Permit Review Detail
Review Status: Completed
Review Details: RESIDENTIAL BLDG/WWM
Permit Number - T03CM01952
Review Name: RESIDENTIAL BLDG/WWM
Review Status: Completed
Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
---|---|---|---|---|---|
11/06/2003 | MELISSA POULIN | WWM | REVIEW | Approved | |
12/24/2003 | PIMA COUNTY | BUILDING-RESIDENTIAL | REVIEW | Denied | Structural: Sheet a0: concrete notes 1 indicates footings with 3000 psi concrete. 3000 psi concrete requires a special inspection. Provide a special inspection certificate to Pima County Bldg Codes plan review with the upper 2/3rd completed. In order to complete the structural review provide the structural calculations that accompany the engineers of records seal on sheets a2 and a3. Questions? Daniel E. Ice , 520-740-6490 Mechanical: City of Tucson subscribes to the 2000 IRC. change any/all uniform code refrences to 2000 IRC references. See mechanical general notes. A 5 ton unit produces a nominal (400 cfm/ton) (5tons) = 2,000 cfm; however, the floor plan diffuser pattern distributes 2,375 cfm. Either make the specified cfm and distributed cfm equal or specify unit output at 2,375 cfm in schedule. Plumbing: Cold water ingress as shown on site plan and plumbing plan shall agree. Dryer input is 35 cfh in schedule and 65 cfh on floor plan. Please resolve. Electrical: Comply section 210-52(e), '99 NEC circuit #27 - comply 210-52(b) '99 NEC |
Final Status
Task End Date | Reviewer's Name | Type of Review | Description |
---|---|---|---|
12/26/2003 | TAMI ACHONG | OUT TO CUSTOMER | Completed |
12/24/2003 | ANGIE SHOFFSTALL | REJECT SHELF | Completed |