES PER TABLE 29, SHOW CONFORMANCE WITH CHAPTER 11 OF IBC AND ANSI A117.1- 1998 ed ON DRAWINGS. ................ .. S18) SEE PRIOR COMMENT #19. EXPLAIN. .................. .. S19) SEE PRIOR COMMENT #20. SHOW IN CALCULATIONS AND ON DRAWINGS. SEE WHAT ATTACHMENT? ............................................................... .. S20) SEE PRIOR COMMENT #21. NO ATTACHMENT SUBMITTED. ................................................................... .. S21) SEE PRIOR COMMENT #22. PROVIDE CALCS AND DRAWINGS W/ EXPLANATION. ........................................ . ............. .. S22) SEE PRIOR COMMENT #23. PROVIDE STRUCTURAL CALCULATIONS AND DETAILS ON DRAWINGS. DRAWING A7 NOT ACCEPTABLE, W/O STRUCTURAL CALCULATIONS. .. S23) SEE PRIOR COMMENT #24. PROVIDE COMPLETE INSPECTION PROGRAM, SEE PARAGRAPH " BEFORE A PERMIT CAN BE ISSUED:" PORTION OF SPECIAL INSPECTION AND TESTING AGREEMENT SUBMITTED...... .. S24) SEE PRIOR COMMENT #25. PROVIDE COPY OF SOILS REPORT, PROVIDE SOIL DETAILS/REQUIREMENTS ON DRAWINGS. SPECIAL INSPECTION REQUIRED FOR SOILS : 1. SITE PREPARATION OF THE BUILDING ........... ........... 2. FOUNDATION EXCAVATION AND COMPACTION. |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 08/26/2003 | LISA LESNY | OUT TO CUSTOMER | Completed |
| 08/26/2003 | ANGIE SHOFFSTALL | REJECT SHELF | Completed |