Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit Number: T03CM01893
Parcel: 123172140

Review Status: Completed

Review Details: 3RD PARTY REVIEW-RESIDENTIAL

Permit Number - T03CM01893
Review Name: 3RD PARTY REVIEW-RESIDENTIAL
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
05/02/2003 EROSE1 WWM REVIEW Needs Review
05/02/2003 STANTEC 3RD PARTY REVIEW-COMMERCIAL REVIEW Denied ARCHITECTURAL COMMENTS
Sheet 1.0
1. The area of the 17' - 2" x 5' - 0" porch in the area calculations for lot coverage is 86 s.f.

Sheet 2.0
1. Western One Kote stucco system is specified in general note 1. San Kote stucco system is specified in wall section 3/5.0. Please clarify.

2. R-19 insulation is specified in general note 14 for all exterior walls. Wall section 3/5.0 specifies R-13. Please clarify.

3. R-30 insulation is specified in general note 14 for the roof. Wall section 3/5.0 specifies R-38.
Please clarify.

4. Dimensions are missing from the floor plan. See redlines.

5. Show on the plan where the alternate braced wall panel keynoted as wall type 3 occurs.
Ref. R602.10.6

Sheet 3.0
1. Detail 4/3.0 appears to occur in foundation construction at the sliding glass door landings. Please reference the detail where it occurs on the plan.

2. There appears to be a drafting error at the north end of the foundation plan. Detail references and linework are missing.

3. The dimension between the structures does not agree with the site plan. Please clarify.

STRUCTURAL COMMENTS
Sheet 3.0
1. The minimum width for concrete footings (assuming 1,500 psf of soil bearing pressure) to be used with 2 story conventional light frame construction is 19". Please revise footing details. Refs. Table R403.1, Table 401.4.1.

PLUMBING COMMENTS
Sheet 1.0
1. Please specify Schedule 40 PVC DWV for the 4" waste line. Ref. UPC 701.

2. The water service entrance shown on Sheet 6.0 conflicts with the site utility lines shown on Sheet 1.0. Please clarify.

3. Two temperature and pressure relief points of termination are shown. Please clarify.

Sheet 6.0
1. The fixture unit schedule indicates two clothes washers. Only one clothes washr is shown on the plan. Revise as necessary.

2. Provide the pressure available at the service to determine the correct building supply line size. Ref. UPC Table 6-4.


MECHANICAL COMMENTS
Sheet 6.0
1. Note the location and point of termination for the range hood. Ref. M1502.

ELECTRICAL COMMENTS
Sheet 7.0
1. Circuits 22 and 24 described as stacked W/D do not appear to have been used. Please clarify.
ENERGY COMMENTS
General
1. Coordinate with architectural comments 2 and 3 for Sheet 2.0 regarding the discrepancies in the R-values for the exterior wall and roof insulation. Ref. Table N1102.1.
05/02/2003 EROSE1 NPPO REVIEW Needs Review

Final Status

Task End Date Reviewer's Name Type of Review Description
05/02/2003 ELAINE ROSE OUT TO CUSTOMER Completed