Permit Number: T03CM01898
Parcel: 137060580

Address:
542 W ALASKA ST

Review Status: Completed

Review Details: SITE

Permit Number - T03CM01898
Review Name: SITE
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
01/20/2004 James Tate ENGINEERING REVIEW Approved
01/26/2004 JOE LINVILLE LANDSCAPE REVIEW Denied 1) Identify the materials used to provide screening for the refuse container storage area. Chain link fencing alone does not meet the minimum standards. DS 2-07.2.2.A.3, LUC 3.7.3.7.D.3.

2) Per LUC 3.7.3.2.B screens along a street frontage must be located on the development side of the street landscape border so that they do not obstruct the view of the street
landscape border from the street. Revise the plans as necessary to provide a screen along the Alaska Street frontage behind or at the back of the street landscape border.

3) Revise the landscape plan to locate Chihuahuan sage outside of the sight visibility triangles. This plant typically grows too large to comply with the height restrictions of
DS 2-06.3.7.B.1.

4) Per LUC 3.7.4.5.A "A water-conserving irrigation system is required for all new landscape plantings." The hand irrigation
proposed on the plans does not meet the water conservation standards of DS 2-06.5.0.

All plant material is required to be irrigated with drip irrigation or low flow bubblers and the system must also be equipped with an automatic controller. DS 2-06.5.4
01/27/2004 PETER MCLAUGHLIN HANDICAP-SITE REVIEW Approved
01/27/2004 Peter McLaughlin ZONING REVIEW Approved

Final Status

Task End Date Reviewer's Name Type of Review Description
01/29/2004 DELMA ROBEY OUT TO CUSTOMER Completed